Refine
Document Type
- Doctoral Thesis (6)
- Master's Thesis (1)
Has Fulltext
- yes (7)
Is part of the Bibliography
- no (7)
Keywords
- ALICE <Teilchendetektor> (1)
- ALICE <particle detector> (1)
- Ageing (1)
- CBM Experiment (1)
- CERN (1)
- Control System (1)
- Dissertation (1)
- EPICS (1)
- Hochenergiephysik (1)
- Kalibrieren <Messtechnik> (1)
Institute
- Physik (4)
- Biochemie und Chemie (2)
- Medizin (1)
ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.
Die vorliegende Promotionsarbeit fokussiert auf das transfusionsbedingte Infektionsrisiko bezüglich Hepatitis B-Virus Infektionen. Da das Restinfektionsrisiko bezüglich Hepatitis B deutlich höher als das Restinfektionsrisiko bezüglich Hepatitis C oder HIV-Virus Infektionen anzusehen ist, konzentriert sich die vorliegende Arbeit auf den Stellenwert von Anti-HBc Antikörper für das Blutspenderscreening. In der vorliegenden Arbeit wurden zunächst unterschiedliche Anti-HBs Screening Assays synoptisch bezüglich der Sensitivität und Spezifität sowie anderer Test-Parameter miteinander verglichen und die Prävalenz und Infektiosität Anti-HBc-Ak positiver Blutspenden des Blutspendedienstes Hessen / Baden-Württemberg untersucht. Anschließend erfolgte eine Screening an fünf unterschiedlichen Standorten in Deutschland zur Prävalenz von Anti-HBc sowie zum Prozentsatz von chronisch infizierten Hepatitis B positiven Spendern. Anhand von Lookback Untersuchungen von chronisch infizierten Anti-HBc positiven und HBV DNA positiven Spendern konnte untersucht werden, inwieweit die Transfusion dieser niedrig virämischen Spender zu einer Übertragung von Hepatitis B in der Vergangenheit geführt hat. Darüber hinaus wurde eine Fall-Kontroll-Studie durchgeführt, mit der Fragestellung, inwieweit allein das Vorhandensein von Hepatitis B Antikörper (Anti-HBc Antikörper und Anti-HBe Antikörper) ohne Nachweis von HBV DNA, bereits ein erhöhtes Transfusionsrisiko darstellt. Zusätzlich wurden Daten bezüglich der heutigen Relevanz der HBs-Ag Testung im Blutspendewesen erhoben. Anschließend wurden alle drei für die Doktorarbeit relevanten Screeningparameter bezüglich Hepatitis B für das Blutspenderscreening (HBV Minipool PCR, HBs-Ag Test und Anti-HBc Test) bezüglich der Kosten pro gewonnenen QALY (Quality Adjusted Life Years) berechnet und wieder synoptisch miteinander verglichen. In der abschließenden Diskussion wurden unterschiedliche Screening Szenarien auf ihre Wertigkeit bezüglich der Sicherheit der Blutprodukte sowie auf ihre Kosten-Nutzen-Analyse hin betrachtet. Festgestellt wurde, dass durch die Anti-HBc-Ak Diagnostik im Blutspendewesen eine erhöhte Sicherheit bezüglich einer transfusionsbedingten HBV Transmission erzielt werden kann. Unter ca. 1,4 Millionen untersuchten Spendern konnten 21 HBV DNA positive Spender (alle niedrige HBV DNA Konzentrationen) ermittelt werden. Bei keinem der jeweiligen Empfänger konnte eine Infektion bestätigt werden, bei einem wäre sie möglich gewesen. Dabei konnte gezeigt werden, dass sich das PRISM® HBcore™ Testsystem wegen guter Sensitivität aber auch gleichzeitig guter Spezifität (signifikant besser als PRISM® HBc™) am besten zur Anti-HBc-Ak Routinetestung im Blutspendedienst eignet und selbst bei sehr hohem Probenaufkommen bewährt hat. Im Vergleich unterschiedlicher Testsysteme hatte der AxSym® CORE™ die höchste analytische Sensitivität, im weiteren Vergleich schnitten die untersuchten Assays annähernd gleich ab, zwischen dem PRISM® HBcore™ und PRISM® HBc™ konnte kein weiterer signifikanter Unterschied festgestellt werden. Des weiteren konnte gezeigt werden, dass Anti-HBc-Ak einen guten und sinnvollen Parameter zur HBV Diagnostik darstellt, der, in Verbindung mit der Pool-PCR, eventuell sogar die HBs-Ag Testung abzulösen in der Lage ist. Anhand der im Rahmen