Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Objectives: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT.
The influence of biological maturity status (BMS) on talent identification and development within elite youth soccer is critically debated. During adolescence, maturity-related performance differences within the same age group may cause greater chances of being selected for early maturing players. Therefore, coaches need to consider players' BMS. While standard methods for assessing BMS in adolescents are expensive and time-consuming imaging techniques (i.e., X-ray and MRI), there also exist more pragmatic procedures. This study aimed to evaluate commonly used methods to assess BMS within a highly selected sample of youth soccer players. A total of N = 63 elite male soccer players (U12 and U14) within the German Soccer Association's talent promotion program completed a test battery assessing BMS outcomes. Utilizing MRI diagnostics, players' skeletal age (SAMRI) was determined by radiologists and served as the reference method. Further commonly used methods included skeletal age measured by an ultrasound device (SAUS), the maturity offset (MOMIR), and the percentage of adult height (PAHKR). The relation of these alternative BMS outcomes to SAMRI was examined using different perspectives: performing bivariate correlation analyses (1), modeling BMS as a latent variable (BMSlat) based on the multiple alternative diagnostics (2), and investigating individual differences in agreement (3). (1) Correlations of SAMRI and the further BMS variables ranked from r = 0.80 to r = 0.84 for the total sample and were lower for U12 (0.56 ≤ r ≤ 0.66), and U14 (0.61 ≤ r ≤ 0.74) (2). The latent structural equation modeling (SEM) (R2 = 51%) revealed a significant influence on BMSlat for MOMIR (β = 0.51, p <0.05). The additional contribution of PAHKR (β = 0.27, p = 0.06) and SAUS (β = −0.03, p = 0.90) was rather small (3). The investigation of individual differences between the reference method and alternative diagnostics indicated a significant bias for MOMIR (p <0.01). The results support the use of economical and time-efficient methods for assessing BMS within elite youth soccer. Bivariate correlation analyses as well as the multivariate latent variable approach highlight the measures' usefulness. However, the observed individual level differences for some of the utilized procedures led to the recommendation for practitioners to use at least two alternative assessment methods in order to receive more reliable information about players' BMS within the talent promotion process.
Background: Computed-tomography-guided interventions are attractive for tissue sampling of paediatric tumor lesions; however, it comes with exposure to ionizing radiation. The aim of this study was to analyse the radiation dose, accuracy and speed of CT-guided interventions in paediatric patient cohort.
Methods: We retrospectively reviewed CT-guided interventions over a 10 -year period in 65 children. The intervention site consisted of bones in 38, chest (lung) in 15 and abdomen (liver, lymph nodes) in 12 cases. Radiation dose and duration of the procedures were analysed. The statistical analysis was performed using dedicated statistical software (BiAS 8.3.6 software, Epsilon Verlag, North Hasted).
Results: All interventions were performed successfully. Mean target access path to lesion within the patients was 6.0 cm (min 3.5 cm, max 11.2 cm). Time duration to complete intervention was 25:15 min (min 17:03 min, max 43:00 min). The dose-length product (DLP) of intervention scan was 29.5 mGy · cm (min 6 mGy · cm, max 85 mGy · cm) with the lowest dose for biopsies in the region of the chest (p = 0.04).
Conclusions: With justified indications, CT-guided paediatric interventions are safe, effective and can be performed both, with short intervention times and low radiation exposure.
