• Treffer 7 von 120
Zurück zur Trefferliste

Effect of using different U/S probe Standoff materials in image geometry for interventional procedures : the example of prostate

  • PURPOSE: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established water-bath based quality assurance (QA) procedures is presented. MATERIAL AND METHODS: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/S probe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one of the following: 40 ml of Endosgel(®), Instillagel(®), Ultraschall gel or Space OAR™ gel. The differences between images were recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissue equivalent ultrasound prostate phantom - Model number 053 (CIRS Inc., Norfolk, VA, USA). RESULTS: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needle shift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate in our case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimation of the dose. On the other hand, Instillagel(®) and Space OAR™ "shrinks" objects in an ultrasound image for 0.65 mm and 0.40 mm, respectively. CONCLUSIONS: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTV and OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostate brachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used for accurate simulation of real conditions of transrectal ultrasound imaging.

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Stefanos Diamantopoulos, Natasa Milickovic, Saeed Butt, Zaira Katsilieri, Vasiliki Kefala, Pawel Zogal, George Sakas, Dimos BaltasGND
URN:urn:nbn:de:hebis:30:3-317169
DOI:https://doi.org/10.5114/jcb.2011.26472
ISSN:2081-2841
ISSN:1689-832X
Pubmed-Id:https://pubmed.ncbi.nlm.nih.gov/23346130
Titel des übergeordneten Werkes (Englisch):Journal of contemporary brachytherapy
Verlag:Termedia
Verlagsort:Poznan
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Veröffentlichung (online):31.12.2011
Datum der Erstveröffentlichung:31.12.2011
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:04.10.2013
Freies Schlagwort / Tag:image distortion; needle displacement; prostate brachytherapy; ultrasound
Jahrgang:3
Ausgabe / Heft:4
Seitenzahl:11
Erste Seite:209
Letzte Seite:219
Bemerkung:
Copyright © 2011 Termedia This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
HeBIS-PPN:353304425
Institute:Medizin / Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung-Nicht kommerziell 3.0