dieser Studie erhobenen Daten wären alle HBs-Ag positiven Blutprodukte auch mittels der Pool-PCR und Anti-HBc-Ak Diagnostik identifiziert worden. Darüber hinaus wurden einige HBV positive Blutprodukte mit diesen Verfahren erkannt, die mittels der klassischen HBs-Ag Testung übersehen worden wären. Bestätigt Anti-HBc-Ak positive Spender lassen sich anhand zusätzlicher serologischer Parameter (Anti-HBe-Ak und Anti-HBs-Ak) und wiederholter Testung bestimmen und so auch bestätigen; Die gemessenen S/CO-Werte der einzelnen untersuchten Testsysteme sind in der Lage einen Hinweis auf eine mögliche unspezifische Anti-HBc-Ak Reaktivität geben, so dass in Verbindung mit zusätzlichen HBV Parametern (z.B. Anti-HBe-Ak), die Richtigkeit des Ergebnisses besser eingeschätzt werden kann. Mittels Testung auf weitere HBV Marker (Einzelproben-PCR, Anti-HBs-Ak) können, wie es bereits gesetzlich geregelt wurde, Anti-HBc-Ak positive Blutprodukte durch ein „Re-Entry“ Verfahren wieder der Patientenverwendung zugeführt werden, ohne das HBV Transmissionsrisiko zu erhöhen. Die vorliegende Studie bestätigt diese Annnahme: Es konnte keine einzige HBV Transmission durch Anti-HBc-Ak positives Blut bewiesen werden, welches HBV PCR negativ (Sens. < 5,6 IU/ml) war. Die Prävalenz der Anti-HBc-Ak positiven Blutspender betrug vor Einführung der Anti-HBc-Ak Testung ca. 1,61%, im Spenderkollektiv wird sie aber wegen Selektionierung in den nächsten Jahren stark rückläufig sein.
The ALICE Time Projection Chamber (TPC) is the main tracking detector of ALICE which was designed to perform well at multiplicities of up to 20000 charged primary and secondary tracks emerging from Pb-Pb collisions. Successful operation of such a large and complex detector requires an elaborate calibration and commissioning. The main goal for the calibration procedures is to provide the information needed for the offline software for the reconstruction of the particle tracks with sufficient precision so that the design performance can be achieved. For a precise reconstruction of particle tracks in the TPC, the calibration of the drift velocity, which in conjunction with the drift time provides the z position of the traversing particles, is essential. In this thesis, an online method for the calibration of the drift velocity is presented. It uses the TPC Laser System which generates 336 straight tracks within the active volume of the TPC. A subset of these tracks, showing sufficiently small distortions, is used in the analysis. The resulting time dependent drift velocity correction parameters are entered into a database and provide start values for the offline reconstruction chain of ALICE. Even though no particle tracking information is used, the online drift velocity calibration is in agreement with the full offline calibration including tracking on the level of about 2 x 10 exp (-4). In chapter 2, a short overview of the ALICE detector, as well as the data taking model of the ALICE, is given. In chapter 3, the TPC detector is described in detail. Lastly in chapter 4, the online drift velocity calibration method is presented, together with a detailed description of the TPC laser system.
Construction and commissioning of a setup to study ageing phenomena in high rate gas detectors
(2014)
In high-rate heavy-ion experiments, gaseous detectors encounter big challenges in terms of degradation of their performance due to a phenomenon dubbed ageing. In this thesis, a setup for high precision ageing studies has been constructed and commissioned at the GSI detector laboratory. The main objective is the study of ageing phenomena evoked by materials used to build gaseous detectors for the Compressed Baryonic Matter (CBM) experiment at the future Facility for Antiproton and Ion Research (FAIR).
