Refine
Keywords
- Fibrotest (1)
- HCV (1)
- HIV (1)
- Hepatotoxicity (1)
- Liver enzymes (1)
- Transient elastography (1)
- cART (1)
- co-infection (1)
Institute
-
Comparison of ELF, FibroTest and FibroScan for the non-invasive assessment of liver fibrosis
(2010)
- Background: FibroTest (FT) is the most frequently used serum fibrosis marker and consists of an algorithm of five fibrosis markers (alfa2-macroglobulin, apolipoproteinA1, haptoglobin, GGT, bilirubin). The Enhanced Liver Fibrosis (ELF) test consists of an algorithm of three fibrosis markers (hyaluronic acid, amino-terminal propeptide-of-type-III-collagen, tissue-inhibitor of matrix-metaloproteinase-1). While a systematic review has shown comparable results for both individual markers, there has been no direct comparison of both markers. Methods: In the present study, the ELF-test was analyzed retrospectively in patients with chronic liver disease, who received a liver biopsy, transient elastography (TE) and the FibroTest using histology as the reference method. Histology was classified according to METAVIR and the Ludwig's classification (F0-F4) for patients with chronic hepatitis C and B virus (HCV, HBV) infection and primary biliary cirrhosis (PBC), respectively. Results: Seventy-four patients were analysed: 36 with HCV, 10 with HBV, and 28 with PBC. The accuracy (AUROC) for the diagnosis of significant fibrosis (F[greater than or equal to]2) for ELF and FibroTest was 0.78 (95%CI:0.67-0.89) and 0.69 (95%-CI:0.57-0.82), respectively (difference not statistically significant, n.s.). The AUROC for the diagnosis of liver cirrhosis was 0.92 (95%CI:0.83-1,00), and 0.91 (95%CI:0.83-0.99), respectively (n.s.). For 66 patients with reliable TE measurements the AUROC for the diagnosis of significant fibrosis (cirrhosis) for TE, ELF and FT were 0.80 (0.94), 0.76 (0.92), and 0.67 (0.91), respectively (n.s.). Conclusion: FibroTest and ELF can be performed with comparable diagnostic accuracy for the non-invasive staging of liver fibrosis. Serum tests are informative in a higher proportion of patients than transient elastography.
-
Serum microRNA-21 as marker for necroinflammation in hepatitis C patients with and without hepatocellular carcinoma
(2011)
- Background: MicroRNA-21 (miR-21) is up-regulated in tumor tissue of patients with malignant diseases, including hepatocellular carcinoma (HCC). Elevated concentrations of miR-21 have also been found in sera or plasma from patients with malignancies, rendering it an interesting candidate as serum/plasma marker for malignancies. Here we correlated serum miR-21 levels with clinical parameters in patients with different stages of chronic hepatitis C virus infection (CHC) and CHC-associated HCC. Methodology/Principal Findings: 62 CHC patients, 29 patients with CHC and HCC and 19 healthy controls were prospectively enrolled. RNA was extracted from the sera and miR-21 as well as miR-16 levels were analyzed by quantitative real-time PCR; miR-21 levels (normalized by miR-16) were correlated with standard liver parameters, histological grading and staging of CHC. The data show that serum levels of miR-21 were elevated in patients with CHC compared to healthy controls (P<0.001); there was no difference between serum miR-21 in patients with CHC and CHC-associated HCC. Serum miR-21 levels correlated with histological activity index (HAI) in the liver (r = −0.494, P = 0.00002), alanine aminotransferase (ALT) (r = −0.309, P = 0.007), aspartate aminotransferase (r = −0.495, P = 0.000007), bilirubin (r = −0.362, P = 0.002), international normalized ratio (r = −0.338, P = 0.034) and γ-glutamyltransferase (r = −0.244, P = 0.034). Multivariate analysis revealed that ALT and miR-21 serum levels were independently associated with HAI. At a cut-off dCT of 1.96, miR-21 discriminated between minimal and mild-severe necroinflammation (AUC = 0.758) with a sensitivity of 53.3% and a specificity of 95.2%. Conclusions/Significance: The serum miR-21 level is a marker for necroinflammatory activity, but does not differ between patients with HCV and HCV-induced HCC.
