Ultrafast cone-beam computed tomography : a comparative study of imaging protocols during image-guided therapy procedure

  • Objective: To evaluate two ultrafast cone-beam CT (UF-CBCT) imaging protocols with different acquisition and injection parameters regarding image quality and required contrast media during image-guided hepatic transarterial chemoembolization (TACE). Methods: In 80 patients (male: 46, female: 34; mean age: 56.8 years; range: 33–83) UF-CBCT was performed during TACE for intraprocedural guidance. Imaging was performed using two ultrafast CBCT acquisition protocols with different acquisition and injection parameters (imaging protocol 1: acquisition time 2.54 s, and contrast 6 mL with 3 s delay; imaging protocol 2: acquisition time 2.72 s, and contrast 7 mL with 6 s delay). Image evaluation was performed with both qualitative and quantitative methods. Contrast injection volume and dose parameters were compared using values from the literature. Results: Imaging protocol 2 provided significantly better (P < 0.05) image quality than protocol 1 at the cost of slightly higher contrast load and patient dose. Imaging protocol 1 provided good contrast perfusion but it mostly failed to delineate the tumors (P < 0.05). On the contrary, imaging protocol 2 showed excellent enhancement of hepatic parenchyma, tumor, and feeding vessels. Conclusion: Tumor delineation, visualization of hepatic parenchyma, and feeding vessels are clearly possible using imaging protocol 2 with ultrafast CBCT imaging. A reduction of required contrast volume and patient dose were achieved due to the ultrafast CBCT imaging.

Download full text files

Export metadata

Metadaten
Author:Jijo Paul, Annamma Chacko, Mohammad Farhang, Shahram Kamali, Mohsen Tavanania, Thomas J. VoglORCiDGND, Bita Panahi
URN:urn:nbn:de:hebis:30:3-393995
DOI:https://doi.org/10.1155/2015/467850
ISSN:2314-6141
Parent Title (English):BioMed research international
Publisher:Hindawi
Place of publication:New York
Document Type:Article
Language:English
Year of Completion:2015
Year of first Publication:2015
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2016/02/04
Volume:2015
Issue:Article ID 467850
Page Number:9
First Page:1
Last Page:8
Note:
Copyright © 2015 Jijo Paul  et al. This is an open access article distributed under the Creative Commons Attribution License http://creativecommons.org/licenses/by/3.0/ , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
HeBIS-PPN:378141252
Institutes:Medizin / Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - Namensnennung 3.0