The precision of the measurement, e.g., of the gain of a gaseous detector, is a key element in ageing studies: it allows to perform the measurement at realistic rates in an acceptable time span. It is well known the accelerating ageing employing high intensity sources might produce misleading results. The primary objective is to build an apparatus which allows very accurate measurements and is thus sensitive to minute degradations in detector performance. The construction and commissioning of the
setup has been carried out in two steps. During the first step of this work, a simpler setup which already existed in the detector laboratory of GSI had been utilised to define all conditions related to ageing studies. The outcome of these studies defined the properties and characteristics that must be met to build and operate a new, sophisticated and precise setup. The already existing setup consisted of two identical Multi Wire Proportional Chambers (MWPCs), a gas mixing station, an 55Fe source, an x-ray generator, an outgassing box and stainless steel tubing. In a first step, the gain and electric field configuration of the MWPCs were simulated by a combination of a gas simulation (Magboltz) and electric field simulation program (Garfield). The performance and operating conditions of the chambers have been thoroughly characterised before utilising them in first preparatory ageing test. The main diagnostic parameter in ageing studies is the detector gain, thus it is mandatory for precise ageing studies to minimise the systematic and statistical variation of the pressure and temperature corrected gain. To achieve the required accuracy, several improvements of the chamber design and the gas system have been implemented. In addition, the temperature measurement has been optimised. During the preparatory tests, several ageing studies have been carried out. The ageing effect of seven materials and gases have been carried out during these tests: RTV-3145, Ar/CO2 gas, Durostone flushed with Ar/Isobutane gas, Vetronit G11, Vetronit G11 contaminated with Micro 3000 and Gerband 705. The results of these studies went into the design of the new sophisticated ageing setup. For example some tests revealed that there was, even after cleaning, a certain level of contamination with "ageing agents" in the existing setup, which made it imperative to ensure a very high level cleanness of all components during the construction of the setup. The curing period of some testing samples like glues or the gas flow rate were found to be very important factors that must be taken into account to obtain comparable results. Very important changes in the chamber design have been made, i.e., the aluminium-Kapton cathodes used in MWPCs have been replaced with multi-wire planes and the fibreglass housing of the chamber has been changed to metal. The second step started with building the new setup which was designed based on the findings from the first step. The new ageing setup consists of three MWPCs, two moving platforms, an 55Fe source, a copper-anode x-ray generator, two outgassing boxes, both flexible and rigid stainless steel tubes. Before fabrication of the chambers, simulations of their electric field and the gain have been done using Magboltz and Garfield programs. After that, the chambers were installed and tested. A 0.3% peak-to-peak residual variation of the corrected gain has been achieved. Finally, the complete setup has been operated with full functionality in no-ageing conditions during one week. This test revealed very stable gain in all three chambers. After that two materials (Gerban 705 and RTV-3145) have been inserted in the two outgassing boxes and tested. They revealed an ageing rate of about 0.3%/mC/cm and 3%/mC/cm respectively. The final test proves the stability and accuracy of the ageing measurements carried out with the ageing setup at the detector laboratory at GSI which is ready to conduct the envisaged systematic ageing studies.
