TY - JOUR A1 - Xia, Bingqing A1 - Wang, Fengyan A1 - Friedrich-Rust, Mireen A1 - Zhou, Fang A1 - Zhu, Jianhui A1 - Yang, Hua A1 - Ruan, Weishan A1 - Zeng, Zhirong T1 - Feasibility and efficacy of transient elastography using the XL probe to diagnose liver fibrosis and cirrhosis : a meta-analysis T2 - Medicine N2 - Background: Transient elastography (TE) has been validated as an effective noninvasive tool for the assessment of liver fibrosis. The XL probe is a new probe that was initially designed for use in patients with obesity. A meta-analysis was performed to assess the feasibility and efficacy of TE using the XL probe. Methods: In September 2016, we systematically searched the PubMed and Science Direct search engines. The feasibility of TE was evaluated based on the failure rate and the results of the unreliable liver stiffness measurement (LSM). The efficacy of TE was measured using sensitivity, specificity, and summary receiver-operating characteristic as measures/indices assessed in different stages of fibrosis. Heterogeneity was measured using the chi-squared test and the Q-statistic. We used the 95% confidence interval (95% CI) as an effect measure. Results: We included 8 studies in the meta-analysis. When the XL was compared to the M probe, the former showed a lower risk of failure rate [relative risk (RR) 0.24, 95% CI 0.14–0.38]. In patients with a body mass index ≥30 kg/m2, the XL probe showed a statistically significantly lower risk of failure rate (RR 0.16, 95% CI 0.08–0.32) but no significant improvement (RR 0.76, 95% CI 0.50–1.16) in the unreliable LSM result. In patients showing liver fibrosis stage ≥F2, the XL probe showed a sensitivity of 0.56 (95% CI 0.39–0.72), specificity of 0.71 (95% CI 0.61–0.79), and an area under the curve (AUC) of 0.71. The results observed in patients with liver fibrosis stage F4 were more promising with a sensitivity of 0.84 (95% CI 0.76–0.90), specificity of 0.78 (95% CI 0.70–0.84), and an AUC of 0.88. Conclusion: TE using the XL probe demonstrates significant diagnostic utility in patients with liver fibrosis and is likely to be more reliable than the M probe in patients with obesity. Large prospective multicenter studies are, however, necessary to establish the new cut-off values to be used for the XL probe in patients with obesity. KW - liver fibrosis KW - obese KW - transient elastography KW - XL probe Y1 - 2018 UR - http://publikationen.ub.uni-frankfurt.de/frontdoor/index/index/docId/47675 UR - https://nbn-resolving.org/urn:nbn:de:hebis:30:3-476754 SN - 1536-5964 SN - 0025-7974 N1 - Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. VL - 97 IS - 39, e11816 SP - 1 EP - 8 PB - Lippincott Williams & Wilkins CY - Baltimore, Md. ER -