Refine
Year of publication
- 2011 (2) (remove)
Document Type
- Master's Thesis (2) (remove)
Language
- English (2) (remove)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- (n (1)
- Beryllium-7 (1)
- FRANZ (1)
- Lithium-7 (1)
- Monte-Carlo-Simulation (1)
- Neutronenquelle (1)
- Neutronenspektrum (1)
- Phasenraum (1)
- gamma) Reaktionen (1)
- gamma) reactions (1)
Institute
- Physik (2)
The ALICE Time Projection Chamber (TPC) is the main tracking detector of ALICE which was designed to perform well at multiplicities of up to 20000 charged primary and secondary tracks emerging from Pb-Pb collisions. Successful operation of such a large and complex detector requires an elaborate calibration and commissioning. The main goal for the calibration procedures is to provide the information needed for the offline software for the reconstruction of the particle tracks with sufficient precision so that the design performance can be achieved. For a precise reconstruction of particle tracks in the TPC, the calibration of the drift velocity, which in conjunction with the drift time provides the z position of the traversing particles, is essential. In this thesis, an online method for the calibration of the drift velocity is presented. It uses the TPC Laser System which generates 336 straight tracks within the active volume of the TPC. A subset of these tracks, showing sufficiently small distortions, is used in the analysis. The resulting time dependent drift velocity correction parameters are entered into a database and provide start values for the offline reconstruction chain of ALICE. Even though no particle tracking information is used, the online drift velocity calibration is in agreement with the full offline calibration including tracking on the level of about 2 x 10 exp (-4). In chapter 2, a short overview of the ALICE detector, as well as the data taking model of the ALICE, is given. In chapter 3, the TPC detector is described in detail. Lastly in chapter 4, the online drift velocity calibration method is presented, together with a detailed description of the TPC laser system.
As a part of this thesis, a Monte Carlo-based code has been developed capable of simulating the transition of proton beam properties to neutron beam properties as it occurs in the Li-7(p, n)Be-7 reaction. It is able to reproduce not only the angle-integrated energy distributions but it is also capable of predicting the angle-dependent neutron spectra as measured at Forschungszentrum Karlsruhe (Karlsruhe, Germany) and Physikalisch-Technische Bundesanstalt (Braunschweig, Germany). Since the code retains all three spatial dimensions as well as all three velocity dimensions, it provides very detailed information on the neutron beam. The resulting data can aid in many different aspects, for example it can be used in shielding construction, or for lithium target design. In this work, the code is used to predict the neutron beam properties expected at the Frankfurt Neutron Source at Stern-Gerlach-Zentrum (FRANZ) facility. For different proton beam energies, the neutron distribution in x/p_x, y/p_y, and z/p_z is shown as well as a Mollweide projection, which illustrates the kinematic collimation effect that limits the neutron cone opening angle to less than 180 degree.