To analyze prospectively the interventional and clinical aspects of computed tomography-guided direct intratumoural injection of a novel chemotherapeutic administration and the parenchymal changes of tumour and necrosis in malignant liver tumours. Eight patients with 17 colorectal liver metastases were treated with a mean of 5.1 injections and nine patients with 13 hepatocellular carcinoma nodules with a mean of 3.1 treatments with computed tomography guided local applications of a novel cisplatin/epinephrine gel. This application provides a higher local and lower systemic drug concentration. Volumes of tumour and necrosis prior and after treatment were measured by computer generated volumetric analysis. Contrast enhanced studies verified pretherapeutic viable tumour volumes with a value of 77.4 ml in the metastases and 29.2 ml in the hepatocellular carcinoma nodules. Intratumoural drug application resulted in a significant increase of necrosis and a decrease in viable tumour volume to be 68.3 ml in metastases and 14.5 ml in hepatocellular carcinoma. Local therapy control rate for the follow up to 6 months was 38 and 71% for the group of metastases and hepatocellular carcinoma, respectively. Direct intratumoural injection of cisplatin/epinepthrine injectable gel is a feasible and good tolerated method and results in the development of a statistically significant increase in necrosis in malignant liver tumours. For hepatocellular carcinoma a higher local therapy control rate compared to colorectal metastases can be reported.
Objectives: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging.
Methods: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard.
Results: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05).
Conclusions: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations.
Key Points
• Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference.
• Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series.
• Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.
Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures.
Key Points: Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm 3 vs 80 mg/cm 3 ).
The objective of this pilot clinical study was to assess the safety, technical feasibility, pharmacokinetic (PK) profile and tumour response of DC Bead™ with irinotecan (DEBIRI™) delivered by intra-arterial embolisation for the treatment of metastatic colorectal cancer. Eleven patients with unresectable liver metastases from CRC, tumour burden <30% of liver volume, adequate haematological, liver and renal function, performance status of <2 were included in this study. Patients received up to 4 sessions of TACE with DEBIRI at 3-week intervals. Feasibility of the procedure, safety and tumour response were assessed after each cycle. PK was measured after the first cycle. Patients were followed up to 24 weeks. Only mild to moderate adverse events were observed. DEBIRI is a technically feasibile procedure; no technical complications were observed. Average Cmax for irinotecan and SN-38 was 194 ng/ml and 16.7 ng/ml, respectively, with average t½ of 4.6 h and 12.4 h following administration of DEBIRI. Best overall response during the study showed disease control in 9 patients (2 patients with partial response and 7 with stable disease, overall response rate of 18%). Our study shows that transarterial chemoembolisation with irinotecan-loaded DC beads (DEBIRI) is safe, technically feasible and effective with a good PK profile.
Introduction: We report on successful endovascular treatment of a hydrofluoric acid burn to the hand.
Report: A worker complained of severe pain in the fingers D II to D V after injury with 60% hydrofluoric acid. A digital subtraction angiography showed vasospasm of the common palmar digital artery. We selectively applied 20% calcium gluconate intra-arterially.
After treatment all arteries were perfused. Alprostadil, acetylsalicylic acid and clopidogrel were administered in conjunction. Pain symptoms improved and sensory and motor functions were restored.
Discussion: Immediate angiography and intra-arterial application of calcium gluconate are recommended to treat hydrofluoric acid burn to a limb.
Rationale and objectives: To provide a detailed analysis of injury patterns of the spine following blunt trauma and establish the role of supplementary MRI by evaluating discrepancies in the detection rates of damaged structures in CT and MRI.
Method: 216 patients with blunt trauma to the spine who underwent CT followed by supplementary MRI were included in this study. Two board-certified radiologists blinded to clinical symptoms and injury mechanisms independently interpreted all acquired CT and MRI images. The interpretation was performed using a dedicated catalogue of typical findings associated with spinal trauma and assessed for spinal stability using the AO classification systems.
Results: Lesions to structures associated with spinal instability were present in 31.0% in the cervical spine, 12.3% in the thoracic spine, and 29.9% in the lumbar spine. In all spinal segments, MRI provided additional information regarding potentially unstable injuries. Novel information derived from supplementary MRI changed clinical management in 3.6% of patients with injury to the cervical spine. No change in clinical management resulted from novel information on the thoracolumbar spine. Patients with injuries to the vertebral body, intervertebral disc, or spinous process were significantly more likely to benefit from supplementary MRI.