Refine
Year of publication
Has Fulltext
- yes (20)
Is part of the Bibliography
- no (20)
Keywords
- SARS-CoV-2 (4)
- COVID-19 (3)
- mandatory reporting (2)
- Air traffic (1)
- Antigen test (1)
- Arbeitsbedingt erworbene Infektion (1)
- B.1.1.7 (1)
- B.1.617.1 (1)
- B.1.617.2 (1)
- BNT2b2 (1)
Institute
- Medizin (17)
- Frankfurt Institute for Advanced Studies (FIAS) (3)
- Informatik (3)
- Physik (3)
Hintergrund: Eine standardisierte Erhebung von COVID-19-Infektionen bei Gesundheitspersonal während der laufenden Pandemie war und ist nicht gegeben. Vor allem der Anteil von arbeitsbedingten Infektionen beim Gesundheitspersonal und die Frage, welche Arbeitnehmer/-innen darunter am meisten gefährdet sind, bleiben unklar.
Ziel: Ziel dieser Studie war es, die gemeldeten COVID-19-Fälle beim Gesundheitspersonal in Frankfurt/Main in den ersten 6 Monaten der Pandemie zu analysieren, die Zahl der arbeitsbedingten Infektionen zu ermitteln und somit eine bessere Interpretation der durch das Robert Koch-Institut veröffentlichten Daten zu ermöglichen.
Methoden: Die Daten des Gesundheitsamts Frankfurt/Main wurden für den Zeitraum vom 01.03. bis zum 31.08.2020 betrachtet und medizinisches Personal für eine Querschnittserhebung im Rahmen einer Umfrage rekrutiert. Drei Subgruppen wurden nach Ort des Infektionskontakts, am Arbeitsplatz, im Privaten und unbekannt, unterteilt und analysiert.
Ergebnisse: Medizinisches Personal machte 11,8 % (319/2700) aller gemeldeten COVID-19-Fälle in Frankfurt/Main im untersuchten Zeitraum aus. In der Umfrage gaben 47,2 % der Befragten an, dass ihre Infektion am Arbeitsplatz erworben wurde. Es zeigte sich eine Assoziation von Kontakt zu COVID-19-Patient/-innen sowie der Beschäftigung auf einer internistischen Station und einer arbeitsbedingten Infektion. Ersichtlich wurde außerdem ein Zusammenhang zwischen mutmaßlichen Infektionen am Arbeitsplatz und folglich gestellten Verdachtsanzeigen auf Berufskrankheit.
Diskussion und Fazit: Gesundheitsämter sind in der Lage, relevante Daten von arbeitsbedingten Transmissionen in Berufen und Arbeitsplätzen im Gesundheitswesen zu erheben, und sollten standardisierte Daten zu infiziertem Gesundheitspersonal generieren. Diese Daten sind notwendig, um gezielte Maßnahmen der Infektionsprävention zu ergreifen, die Gesundheitspersonal und ihre Patient/-innen schützen.
Background: International travel poses the risk of importing SARS-CoV-2 infections and introducing new viral variants into the country of destination. Established measures include mandatory quarantine with the opportunity to abbreviate it with a negative rapid antigen test (RAT).
Methods: A total of 1,488 returnees were tested for SARS-CoV-2 with both PCR and RAT no earlier than 5 days after arrival. We assessed the sensitivity and specificity of the RAT. Positive samples were evaluated for infectivity in vitro in a cell culture outgrowth assay. We tracked if participants who tested negative were reported positive within 2 weeks of the initial test.
Results: Potential infectiousness was determined based on symptom onset analysis, resulting in a sensitivity of the antigen test of 89% in terms of infectivity. The specificity was 100%. All positive outgrowth assays were preceded by a positive RAT, indicating that all participants with proven in vitro infectivity were correctly identified. None of the negative participants tested positive during the follow-up.
Conclusions: RAT no earlier than the 5th day after arrival was a reliable method for detecting infectious travellers and can be recommended as an appropriate method for managing SARS-CoV-2 travel restrictions. Compliance to the regulations and a high standard of test quality must be ensured.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections. We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R. We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 8.00 and 5.33, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.51-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab. In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which, however, might be circumvented by combination therapy with casirivimab together.
