• search hit 1 of 1
Back to Result List

Saving of time using a software-based versus a manual workflow for toric intraocular lens calculation and implantation

  • Background: To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time. Methods: In total, 48 eyes of 24 patients were divided into two groups: 24 eyes were evaluated using a manual approach, whereas another 24 eyes underwent a full digital lens surgery workflow. The primary variables for comparison between both groups were the overall time as well as several time steps starting at optical biometry acquisition until the end of the surgical lens implantation. Other outcomes, such as toric intraocular lens misalignment, reduction of cylinder, surgically induced astigmatism, prediction error, and distance visual acuity were measured. Results: Overall, the total diagnostic and surgical time was reduced from 1364.1 ± 202.6 s in the manual group to 1125.8 ± 183.2 s in the digital group (p < 0.001). The complete time of surgery declined from 756.5 ± 82.3 s to 667.3 ± 56.3 (p < 0.0005). Compared to the manual approach of biometric data export and intraocular lens calculation (76.7 ± 12.3 s) as well as the manual export of the reference image to a portable external storage device (26.8 ± 5.5 s), a highly significant saving of time was achieved (p < 0.0001). Conclusions: Using a software-based digital approach to toric intraocular lens implantation is convenient, more efficient, and thus more economical than a manual workflow in surgery practice.

Download full text files

Export metadata

Metadaten
Author:Barbara S. Brunner, Nikolaus LuftGND, Siegfried PriglingerORCiDGND, Mehdi ShajariGND, Wolfgang J. MayerGND, Stefan KassumehORCiDGND
URN:urn:nbn:de:hebis:30:3-692457
DOI:https://doi.org/10.3390/jcm11102907
ISSN:2077-0383
Parent Title (English):Journal of Clinical Medicine
Publisher:MDPI
Place of publication:Basel
Document Type:Article
Language:English
Date of Publication (online):2022/05/20
Date of first Publication:2022/05/20
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2022/12/19
Tag:cataract surgery; cataract surgery workflow; clear lens exchange; efficiency; refractive lens exchange; refractive surgery; toric intraocular lens
Volume:11
Issue:10, art. 2907
Article Number:2907
Page Number:7
First Page:1
Last Page:7
Note:
Funding
This study 1890-21 (310) has been funded by an unrestricted research Grant from Carl Zeiss Meditec, Inc. The funders had no role in study design, data collection, analysis, decision to publish, or manuscript preparation.
Institutes:Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - CC BY - Namensnennung 4.0 International