Intercomparing different devices for the investigation of ice nucleating particles using Snomax® as test substance

  • Seven different instruments and measurement methods were used to examine the immersion freezing of bacterial ice nuclei from Snomax® (hereafter Snomax), a product containing ice active protein complexes from non-viable Pseudomonas syringae bacteria. The experimental conditions were kept as similar as possible for the different measurements. Of the participating instruments, some examined droplets which had been made from suspensions directly, and the others examined droplets activated on previously generated Snomax particles, with particle diameters of mostly a few hundred nanometers and up to a few micrometers in some cases. Data were obtained in the temperature range from −2 to −38 °C, and it was found that all ice active protein complexes were already activated above −12 °C. Droplets with different Snomax mass concentrations covering 10 orders of magnitude were examined. Some instruments had very short ice nucleation times down to below 1 s, while others had comparably slow cooling rates around 1 K min−1. Displaying data from the different instruments in terms of numbers of ice active protein complexes per dry mass of Snomax, nm, showed that within their uncertainty the data agree well with each other as well as to previously reported literature results. Two parameterizations were taken from literature for a direct comparison to our results, and these were a time dependent approach based on a contact angle distribution Niedermeier et al. (2014) and a modification of the parameterization presented in Hartmann et~al.~(2013) representing a time independent approach. The agreement between these and the measured data were good, i.e. they agreed within a temperature range of 0.6 K or equivalently a range in nm of a factor of 2. From the results presented herein, we propose that Snomax, at least when carefully shared and prepared, is a suitable material to test and compare different instruments for their accuracy of measuring immersion freezing.

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Heike WexORCiDGND, Stefanie Augustin-Bauditz, Yvonne BooseORCiDGND, Carsten Budke, Joachim CurtiusORCiD, Karoline Diehl, Axel Dreyer, Fabian FrankORCiDGND, Susan HartmannORCiDGND, Naruki HiranumaORCiDGND, Evelyn JantschORCiD, Zamin A. KanjiORCiDGND, Alexei KiselevORCiDGND, Thomas KoopORCiD, Ottmar MöhlerORCiDGND, Dennis NiedermeierORCiDGND, Björn Nillius, Michael Rösch, Diana RoseGND, C. Schmidt, Isabelle SteinkeORCiDGND, Frank StratmannORCiDGND
URN:urn:nbn:de:hebis:30:3-372517
DOI:https://doi.org/10.5194/acpd-14-22321-2014
ISSN:1680-7375
ISSN:1680-7367
Titel des übergeordneten Werkes (Englisch):Atmospheric chemistry and physics / Discussions
Verlag:European Geosciences Union
Verlagsort:Katlenburg-Lindau
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Veröffentlichung (online):01.09.2014
Datum der Erstveröffentlichung:01.09.2014
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:22.04.2015
Jahrgang:14
Seitenzahl:64
Erste Seite:22321
Letzte Seite:22384
Bemerkung:
© Author(s) 2014. This work is distributed under the Creative Commons Attribution 3.0 License.
HeBIS-PPN:369071522
Institute:Geowissenschaften / Geographie / Geowissenschaften
DDC-Klassifikation:5 Naturwissenschaften und Mathematik / 55 Geowissenschaften, Geologie / 550 Geowissenschaften
Sammlungen:Universitätspublikationen
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung 3.0