Differences between mechanically stable and unstable chronic ankle instability subgroups when examined by arthrometer and FAAM-G

  • Background: The objective measurement of the mechanical component and its role in chronic ankle instability is still a matter of scientific debate. We analyzed known group and diagnostic validity of our ankle arthrometer. Additionally, functional aspects of chronic ankle instability were evaluated in relation to anterior talar drawer. Methods: By manual stress testing, 41 functionally unstable ankles were divided as mechanically stable (n = 15) or mechanically unstable (n = 26). Ankle laxity was quantified using an ankle arthrometer. Stiffness values from the load displacement curves were calculated between 40 and 60 N. Known group validity and eta2 were established by comparing manual and arthrometer testing results. Diagnostic validity for the ankle arthrometer was determined by a 2 × 2 contingency table. The functional ankle instability severity was quantified by the German version of the Foot and Ankle Ability Measure (FAAM-G). Stiffness (40–60 N) and FAAM-G values were correlated. Results: Mechanically unstable ankles had lower 40–60 N stiffness values than mechanically stable ankles (p = 0.006 and <0.001). Eta for the relation between manual and arthrometer anterior talar drawer testing was 0.628. With 5.1 N/mm as cut-off value, accuracy, sensitivity, and specificity were 85%, 81%, and 93%, respectively. The correlation between individual 40–60 N arthrometer stiffness values and FAAM-G scores was r = 0.286 and 0.316 (p = 0.07 and 0.04). Conclusions: In this investigation, the ankle arthrometer demonstrated a high diagnostic validity for the determination of mechanical ankle instability. A clear interaction between mechanical (ankle arthrometer) and functional (FAAM-G) measures could not be demonstrated.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Heinz Lohrer, Tanja Nauck, Dominic Gehring, Sabrina Wissler, Bela Braag, Albert Gollhofer
URN:urn:nbn:de:hebis:30:3-372415
DOI:https://doi.org/10.1186/s13018-015-0171-2
ISSN:1749-799X
Pubmed Id:https://pubmed.ncbi.nlm.nih.gov/25890204
Parent Title (English):Journal of orthopaedic surgery and research
Publisher:BioMed Central
Place of publication:London
Document Type:Article
Language:English
Date of Publication (online):2015/03/08
Date of first Publication:2015/03/08
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2015/04/25
Tag:Ankle arthrometer; Chronic ankle instability; FAAM; Functional ankle instability; Mechanical ankle instability
Volume:10
Issue:32
Page Number:9
Note:
Copyright © Lohrer et al.; licensee BioMed Central. 2015. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
HeBIS-PPN:369050436
Institutes:Medizin / Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - Namensnennung 4.0