Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms

  • Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model. Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation. Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon. Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Metadaten
Author:Vitali KochORCiDGND, Gerald LoosGND, Leon David GrünewaldORCiDGND, Katrin EichlerGND, Christian BoozORCiDGND, Tommaso D’AngeloORCiD, Ibrahim YelORCiDGND, Scherwin MahmoudiORCiDGND, Simon S. MartinORCiDGND, Marc HarthORCiDGND, Moritz Hans Ernst AlbrechtORCiDGND, Stephan ZangosGND, Simon BernatzORCiDGND, Axel Thalhammer, Jan-Erik ScholtzGND, Thomas J. VoglORCiDGND, Tatjana Gruber-RouhORCiDGND
URN:urn:nbn:de:hebis:30:3-783530
DOI:https://doi.org/10.1016/j.ejro.2022.100427
ISSN:2352-0477
Parent Title (English):European journal of radiology open
Publisher:Elsevier Science
Place of publication:Amsterdam [u.a.]
Document Type:Article
Language:English
Date of Publication (online):2022/06/16
Date of first Publication:2022/06/16
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2024/08/08
Tag:Computed tomography; Diagnostic accuracy; Endovascular aortic repair; Thoracic aortic aneurysm; Workstation comparison
Volume:9
Issue:art. 100427
Article Number:100427
Page Number:8
First Page:1
Last Page:8
Note:
Gefördert durch den Open-Access-Publikationsfonds der Goethe-Universität.
HeBIS-PPN:520822285
Institutes:Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Open-Access-Publikationsfonds:Medizin
Licence (German):License LogoCreative Commons - CC BY - Namensnennung 4.0 International