Mit Hilfe der direkten Nachweismethode von Singulettsauerstoff über die 1O2-Phosphoreszenzemission bei 1270 nm wurden zeitabhängige Messungen durchgeführt, mit denen größtenteils die jeweiligen Reaktionsmechanismen der Perhydrolyse von Nitrilen, Chlorameisensäureestern und Acetamid sowie von Natriumcyanat und teilweise von Benzoylsäurechloriden ermittelt werden konnten. Über den Mechanismus der erstmals von Radziszewski durchgeführten Reaktion von Wasserstoffperoxid mit Nitrilen (Radziszewski 1885) bestand bis heute noch keine endgültige Gewißheit. Es konnte nun gezeigt werden, daß im Gegensatz zu dem bisher allgemein akzeptierten Mechanismus von Wiberg (Wiberg 1953) der geschwindigkeitsbestimmende Schritt in wäßriger alkalischer Lösung der heterolytische Zerfall der intermediär gebildeten Peroxoiminosäure ist. Diese Zerfallsreaktion läuft nach einer Reaktion zweiter Ordnung ab und ist stark vorn pN-Wert abhängig. Durch die ph-Abhängigkeit konnten erstmals sowohl die pKs-Werte sowie auch die heterolytischen Zerfallskonstanten kZ, der untersuchten Peroxoiminosäuren abgeschätzt werden. In Gegenwart eines Ketons wird diese Reaktion bei Verwendung von Acetonitril stark beschleunigt. Verwendet man reaktivere Ketone wie zum Beispiel Fluoraceton wird das Zeitgesetz so komplex, daß eine quantitative Auswertung allein anhand der Singulettsauerstoffbildung nicht mehr möglich ist. Im Rahmen der Untersuchung der Nitrile wurde auch die Perhydrolyse des anorganischen Natriumcyanats in alkalischer Pufferlösung untersucht. Der hierbei gefundene Mechanismus unterscheidet sich allerdings von dem der Nitrile. In der ersten Reaktion pseudo-erster Ordnung wird die bisher unbekannte Peroxocarbaminsäure (H2N-C(O)OOH) gebildet, die dann unter Bildung von Ammoniak und dem instabilen Kohlenstoffperoxid (C03) zerfällt. Kohlenstoffperoxid (C03) wird als die Verbindung angesehen, deren Zerfall zur Bildung von Kohlenstoffdioxid und Singulettsauerstoff führt. Bei der Perhydrolyse des Acetamids im basischen Bereich konnten nur bei einem großen Überschuß an Wasserstoffperoxid auswertbare 1O2-Phosphoreszenz-Zeit-Kurven gefunden werden. Weiterhin wurde in THF die Perhydrolyse einiger Chlorameisensäureester in Abwesenheit und Gegenwart von Pyridin studiert. Die Perhydrolyse der Ester führte in Abwesenheit von Pyridin überwiegend zur Ausbildung eines konstanten 1O2-Phosphoreszenzsignal, dem Soge nannten "Chloridsignal", das eindeutig auf die in saurer Lösung durch Chloridionen katalysierte Zerfallsreaktion von Wasserstoffperoxid zurückzuführen ist. Die Induktionszeit, das heißt die Zeit nach der ein Singulettsauerstoffsignal beobachtet wird, korreliert mit der Stärke der elektronenziehenden Estergruppe. Wird die Perhydrolyse der genannten Ester in Gegenwart von Pyridin untersucht, wird die Reaktion bei dem Chlorameisensäuremethylester (CAME), dem Chlorameisensäureethylester (CAEE), dem Chlorameisensäurebenzylester (CABE) und dem Chlorameisensäure-4-nitrobenzylester (CANBE) durch Pyridin sehr stark beschleunigt. Nach Zugabe von Pyridin wird ohne lnduktionsperiode ein intensives 1O2-Phosphoreszenzsignal beobachtet, das nach einer Reaktion pseudo-erster Ordnung abklingt. Vermutlich wird bei den genannten Estern intermediär das N-Peroxocarboxylpvridiniumkation gebildet, welches auf Grund des in alpha-Stellung zur Peroxocarhoxylgruppe stehenden positiv geladenen Stickstoffatoms ein starkes Oxidationsmittel ist. Ferner wurde die Umsetzung von Säurechloriden mit Wasserstoffperoxid untersucht, bei der ebenfalls intermediär eine Peroxosäure gebildet wird, Jedoch war es nicht möglich, den Reaktionsmechanismus tatsächlich aufzuklären.
