Refine
Year of publication
Document Type
- Article (15)
- Conference Proceeding (2)
- Preprint (2)
- Doctoral Thesis (1)
Has Fulltext
- yes (20)
Is part of the Bibliography
- no (20)
Keywords
Institute
- Physik (15)
- Medizin (4)
- Sportwissenschaften (2)
Time resolved measurements of the biased disk effect at an Electron Cyclotron Resonance Ion Source
(1999)
First results are reported from time resolved measurements of ion currents extracted from the Frankfurt 14 GHz Electron Cyclotron Resonance Ion Source with pulsed biased-disk voltage. It was found that the ion currents react promptly to changes of the bias. From the experimental results it is concluded that the biased disk effect is mainly due to improvements of the extraction conditions for the source and/or an enhanced transport of ions into the extraction area. By pulsing the disk voltage, short current pulses of highly charged ions can be generated with amplitudes significantly higher than the currents obtained in continuous mode.
In dieser Arbeit wird die Elektronenemission aus langsamen He 2 HeStößen, d.h. bei Stoßenergien unterhalb von 25 keV/u, experimentell untersucht. Dabei wird auf den Vergleich der Einfachionisation (He 2 He ! He 2 He e \Gamma ) mit der Transferionisation (He 2 He ! He He 2 e \Gamma ) besonderes Gewicht gelegt. Die hier verwendete Meßtechnik ist von verschiedenen Arbeitsgruppen in den letzten Jahren entwickelt worden und unter dem Schlagwort COLTRIMS (Cold Target Recoil Ion Momentum Spectroscopy) [1, 2, 3] in der Literatur zu finden. Bei COLTRIMS werden die bei einer Reaktion in einem kalten Gastarget gebildeten Ionen in einem schwachen elektrischen Feld abgesaugt. Durch den ortsaufgelösten Nachweis und die Messung der Flugzeit von der Targetzone bis zum Detektor kann die Anfangsbedingung der Bewegung im Feld, d.h. der Vektor des auf das Targetatom übertragenen Impulses, berechnet werden. Diese Methode kommt ohne Blenden aus, so daß im relevanten Teil des Phasenraumes 4ß Raumwinkel erreicht werden. Der Nachweis des Elektrons erfolgt nach demselben Prinzip, jedoch stößt man dabei an die Grenzen der Flugzeitauflösung. Deshalb wurden in allen früheren Experimenten zu ähnlichen Reaktionen [4, 5, 6, 7, 8, 9] nur zwei der drei Impulskomponenten des Elektrons bestimmt. Die Konzipierung eines Spektrometers, welches in der Lage ist, den relevanten Phasenraum lückenlos zu erfassen und dabei alle drei Impulskomponenten der Elektronen zu bestimmen, war der wesentliche Teil der apparativen Entwicklung. Das durchgeführte Experiment ist nicht nur kinematisch vollständig, sondern erlaubt durch Anwendung des Energieerhaltungssatzes auch die Bestimmung der Schale, in der das Elektron im Endzustand gebunden ist. Die beiden oben genannten Reaktionen können somit getrennt nach Ereignissen mit und ohne Anregung untersucht werden, d.h., es wurden gleichzeitig vier verschiedene Ionisationskanäle vermessen. Für den Ionisationsmechanismus bei Stößen mit einer Projektilgeschwindigkeit unterhalb der klassischen Bahngeschwindigkeit der Elektronen hat sich in den letzten Jahren der Begriff ''Sattelpunkt''Prozeß durchgesetzt [10]. Quantenmechanische Beschreibungen für Einelektronensysteme, wie das Stoßsystem p H, wurden u.a. mit der semiklassischen GekoppelteKanäleMethode [11] in einem speziellen Basissatz [12, 13] und der ''HiddenCrossings''Theorie [14, 15] gegeben. Beide Modelle beschreiben das System aus Projektil und Target als Quasimolekül. Si sind lediglich in der Lage, die groben Strukturen in den Spektren zu erklären. Das gewählte Stoßsystem He 2 He, welches zwei Elektronen besitzt, erlaubt die Untersuchung von Korrelationseffekten. Die Messungen haben ergeben, daß die Impulsverteilung des emittierten Elektrons stark davon abhängt, wo und in welchem Bindungszustand das zweite Elektron nachgewiesen wird. Die gleiche Kernladung von Projektil und Target bedingt, da alle Eigenzustände des gebildeten Quasimoleküls die Symmetrie des Hamiltonoperators gegenüber Raumspiegelung besitzen, und durch diese Spiegeloperation gehen die Endzustände der Transferionisation und der Einfachionisation ineinander über. Durch die gleichzeitige Messung der differentiellen Wirkungsquerschnitte der verschiedenen Reaktionskanäle und deren Vergleich erhält man Einblick in die zugrundeliegenden Prozesse.