Background: International travel is a major driver of the introduction and spread of SARS- CoV-2. Aim: To investigate SARS-CoV-2 genetic diversity in the region of a major transport hub in Germany, we characterized the viral sequence diversity of the SARS-CoV-2 variants circulating in Frankfurt am Main, the city with the largest airport in Germany, from the end of October to the end of December 2020. Methods: In total, we recovered 136 SARS-CoV-2 genomes from nasopharyngeal swab samples. We isolated 104 isolates that were grown in cell culture and RNA from the recovered viruses and subjected them to full-genome sequence analysis. In addition, 32 nasopharyngeal swab samples were directly sequenced. Results and conclusion: We found 28 different lineages of SARS- CoV-2 circulating during the study period, including the variant of concern B.1.1.7 (∆69/70, N501Y). Six of the lineages had not previously been observed in Germany. We detected the spike protein (S) deletion ∆69/∆70 in 15% of all sequences, a four base pair (bp) deletion (in 2.9% of sequences) and a single bp deletion (in 0.7% of sequences) in ORF3a, leading to ORF3a truncations. In four sequences (2.9%), an amino acid deletion at position 210 in S was identified. In a single sample (0.7%), both a 9 bp deletion in ORF1ab and a 7 bp deletion in ORF7a were identified. One sequence in lineage B.1.1.70 had an N501Y substitution while lacking the ∆69/70 in S. The high diversity of sequences observed over two months in Frankfurt am Main highlights the persisting need for continuous SARS-CoV-2 surveillance using full-genome sequencing, particularly in cities with international airport connections.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections.
We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R.
We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 5.71 and 3.64, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.6-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab.
In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which however, might be circumvented by a combination therapy with casirivimab together.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections.
We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R.
We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 8.00 and 5.33, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.5-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab.
In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which however, might be circumvented by a combination therapy with casirivimab together.
Testing for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by RT-PCR is a vital public health tool in the pandemic. Self-collected samples are increasingly used as an alternative to nasopharyngeal swabs. Several studies suggested that they are sufficiently sensitive to be a useful alternative. However, there are limited data directly comparing several different types of self-collected materials to determine which material is preferable. A total of 102 predominantly symptomatic adults with a confirmed SARS-CoV-2 infection self-collected native saliva, a tongue swab, a mid-turbinate nasal swab, saliva obtained by chewing a cotton pad and gargle lavage, within 48 h of initial diagnosis. Sample collection was unsupervised. Both native saliva and gargling with tap water had high diagnostic sensitivity of 92.8% and 89.1%, respectively. Nasal swabs had a sensitivity of 85.1%, which was not significantly inferior to saliva (p = 0.092), but 16.6% of participants reported they had difficult in self-collection of this sample. A tongue swab and saliva obtained by chewing a cotton pad had a significantly lower sensitivity of 74.2% and 70.2%, respectively. Diagnostic sensitivity was not related to the presence of clinical symptoms or to age. When comparing self-collected specimens from different material, saliva, gargle lavage or mid-turbinate nasal swabs may be considered for most symptomatic patients. However, complementary experiments are required to verify that differences in performance observed among the five sampling modes were not attributed to collection impairment.
Introduction: From the beginning of the corona pandemic until August 19, 2020, more than 21,989,366 cases have been reported worldwide – 228,495 in Germany alone, including 12,648 children aged 0–14. In many countries, the proportion of infected children in the total population is comparatively low; in addition, children often have no or milder symptoms and are less likely to transmit the pathogen to adults than the other way round. Based on the registration data in Frankfurt am Main, Germany, the symptoms of children in comparison with adults and the likely routes of transmission are presented below.
Materials and methods: The documentation of the mandatory reports includes personal data (name, date of birth, gender, place of residence), disease characteristics (date of report, date of onset of the disease, symptoms), possible contact persons (family, others) and i.a. possible activity or care in children’s community facilities. All reports were viewed, especially with regard to likely transmission routes.
Results: From March 1 to July 31, 2020, 1,977 infected people were reported, including 138 children between the ages of 0 and 14 years. Children had fewer and milder symptoms than adults. None of the children experienced severe respiratory symptoms or the need for ventilation. 62% of the children had no symptoms at all (19% adults), 5% of the children were hospitalized (24% adults), and none of the children died (3.8% adults).
After excluding a cluster of 34 children from refugee accommodations and 14 children from a parish, 78% of the remaining 90 children had been infected by an adult within the family, and only 4% were likely to have a reverse transmission route. In 5.5% of cases, transmission in a community facility was likely.
Discussion: The results of the registration data from Frankfurt am Main, Germany confirm the results published in other countries: Children are less likely to become infected, and if infected, their symptoms are less severe than in adults, and they are apparently not the main drivers of virus transmission. Therefore, scientific medical associations strongly recommend reopening schools.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.