TY - JOUR A1 - Lauber, Simone F. A1 - Aulenbacher, Kurt A1 - Barth, Winfried A1 - Basten, Markus A1 - Burandt, Christoph A1 - Dziuba, Florian A1 - Forck, Peter A1 - Gettmann, Viktor A1 - Heilmann, Manuel A1 - Kürzeder, Thorsten A1 - List, Julian A. A1 - Miski-Oglu, Maksym A1 - Podlech, Holger A1 - Rubin, Anna A1 - Schwarz, Malte A1 - Sieber, Thomas A1 - Yaramyshev, Stepan T1 - A dynamic collimation and alignment system for the Helmholtz linear accelerator T2 - Review of Scientific Instruments N2 - The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements. Y1 - 2021 UR - http://publikationen.ub.uni-frankfurt.de/frontdoor/index/index/docId/81902 UR - https://nbn-resolving.org/urn:nbn:de:hebis:30:3-819020 SN - 0034-6748 VL - 92 IS - 11, art. 113306 SP - 1 EP - 9 ER -