• search hit 2 of 17
Back to Result List

Potential of high dimensional radiomic features to assess blood components in intraaortic vessels in non-contrast CT scans

  • Background: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. Methods: One hundred patients (median age, 69 years; range, 19–94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). Results: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). Conclusions: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Scherwin MahmoudiGND, Simon MartinORCiDGND, Jörg AckermannORCiDGND, Yauheniya Zhdanovich, Ina KochORCiD, Thomas J. VoglORCiDGND, Moritz Hans Ernst AlbrechtORCiDGND, Lukas Fabian LengaORCiDGND, Simon BernatzORCiDGND
URN:urn:nbn:de:hebis:30:3-626224
DOI:https://doi.org/10.1186/s12880-021-00654-9
ISSN:1471-2342
Parent Title (English):BMC medical imaging
Publisher:BioMed Central
Place of publication:London
Document Type:Article
Language:English
Date of Publication (online):2021/08/12
Date of first Publication:2021/08/12
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2021/11/02
Tag:Anemia; Artificial intelligence; Blood; CT; Radiomics
Volume:21
Issue:art. 123
Page Number:10
First Page:1
Last Page:10
Note:
The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
Open Access funding enabled and organized by Projekt DEAL.
HeBIS-PPN:489040624
Institutes:Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - Namensnennung 4.0