• Treffer 1 von 27
Zurück zur Trefferliste

Feasibility and efficacy of transient elastography using the XL probe to diagnose liver fibrosis and cirrhosis : a meta-analysis

  • Background: Transient elastography (TE) has been validated as an effective noninvasive tool for the assessment of liver fibrosis. The XL probe is a new probe that was initially designed for use in patients with obesity. A meta-analysis was performed to assess the feasibility and efficacy of TE using the XL probe. Methods: In September 2016, we systematically searched the PubMed and Science Direct search engines. The feasibility of TE was evaluated based on the failure rate and the results of the unreliable liver stiffness measurement (LSM). The efficacy of TE was measured using sensitivity, specificity, and summary receiver-operating characteristic as measures/indices assessed in different stages of fibrosis. Heterogeneity was measured using the chi-squared test and the Q-statistic. We used the 95% confidence interval (95% CI) as an effect measure. Results: We included 8 studies in the meta-analysis. When the XL was compared to the M probe, the former showed a lower risk of failure rate [relative risk (RR) 0.24, 95% CI 0.14–0.38]. In patients with a body mass index ≥30 kg/m2, the XL probe showed a statistically significantly lower risk of failure rate (RR 0.16, 95% CI 0.08–0.32) but no significant improvement (RR 0.76, 95% CI 0.50–1.16) in the unreliable LSM result. In patients showing liver fibrosis stage ≥F2, the XL probe showed a sensitivity of 0.56 (95% CI 0.39–0.72), specificity of 0.71 (95% CI 0.61–0.79), and an area under the curve (AUC) of 0.71. The results observed in patients with liver fibrosis stage F4 were more promising with a sensitivity of 0.84 (95% CI 0.76–0.90), specificity of 0.78 (95% CI 0.70–0.84), and an AUC of 0.88. Conclusion: TE using the XL probe demonstrates significant diagnostic utility in patients with liver fibrosis and is likely to be more reliable than the M probe in patients with obesity. Large prospective multicenter studies are, however, necessary to establish the new cut-off values to be used for the XL probe in patients with obesity.
Metadaten
Verfasserangaben:Bingqing Xia, Fengyan Wang, Mireen Friedrich-RustORCiDGND, Fang Zhou, Jianhui Zhu, Hua Yang, Weishan Ruan, Zhirong Zeng
URN:urn:nbn:de:hebis:30:3-476754
DOI:https://doi.org/10.1097/MD.0000000000011816
ISSN:1536-5964
ISSN:0025-7974
Pubmed-Id:https://pubmed.ncbi.nlm.nih.gov/30278481
Titel des übergeordneten Werkes (Englisch):Medicine
Verlag:Lippincott Williams & Wilkins
Verlagsort:Baltimore, Md.
Sonstige beteiligte Person(en):Ludovico Abenavoli
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Fertigstellung:2018
Jahr der Erstveröffentlichung:2018
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:09.10.2018
Freies Schlagwort / Tag:XL probe; liver fibrosis; obese; transient elastography
Jahrgang:97
Ausgabe / Heft:39, e11816
Seitenzahl:8
Erste Seite:1
Letzte Seite:8
Bemerkung:
Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
HeBIS-PPN:439194431
Institute:Medizin / Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Lizenz (Englisch):License LogoCreative Commons - Namensnennung-Nicht kommerziell 4.0