Refine
Year of publication
Document Type
- Article (53)
- Preprint (2)
- Conference Proceeding (1)
Language
- English (56)
Has Fulltext
- yes (56)
Is part of the Bibliography
- no (56)
Keywords
- 140Ce (1)
- MACS (1)
- capture (1)
- cerium (1)
- cross-section (1)
- health related quality of life (1)
- hepatitis C (1)
- n_TOF (1)
- neutron (1)
- nucleosynthesis (1)
Institute
- Physik (52)
- Medizin (3)
- Biochemie, Chemie und Pharmazie (1)
Background: High baseline levels of IP-10 predict a slower first phase decline in HCV RNA and a poor outcome following interferon/ribavirin therapy in patients with chronic hepatitis C. Several recent studies report that single nucleotide polymorphisms (SNPs) adjacent to IL28B predict spontaneous resolution of HCV infection and outcome of treatment among HCV genotype 1 infected patients. Methods and Findings: In the present study, we correlated the occurrence of variants at three such SNPs (rs12979860, rs12980275, and rs8099917) with pretreatment plasma IP-10 and HCV RNA throughout therapy within a phase III treatment trial (HCV-DITTO) involving 253 Caucasian patients. The favorable SNP variants (CC, AA, and TT, respectively) were associated with lower baseline IP-10 (P = 0.02, P = 0.01, P = 0.04) and were less common among HCV genotype 1 infected patients than genotype 2/3 (P<0.0001, P<0.0001, and P = 0.01). Patients carrying favorable SNP genotypes had higher baseline viral load than those carrying unfavorable variants (P = 0.0013, P = 0.029, P = 0.0004 respectively). Among HCV genotype 1 infected carriers of the favorable C, A, or T alleles, IP-10 below 150 pg/mL significantly predicted a more pronounced reduction of HCV RNA from day 0 to 4 (first phase decline), which translated into increased rates of RVR (62%, 53%, and 39%) and SVR (85%, 76%, and 75% respectively) among homozygous carriers with baseline IP-10 below 150 pg/mL. In multivariate analyses of genotype 1-infected patients, baseline IP-10 and C genotype at rs12979860 independently predicted the first phase viral decline and RVR, which in turn independently predicted SVR. Conclusions: Concomitant assessment of pretreatment IP-10 and IL28B-related SNPs augments the prediction of the first phase decline in HCV RNA, RVR, and final therapeutic outcome.
Background: Interferon and ribavirin therapy for chronic hepatitis C virus (HCV) infection yields sustained virological response (SVR) rates of 50–80%. Several factors such as non-1 genotype, beneficial IL28B genetic variants, low baseline IP-10, and the functionality of HCV-specific T cells predict SVR. With the pending introduction of new therapies for HCV entailing very rapid clearance of plasma HCV RNA, the importance of baseline biomarkers likely will increase in order to tailor therapy. CD26 (DPPIV) truncates the chemokine IP-10 into a shorter antagonistic form, and this truncation of IP-10 has been suggested to influence treatment outcome in patients with chronic HCV infection patients. In addition, previous reports have shown CD26 to be a co-stimulator for T cells. The aim of the present study was to assess the utility of CD26 as a biomarker for treatment outcome in chronic hepatitis C and to define its association with HCV-specific T cells.
Methods: Baseline plasma from 153 genotype 1 and 58 genotype 2/3 infected patients enrolled in an international multicenter phase III trial (DITTO-HCV) and 36 genotype 1 infected patients participating in a Swedish trial (TTG1) were evaluated regarding baseline soluble CD26 (sCD26) and the functionality of HCV-specific CD8+ T cells.
Results: Genotype 1 infected patients achieving SVR in the DITTO (P = 0.002) and the TTG1 (P = 0.02) studies had lower pretreatment sCD26 concentrations compared with non-SVR patients. Sixty-five percent of patients with sCD26 concentrations below 600 ng/mL achieved SVR compared with 39% of the patients with sCD26 exceeding 600 ng/mL (P = 0.01). Patients with sCD26 concentrations below 600 ng/mL had significantly higher frequencies of HCV-specific CD8+ T cells (P = 0.02).
Conclusions: Low baseline systemic concentrations of sCD26 predict favorable treatment outcome in chronic HCV infection and may be associated with higher blood counts of HCV-specific CD8+ T cells.
An accurate measurement of the 140Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140Ce Maxwellian-averaged cross-section.
Neutron capture on 241Am plays an important role in the nuclear energy production and also provides valuable information for the improvement of nuclear models and the statistical interpretation of the nuclear properties. A new experiment to measure the 241Am(n, γ) cross section in the thermal region and the first few resonances below 10 eV has been carried out at EAR2 of the n_TOF facility at CERN. Three neutron-insensitive C6D6 detectors have been used to measure the neutron-capture gamma cascade as a function of the neutron time of flight, and then deduce the neutron capture yield. Preliminary results will be presented and compared with previously obtained results at the same facility in EAR1. In EAR1 the gamma-ray background at thermal energies was about 90% of the signal while in EAR2 is up to a 25 factor much more favorable signal to noise ratio. We also extended the low energy limit down to subthermal energies. This measurement will allow a comparison with neutron capture measurements conducted at reactors and using a different experimental technique.
Background: Hepatitis C decreases health related quality of life (HRQL) which is further diminished by antiviral therapy. HRQL improves after successful treatment. This trial explores the course of and factors associated with HRQL in patients given individualized or standard treatment based on early treatment response (Ditto-study).
Methods: The Short Form (SF)-36 Health Survey was administered at baseline (n = 192) and 24 weeks after the end of therapy (n = 128).
Results: At baseline HRQL was influenced by age, participating center, severity of liver disease and income. Exploring the course of HRQL (scores at follow up minus baseline), only the dimension general health increased. In this dimension patients with a relapse or sustained response differed from non-responders. Men and women differed in the dimension bodily pain. Treatment schedule did not influence the course of HRQL.
Conclusions: Main determinants of HRQL were severity of liver disease, age, gender, participating center and response to treatment. Our results do not exclude a more profound negative impact of individualized treatment compared to standard, possibly caused by higher doses and extended treatment duration in the individualized group. Antiviral therapy might have a more intense and more prolonged negative impact on females.
The radiative capture cross section of 238U is very important for the developing of new reactor technologies and the safety of existing ones. Here the preliminary results of the 238U(n,γ) cross section measurement performed at n_TOF with C6D6 scintillation detectors are presented, paying particular attention to data reduction and background subtraction.
73Ge(n, γ ) cross sections were measured at the neutron time-of-flight facility n_TOF at CERN up to neutron energies of 300 keV, providing for the first time experimental data above 8 keV. Results indicate that the stellar cross section at kT = 30 keV is 1.5 to 1.7 times higher than most theoretical predictions. The new cross sections result in a substantial decrease of 73Ge produced in stars, which would explain the low isotopic abundance of 73Ge in the solar system.
We have measured the radiative neutron-capture cross section and the total neutron-induced cross section of one of the most important isotopes for the s process, the 25Mg. The measurements have been carried out at the neutron time-of-flight facilities n_TOF at CERN (Switzerland) and GELINA installed at the EC-JRC-IRMM (Belgium). The cross sections as a function of neutron energy have been measured up to approximately 300 keV, covering the energy region of interest to the s process. The data analysis is ongoing and preliminary results show the potential relevance for the s process.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.