Der erste Teil der Arbeit beschäftigt sich mit dem Vergleich der Charge Transfer induzierten Prozesse bei der Löschung von Triplett angeregten Sensibilisatoren durch Sauerstoff mit den Charge Transfer induzierten Prozessen bei der Löschung von Singulettsauerstoff durch die gleichen Sensibilisatoren im Grundzustand. Dazu wurden die Geschwindigkeitskonstanten für beide Prozesse in verschiedenen Lösungsmitteln unterschiedlicher Polarität sowie notwendige photophysikalische Parameter wie Triplettenergien und Triplettquantenausbeuten bestimmt. Für eine Reihe von Naphthalin- und Biphenylderivaten kann erstmals gezeigt werden, daß die Geschwindigkeitskonstanten für beide Charge Transfer Prozesse eindeutig durch eine gemeinsame Marcus Abhängigkeit von der Freien Enthalpie für die Bildung eines Ionenpaares beschrieben werden können. Weiterhin wird am Beispiel der Naphthalinderivate gezeigt, daß die Dipolmomente der Übergangszustände der Reaktion von aus Aromat und Sauerstoff gebildeten Encounter-Komplexen zu Charge Transfer-Komplexen bei beiden Prozessen den gleichen Wert besitzen. Diese Ergebnisse werden durch einen gemeinsamen Desaktivierungskanal erklärt: beide Prozesse verlaufen über angeregte Komplexe mit der gleichen supra-supra Struktur. Dabei ergibt sich ein konsistentes Bild. Es wird gezeigt, daß der Charge Transfer Charakter für beide Prozesse im Einklang mit den Erwartungen mit steigernder Lösungsmittelpolarität ansteigt und wesentlich größer ist als bisher in der Literatur vermutet. Die Reorganisationsenergie wird für beide Prozesse in einen lösungsmittelunabhängigen intramolekularen und einen lösungsmittelabhängigen Beitrag aufgeteilt. Dabei stellt sich heraus, daß die leicht höheren Werte für die Naphthalinderivate durch höhere intramolekulare Reorganisationsenergien verursacht werden. Dies wird durch eine größere Delokalisation der aromatischen Elektronen erklärt. Ganz anders verhalten sich Benzophenonderivate. Zwar ist die Abhängigkeit der Geschwindigkeitskonstanten der Charge Transfer induzierten Löschung von O2(1Δg) durch die Benzophenonderivate im Grundzustand nahezu identisch mit der Abhängigkeit der Naphthalin- und Biphenylderivate. Jedoch weichen die Geschwindigkeitskonstanten der Charge Transfer induzierten Desaktivierung der Triplettzustände der Benzophenonderivate durch O2 enorm von der für ππ* Sensibilisatoren gefundenen gemeinsamen Korrelation ab. Hauptsächlich im endergonischen Bereich liegen die Werte um mehrere Größenordnungen höher. Andererseits wird ein wesentlich geringerer Charge Transfer Beitrag zur Geschwindigkeitskonstante festgestellt. Relativ große intramolekulare Reorganisationsenergien zeigen, daß bei der Desaktivierung der Komplexe von Triplett angeregtem Benzophenon und Sauerstoff große Änderungen der Bindungslängen stattfinden. Dies führt zu einer Verschiebung der Potentialkurve des angeregten Komplexes, verglichen mit der des Grundzustandskomplexes, und somit zu großen Franck-Condon Faktoren und zu hohen Geschwindigkeitskonstanten für die Desaktivierung in die Grundzustände im Bereich hoher Triplettenergien. Es wird gezeigt, daß die räumliche Struktur der angeregten Komplexe aus Keton und Sauerstoff für dieses Verhalten verantwortlich ist. Diese Ergebnisse führen zu einem plausiblen Mechanismus, der die niedrigen Effizienzen der Bildung von Singulettsauerstoff bei der Löschung von nπ* angeregten Ketonen erstmals zwanglos erklärt. Im zweiten Teil der Arbeit wird die Abhängigkeit der Geschwindigkeitskonstanten der Bildung von O2(1Σg+), O2(1Δg) und O2(3Σg-) bei der Löschung von ππ* angeregten Triplettzuatänden durch Sauerstoff von der Freien Enthalpie ΔGCET für die Bildung eines Ionenpaares und von der Überschußenergie ΔE für die Bildung des jeweiligen Zustands von O2 untersucht. Zur Bestimmung dieser Geschwindigkeitskonstanten wird ein Aufbau zur zeitgleichen Detektion der O2(1Σg+ 􀂤 1Δg) Fluoreszenz, der O2(1Σg+ 􀂤 3Σg-) Phosphoreszenz und der O2(1Δg 􀂤 3Σg-) Phosphoreszenz erstellt. Mit diesem Aufbau wird eine Reihe von Sensibilisatoren mit sehr unterschiedlichen Oxidationspotentialen, Triplettenergien und Strukturen in Tetrachlorkohlenstoff untersucht. Es wird gezeigt, daß die Geschwindigkeitskonstanten kT 1Σ, kT 1Δ und kT 3Σ der Bildung von O2(1Σg+), O2(1Δg) und O2(3Σg-) zusammen mit den Werten für alle bisher mit der gleichen Methode untersuchten Sensibilisatoren durch eine gemeinsame Abhängigkeit von ΔGCET und ΔE beschrieben werden können. Dies bedeutet, daß kT 1Σ, kT 1Δ und kT 3Σ hauptsächlich durch die Triplettenergie und das Oxidationspotential des Sensibilisators bestimmt werden, und daß die Variation der molekularen Struktur nur eine untergeordnete Rolle spielt. Damit wird es zum ersten Mal möglich, die Geschwindigkeitskonstanten der Bildung von O2(1Σg+), O2(1Δg) und O2(3Σg-) bei der Löschung von ππ* Triplettzuständen durch Sauerstoff in Tetrachlorkohlenstoff für beliebige Sensibilisatoren mit hinreichender Genauigkeit vorauszusagen.
