• search hit 2 of 3
Back to Result List

Time resolved measurements of the biased disk effect at an Electron Cyclotron Resonance Ion Source

  • First results are reported from time resolved measurements of ion currents extracted from the Frankfurt 14 GHz Electron Cyclotron Resonance Ion Source with pulsed biased-disk voltage. It was found that the ion currents react promptly to changes of the bias. From the experimental results it is concluded that the biased disk effect is mainly due to improvements of the extraction conditions for the source and/or an enhanced transport of ions into the extraction area. By pulsing the disk voltage, short current pulses of highly charged ions can be generated with amplitudes significantly higher than the currents obtained in continuous mode.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Kurt E. Stiebing, Oliver HohnGND, Steffen Runkel, Lothar Schmidt, Horst Schmidt-BöckingGND, Victor L. Mironov, Grigorij D. Širkov
URN:urn:nbn:de:hebis:30:3-442162
DOI:https://doi.org/10.1103/PhysRevSTAB.2.123501
ISSN:1098-4402
Parent Title (German):Physical Review Special Topics. Accelerators and Beams
Publisher:American Physical Society
Place of publication:[S.l.]
Document Type:Article
Language:English
Year of Completion:2017
Date of first Publication:1999/12/10
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2017/06/07
Volume:2
Issue:12, 123501
Note:
This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
HeBIS-PPN:425116387
Institutes:Physik / Physik
Dewey Decimal Classification:5 Naturwissenschaften und Mathematik / 53 Physik / 530 Physik
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - Namensnennung 3.0