• Treffer 2 von 18
Zurück zur Trefferliste

Potential of high dimensional radiomic features to assess blood components in intraaortic vessels in non-contrast CT scans

  • Background: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. Methods: One hundred patients (median age, 69 years; range, 19–94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). Results: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). Conclusions: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment.

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Scherwin MahmoudiGND, Simon MartinORCiDGND, Jörg AckermannORCiDGND, Yauheniya Zhdanovich, Ina KochORCiD, Thomas J. VoglORCiDGND, Moritz Hans Ernst AlbrechtORCiDGND, Lukas Fabian LengaORCiDGND, Simon BernatzORCiDGND
URN:urn:nbn:de:hebis:30:3-626224
DOI:https://doi.org/10.1186/s12880-021-00654-9
ISSN:1471-2342
Titel des übergeordneten Werkes (Englisch):BMC medical imaging
Verlag:BioMed Central
Verlagsort:London
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Veröffentlichung (online):12.08.2021
Datum der Erstveröffentlichung:12.08.2021
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:02.11.2021
Freies Schlagwort / Tag:Anemia; Artificial intelligence; Blood; CT; Radiomics
Jahrgang:21
Ausgabe / Heft:art. 123
Seitenzahl:10
Erste Seite:1
Letzte Seite:10
Bemerkung:
The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
Open Access funding enabled and organized by Projekt DEAL.
HeBIS-PPN:489040624
Institute:Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung 4.0