Methodik
(2002)
Die vegetationskundliche und strukturelle Zuordnung der Lebensraumtypen erfolgt nach der vorrangig von Braun-Blanquet entwickelten Vegetationsklassifizierung, einer hierarchischen Gliederung der Vegetationstypen (Syntaxonomie), die die Ebenen der Assoziation, des Verbandes, der Ordnung und der Klasse umfasst. Hierbei ist die Assoziation die grundlegende Einheit, in der die Pflanzengesellschaften zusammengefasst werden, die sich durch gleiche charakteristische Arten(gruppen)kombinationen auszeichnen. Der Verband vereinigt ähnliche Assoziationen. Das sind bereits umfassendere, jedoch standörtlich noch recht einheitliche Vegetationseinheiten. In Ordnungen werden ähnliche Verbände zusammengefasst. Die Klasse vereinigt ähnliche Ordnungen.
We present the results of two-pion production in tagged quasi-free np collisions at a deutron incident beam energy of 1.25 GeV/c measured with the High-Acceptance Di-Electron Spectrometer (HADES) installed at GSI. The specific acceptance of HADES allowed for the first time to obtain high-precision data on π+π− and π−π0 production in np collisions in a region corresponding to large transverse momenta of the secondary particles. The obtained differential cross section data provide strong constraints on the production mechanisms and on the various baryon resonance contributions (∆∆, N(1440), N(1520), ∆(1600)). The invariant mass and angular distributions from the np → npπ+π −and np → ppπ−π0 reactions are compared with different theoretical model predictions.
n this paper we report on the investigation of baryonic resonance production in proton-proton collisions at the kinetic energies of 1.25 GeV and 3.5 GeV, based on data measured with HADES. Exclusive channels npπ+ and ppπ0 as well as ppe+e− were studied simultaneously in the framework of a one-boson exchange model. The resonance cross sections were determined from the one-pion channels for Δ(1232) and N(1440) (1.25 GeV) as well as further Δ and N* resonances up to 2 GeV/c2 for the 3.5 GeV data. The data at 1.25 GeV energy were also analysed within the framework of the partial wave analysis together with the set of several other measurements at lower energies. The obtained solutions provided the evolution of resonance production with the beam energy, showing a sizeable non-resonant contribution but with still dominating contribution of Δ(1232)P33. In the case of 3.5 GeV data, the study of the ppe+e− channel gave the insight on the Dalitz decays of the baryon resonances and, in particular, on the electromagnetic transition form-factors in the time-like region. We show that the assumption of a constant electromagnetic transition form-factors leads to underestimation of the yield in the dielectron invariant mass spectrum below the vector mesons pole. On the other hand, a comparison with various transport models shows the important role of intermediate ρ production, though with a large model dependency. The exclusive channels analysis done by the HADES collaboration provides new stringent restrictions on the parameterizations used in the models.
his contribution aims to give a basic overview of the latest results regarding the production of resonances in different collision systems. The results were extracted from experimental data collected with HADES that is a multipurpose detector located at the GSI Helmholtzzentrum, Darmstadt. The main points discussed here are: the properties of the strange resonances Λ(1405) and Σ(1385), the role of Δ’s as a source of pions in the final state, the production dynamics reflected in form of differential cross sections, and the role of the ϕ meson as a source for K− particles.
Purpose: The PELICAN trial evaluates for the first time efficacy and safety of pegylated liposomal doxorubicin (PLD) versus capecitabine as first-line treatment of metastatic breast cancer (MBC).
Methods: This randomized, phase III, open-label, multicenter trial enrolled first-line MBC patients who were ineligible for endocrine or trastuzumab therapy. Cumulative adjuvant anthracyclines of 360 mg/m2 doxorubicin or equivalent were allowed. Left ventricular ejection fraction of >50 % was required. Patients received PLD 50 mg/m2 every 28 days or capecitabine 1250 mg/m2 twice daily for 14 days every 21 days. The primary endpoint was time-to-disease progression (TTP).
Results: 210 patients were randomized (n = 105, PLD and n = 105, capecitabine). Adjuvant anthracyclines were given to 37 % (PLD) and 36 % (capecitabine) of patients. No significant difference was observed in TTP [HR = 1.21 (95 % confidence interval, 0.838–1.750)]. Median TTP was 6.0 months for both PLD and capecitabine. Comparing patients with or without prior anthracyclines, no significant difference in TTP was observed in the PLD arm (log-rank P = 0.64). For PLD versus capecitabine, respectively, overall survival (median, 23.3 months vs. 26.8 months) and time-to-treatment failure (median, 4.6 months vs. 3.7 months) were not statistically significantly different. Compared to PLD, patients on capecitabine experienced more serious adverse events (P = 0.015) and more cardiac events among patients who had prior anthracycline exposure (18 vs. 8 %; P = 0.31).
Conclusion: Both PLD and capecitabine are effective first-line agents for MBC.
The KER for electron capture of vibrational cooled HeH+ and H3 + ions at 20 keV from residual gas atoms has been measured in the Frankfurt Low Energy Storage Ring (FLSR). At a vacuum in the order of few 10-11 mbar, this residual gas consists to 99% of H2 molecules. For the identification of the recoil products of this reaction, a recoil spectrometer (with an MCP-detector with position and time sensitive read out) was installed at one of the focus points (IP) in the FLSR. The planned extension of this set up by a gas target to a full COLTRIMS reaction microscope will be discussed.