The Compressed Baryonic Matter (CBM) is one of the core experiments at the future Facility for Anti-proton and Ion Research (FAIR), Darmstadt, Germany. Its goal is to investigate nuclear matter characteristics at high net-baryon densities and moderate temperatures. The Silicon Tracking System (STS) is a central detector system of CBM.
It is placed inside a 1Tm magnet and operated at a temperature of about −10 °C to keep radiation-induced bulk current in the 300μm double-sided microstrip silicon sensors low. The design of the STS aims to minimize the material budget in the detector acceptance (2.5° < θ < 25°). In order to do so, the readout electronics is placed outside the active area, and the analog signals are transported via ultra-thin micro-cables. The STS comprises eight tracking stations with 876 modules. Each module is assembled on a carbon fiber ladder, which is subsequently mounted in the C-shaped aluminum frame.
The scope of the thesis focused on developing a modular control system framework that can be implemented for different sizes of experimental setups. The developed framework was used for setups that required a remote operation, like the irradiation of the powering modules for the front-end electronics (FEE), but also in laboratory-based setups where the automation and archiving were needed (thermal cycling of the STS electronics).
The low voltage powering modules will be placed in the vicinity of the experiment, therefore they will experience a total dose of up to 40mGy over the 10 years of STS lifetime.
To estimate the effects of the radiation on the low-voltage module performance, a dedicated irradiation campaign took place. It aimed at estimating the rate of radiation induced soft errors, that lead to the switch off of the FEE.
Regular power cycles of multiple front-end boards (FEBs) pose a risk to the experiment operation. Firstly, such behavior could negatively influence the physics performance but also have deteriorating effects on the hardware. It was further assessed what are the limitations of the FEBs with respect to the thermal cycling and the mechanical stress. The results served as an indication of possible failure modes of the FEB at the end of STS lifetime. Failure modes after repeated cycles and potential reasons were determined (e.g., Coefficient of Thermal Expansion (CTE) difference between the materials).
Due to the conditions inside the STS efficient temperature and humidity monitoring and control are required to avoid icing or water condensation on the electronics or silicon sensors. The most important properties of a suitable sensor candidate are resilience to the magnetic field, ionizing radiation tolerance, and fairly small size.
A general strategy for ambient parameters monitoring inside the STS was developed, and potential sensor candidates were chosen. To characterize the chosen relative humidity sensors the developed control framework was introduced. A sampling system with a ceramic sensor and Fiber Optic Sensors (FOS) were identified as reliable solutions for the distributed sensing system. Additionally, the industrial capacitive sensors will be used as a reference during the commissioning.
Two different designs of FOS were tested: a hygrometer and 5 sensors multiplexed in an array. The FOS hygrometer turned out to be a more reliable solution. One of the possible reasons for a worse performance is a relatively low distance between the subsequent sensors (15 cm) and a thicker coating. The results obtained from the time response study pointed out that the thinner coating of about 15μm should be a good compromise between the humidity sensitivity and the time response.
The implementation of the containerized-based control system framework for the mSTS is described in detail. The deployed EPICS-based framework proved to be a reliable solution and ensured the safety of the detector for almost 1.5 years. Moreover, the data related to the performance of the detector modules were analyzed and significant progress in the quality of modules was noted. Obtained data was also used to estimate the total fluence, which was based on the leakage current changes.
The developed framework provided a unique opportunity to automate and control different experimental setups which provided crucial data for the STS. Furthermore, the work underlines the importance of such a system and outlines the next steps toward the realization of a reliable Detector Control System for STS.