Refine
Year of publication
Document Type
- Article (29)
- Preprint (2)
- Conference Proceeding (1)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- 140Ce (1)
- Electromagnetic transitions (1)
- Human behaviour (1)
- MACS (1)
- Models & methods for nuclear reactions (1)
- Neutron physics (1)
- Nuclear reactions (1)
- Psychiatric disorders (1)
- Radiative capture (1)
- Resonance reactions (1)
Institute
- Physik (28)
- Medizin (2)
- Biochemie, Chemie und Pharmazie (1)
- Extern (1)
Feasibility, design and sensitivity studies on innovative nuclear reactors that could address the issue of nuclear waste transmutation using fuels enriched in minor actinides, require high accuracy cross section data for a variety of neutron-induced reactions from thermal energies to several tens of MeV. The isotope 241Am (T1/2= 433 years) is present in high-level nuclear waste (HLW), representing about 1.8 % of the actinide mass in spent PWR UOx fuel. Its importance increases with cooling time due to additional production from the β-decay of 241Pu with a half-life of 14.3 years. The production rate of 241 Am in conventional reactors, including its further accumulation through the decay of 241Pu and its destruction through transmutation/incineration are very important parameters for the design of any recycling solution. In the present work, the 241 Am(n,f) reaction cross-section was measured using Micromegas detectors at the Experimental Area 2 of the n_TOF facility at CERN. For the measurement, the 235U(n,f) and 238U(n,f) reference reactions were used for the determination of the neutron flux. In the present work an overview of the experimental setup and the adopted data analysis techniques is given along with preliminary results.
Romane in Zeitungen
(1900)
An accurate measurement of the 140Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140Ce Maxwellian-averaged cross-section.
Previous research indicates that anxiety disorders are characterized by an overgeneralization of conditioned fear as compared with healthy participants. Therefore, fear generalization is considered a key mechanism for the development of anxiety disorders. However, systematic investigations on the variance in fear generalization are lacking. Therefore, the current study aims at identifying distinctive phenotypes of fear generalization among healthy participants. To this end, 1175 participants completed a differential fear conditioning phase followed by a generalization test. To identify patterns of fear generalization, we used a k-means clustering algorithm based on individual arousal generalization gradients. Subsequently, we examined the reliability and validity of the clusters and phenotypical differences between subgroups on the basis of psychometric data and markers of fear expression. Cluster analysis reliably revealed five clusters that systematically differed in mean responses, differentiation between conditioned threat and safety, and linearity of the generalization gradients, though mean response levels accounted for most variance. Remarkably, the patterns of mean responses were already evident during fear acquisition and corresponded most closely to psychometric measures of anxiety traits. The identified clusters reliably described subgroups of healthy individuals with distinct response characteristics in a fear generalization test. Following a dimensional view of psychopathology, these clusters likely delineate risk factors for anxiety disorders. As crucial group characteristics were already evident during fear acquisition, our results emphasize the importance of average fear responses and differentiation between conditioned threat and safety as risk factors for anxiety disorders.
Evidence gained from recent studies has generated increasing interest in the role of vitamin D in extraskeletal functions such as inflammation and immunoregulation. Although vitamin D deficiency has been implicated in the pathophysiology of inflammatory diseases including inflammatory bowel disease (IBD), evidence as to whether vitamin D supplementation may cure or prevent chronic disease is inconsistent. Since 25OH-vitamin D (25OHD) has been suggested to be an acute-phase protein, its utility as a vitamin D status marker is therefore questionable. In this study, possible interactions of vitamin D and inflammation were studied in 188 patients with IBD, with high-sensitivity C-reactive protein (hsCRP) levels ≥ 5 mg/dL and/or fecal calprotectin ≥ 250 µg/g defined as biochemical evidence of inflammatory activity. Levels of 25OHD and vitamin D-binding protein (VDBP) were determined by ELISA, and 1,25-dihydroxyvitamin D (1,25OHD) and dihydroxycholecalciferol (24,25OHD) by LC-MS/MS. Free and bioavailable vitamin D levels were calculated with the validated formula of Bikle. Serum 1,25OH2D and vitamin D binding protein (VDBP) levels were shown to differ between the inflammatory and noninflammatory groups: patients with inflammatory disease activity had significantly higher serum concentrations of 1,25OH2D (35.0 (16.4–67.3) vs. 18.5 (1.2–51.0) pg/mL, p < 0.001) and VDBP (351.2 (252.2–530.6) vs. 330.8 (183.5–560.3) mg/dL, p < 0.05) than patients without active inflammation. Serum 24,25OH2D levels were negatively correlated with erythrocyte sedimentation rate (ESR) (−0.155, p = 0.049) while concentrations of serum 1,25OH2D correlated positively with hsCRP (0.157, p = 0.036). Correlations with serum VDBP levels were found for ESR (0.150, p = 0.049), transferrin (0.160, p = 0.037) and hsCRP (0.261, p < 0.001). Levels of serum free and bioavailable 25OHD showed a negative correlation with ESR (−0.165, p = 0.031, −0.205, p < 0.001, respectively) and hsCRP (−0.164, p = 0.032, −0.208, p < 0.001 respectively), and a moderate negative correlation with fecal calprotectin (−0.377, p = 0.028, −0.409, p < 0.016, respectively). Serum total 25OHD concentration was the only vitamin D parameter found to have no specific correlation with any of the inflammatory markers. According to these results, the traditional parameter, total 25OHD, still appears to be the best marker of vitamin D status in patients with inflammatory bowel disease regardless of the presence of inflammation.
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n_TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of kT = 5 – 100 keV, and their astrophysical implications were investigated.
Since the start of its operation in 2001, based on an idea of Prof. Carlo Rubbia [1], the neutron time of-flight facility of CERN, n_TOF, has become one of the most forefront neutron facilities in the world for wide-energy spectrum neutron cross section measurements. Thanks to the combination of excellent neutron energy resolution and high instantaneous neutron flux available in the two experimental areas, the second of which has been constructed in 2014, n_TOF is providing a wealth of new data on neutron-induced reactions of interest for nuclear astrophysics, advanced nuclear technologies and medical applications. The unique features of the facility will continue to be exploited in the future, to perform challenging new measurements addressing the still open issues and long-standing quests in the field of neutron physics. In this document the main characteristics of the n_TOF facility and their relevance for neutron studies in the different areas of research will be outlined, addressing the possible future contribution of n_TOF in the fields of nuclear astrophysics, nuclear technologies and medical applications. In addition, the future perspectives of the facility will be described including the upgrade of the spallation target, the setup of an imaging installation and the construction of a new irradiation area.
Setup for the measurement of the 235U(n,f) cross section relative to n-p scattering up to 1 GeV
(2020)
The neutron induced fission of 235U is extensively used as a reference for neutron fluence measurements in various applications, ranging from the investigation of the biological effectiveness of high energy neutrons, to the measurement of high energy neutron cross sections of relevance for accelerator driven nuclear systems. Despite its widespread use, no data exist on neutron induced fission of 235U above 200 MeV. The neutron facility n_TOF offers the possibility to improve the situation. The measurement of 235U(n,f) relative to the differential n-p scattering cross-section, was carried out in September 2018 with the aim of providing accurate and precise cross section data in the energy range from 10 MeV up to 1 GeV. In such measurements, Recoil Proton Telescopes (RPTs) are used to measure the neutron flux while the fission events are detected and counted with dedicated detectors. In this paper the measurement campaign and the experimental set-up are illustrated.