-
Acoustic radiation force impulse imaging for differentiation of thyroid nodules
(2012)
- Background: Acoustic Radiation Force Impulse (ARFI)-Imaging is an ultrasound-based elastography method enabling quantitative measurement of tissue stiffness. The aim of the present study was to evaluate sensitivity and specificity of ARFIimaging for differentiation of thyroid nodules and to compare it to the well evaluated qualitative real-time elastography (RTE). Methods: ARFI-imaging involves the mechanical excitation of tissue using acoustic pulses to generate localized displacements resulting in shear-wave propagation which is tracked using correlation-based methods and recorded in m/s. Inclusion criteria were: nodules $5 mm, and cytological/histological assessment. All patients received conventional ultrasound, real-time elastography (RTE) and ARFI-imaging. Results: One-hundred-fifty-eight nodules in 138 patients were available for analysis. One-hundred-thirty-seven nodules were benign on cytology/histology, and twenty-one nodules were malignant. The median velocity of ARFI-imaging in the healthy thyroid tissue, as well as in benign and malignant thyroid nodules was 1.76 m/s, 1.90 m/s, and 2.69 m/s, respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.0019) or benign thyroid nodules (p = 0.0039) on the other hand. No significant difference of diagnostic accuracy for the diagnosis of malignant thyroid nodules was found between RTE and ARFI-imaging (0.74 vs. 0.69, p = 0.54). The combination of RTE with ARFI did not improve diagnostic accuracy. Conclusions: ARFI can be used as an additional tool in the diagnostic work up of thyroid nodules with high negative predictive value and comparable results to RTE.
-
Assessment of liver fibrosis and associated risk factors in HIV-infected individuals using transient elastography and serum biomarkers
(2012)
- Background: Liver fibrosis in human immunodeficiency virus (HIV)-infected individuals is mostly attributable to co-infection with hepatitis B or C. The impact of other risk factors, including prolonged exposure to combined antiretroviral therapy (cART) is poorly understood. Our aim was to determine the prevalence of liver fibrosis and associated risk factors in HIV-infected individuals based on non-invasive fibrosis assessment using transient elastography (TE) and serum biomarkers (Fibrotest [FT]). Methods: In 202 consecutive HIV-infected individuals (159 men; mean age 47 ± 9 years; 35 with hepatitis-C-virus [HCV] co-infection), TE and FT were performed. Repeat TE examinations were conducted 1 and 2 years after study inclusion. Results: Significant liver fibrosis was present in 16% and 29% of patients, respectively, when assessed by TE (≥ 7.1 kPa) and FT (> 0.48). A combination of TE and FT predicted significant fibrosis in 8% of all patients (31% in HIV/HCV co-infected and 3% in HIV mono-infected individuals). Chronic ALT, AST and γ-GT elevation was present in 29%, 20% and 51% of all cART-exposed patients and in 19%, 8% and 45.5% of HIV mono-infected individuals. Overall, factors independently associated with significant fibrosis as assessed by TE (OR, 95% CI) were co-infection with HCV (7.29, 1.95-27.34), chronic AST (6.58, 1.30-33.25) and γ-GT (5.17, 1.56-17.08) elevation and time on dideoxynucleoside therapy (1.01, 1.00-1.02). In 68 HIV mono-infected individuals who had repeat TE examinations, TE values did not differ significantly during a median follow-up time of 24 months (median intra-patient changes at last TE examination relative to baseline: -0.2 kPa, p = 0.20). Conclusions: Chronic elevation of liver enzymes was observed in up to 45.5% of HIV mono-infected patients on cART. However, only a small subset had significant fibrosis as predicted by TE and FT. There was no evidence for fibrosis progression during follow-up TE examinations.