Refine
Year of publication
- 2003 (1)
Document Type
- Doctoral Thesis (1)
Language
- English (1)
Has Fulltext
- yes (1)
Is part of the Bibliography
- no (1)
Institute
The focus of this study were Celtic gold coins excavated from the Martberg, a Celtic oppidium and sanctuary, occupied in the first century B.C. by a Celtic tribe known as the Treveri. These coins and a number of associated coinages, were characterised in terms of their alloy compositions and their geochemical and isotopic signatures so as to answer archaeological and numismatic questions of coinage development and metal sources. This required the development of analytical methods involving; Electron Microprobe (EPMA), Laser Ablation-ICP-MS, solution Multicollector-ICPMS and LA-MC-ICP-MS. The alloy compositions (Au-Ag-Cu-Sn) were determined by EPMA on a small polished area on the edge of the coins. A large beam size, 50µm (diameter), was used to overcome the extreme heterogeneity of these alloys. These analyses were shown to be representative of the bulk composition of the coins. The metallurgical development of the coinages was defined and showed that the earlier coinages followed a debasement trend, which was superceded by a trend of increasing copper at the expense of sliver while gold compositions remained stable. This change occurred with the appearance of the inscribed "POTTINA" coinage, Scheers 30/V. Two typologically different coinages, Scheers 16 and 18 ("Armorican Types") were found to have markedly different compositions which do not fit into the trends described above. A Flan for a gold coin, which may indicate the presence of a mint at the Martberg, was found to have an identicle weight and composition as the Scheers 30/I coins, which preceeded the majority of the coins found at the Martberg in the coin development chronology. The trace element anaylses were made by Laser Ablation-ICPMS using an AridusTM desolvating nebuliser to introduce matrix matched solution standards to calibrate the measurements, which were then normalised to 100%. Quantitative results were obtained for the following elements: Sc, Ti, Cr, Mn, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Sb, Te, W, Ir, Pt, Pb, Bi. The remaining elements remain problematic as they produced incorrect standardisations mainly due to chemical effects in solution such as adsorption onto the beaker walls or oxidation : V, Fe, Ga, Ge, As, Mo, Sn, Re, Os, Hg. Changes in the sources of Au, Ag and Cu were observed during the development of the coinages through the variation of trace elements, which correlate positively with the major components of the coin alloys. Changes in the Pt/Au ratios show that the Scheers 23 coins contain distinctly different gold from the later coinages and that the Scheers 18 gold source was also different. Te/Ag was used to show that the Sch.23 coins also contained different silver and some subgroups were observed in the Sch. 30/V coins. A major change in copper source is indicated by the sudden increase of Sb and Ni with the introduction of the Sch. 30/V coins (POTTINA), which can be linked to a similar change in copper observed in the contemporary silver coinage, Sch. 55 (with a ring). Lead isotopic analyses were made by solution- and Laser Ablation - MC-ICP-MS, The laser technique proved to be in good agreement with the solution analyses with precisions between 1 and 0.1%o (per mil). The development of the laser method opens the way for easy and virtually non-destructive Pb isotopic determinations of ancient gold coins. The results showed that Sch. 23 is very different from the following coinages, Sch. 16 and 18 are also different, forming their own group, and all the later "Eye" staters (Sch. 30/I-VI) lie on a mixing line controlled by the addition of copper from a Mediterranean source, probably Sardinia or Spain. An indication of gold and silver sources should be possible with further analyses of the Sch. 23 and Rainbow Cup gold coins and the Sch. 54 and 55 silver coinages. Copper Isotopic analyses were made by solution- and Laser Ablation - MC-ICP-MS. Both techniques require further development to produce more reproducible results. The results show that there appears to be a trend to more positive d Cu65 values for the later coinages and that the link between the copper used in the Sch. 30/V (POTTINA) coins and the silver Sch. 55 (with a ring) coins is also shown by similarly postive d Cu65 values. The full suite of analyses were also made on samples of gold from the region. They were mostly composed of "placer gold", alluvial gold found in rivers. It was found that when a study is restricted to a limited number of deposits or areas then it is possible to distinguish between deposits based on the concentration of those elements which are least affected by transport related alteration processes. These elements include; the PGE's, due to their refractory nature, and those elements which are usually present in high enough concentrations to remain relatively unaffected, eg: Cu, Pb and Sb. Due to the nature of the coin alloy it is not possible to link the gold used in the coins studied here with gold deposits, as the large amounts of Ag and Cu, added to the coin alloys, have masked the Au signature. However, further Pb isotopic analyses of gold deposits should prove useful in determining from which regions Celtic gold was derived.