TY - JOUR A1 - Doss, Mirko A1 - Wood, Jeffrey P. A1 - Kiessling, Arndt Holger A1 - Moritz, Anton T1 - Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis T2 - Journal of cardiothoracic surgery N2 - Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods: One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age < 55 years), either stentless bioprosthesis (CE Prima Plus n = 20) or MP (Edwards Mira n = 20) in group 2 (age 55-75 years) and either stentless (CE Prima Plus n = 20) or stented bioprosthesis (CE Perimount n = 20) in group 3 (age > 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results: In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions: Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs. KW - Left Ventricular Mass KW - Aortic Valve Replacement KW - Prospective randomized Analysis Y1 - 2011 UR - http://publikationen.ub.uni-frankfurt.de/frontdoor/index/index/docId/22809 UR - https://nbn-resolving.org/urn:nbn:de:hebis:30:3-228096 UR - http://www.cardiothoracicsurgery.org/content/6/1/136 SN - 1749-8090 N1 - © 2011 Doss et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. VL - 6 IS - 136 SP - 1 EP - 8 PB - BioMed Central CY - London ER -