Tensiomyography measures the radial displacement of a muscle during an electrically evoked twitch contraction. The rate of muscle displacement is increasingly reported to assess contractile properties. Several formulas currently exist to calculate the rate of displacement during the contraction phase of the maximal twitch response. However, information on the reproducibility of these formulas is scarce. Further, different rest intervals ranging from 10 s to 30 s are applied between consecutive stimuli during progressive electrical stimulation until the maximum twitch response. The effect of different rest intervals on the rate of displacement has not been investigated so far. The first aim of this study is to investigate the within and between-day reliability of the most frequently used formulas to calculate the rate of displacement. The second aim is to investigate the effect of changing the inter-stimulus interval on the rate of displacement. We will determine the rectus femoris and biceps femoris rate of displacement of twenty-four healthy subjects’ dominant leg on two consecutive days. The maximum displacement curve will be determined two times within three minutes on the first day and a third time 24 h later. On day two, we will also apply three blocks of ten consecutive stimuli at a constant intensity of 50 mA. Inter-stimuli intervals will be 10 s, 20 s or 30 s in each block, respectively, and three minutes between blocks. The order of inter-stimulus intervals will be randomized. This study will allow a direct comparison between the five most frequently used formulas to calculate the rate of displacement in terms of their reproducibility. Our data will also inform on the effect of different inter-stimulus intervals on the rate of displacement. These results will provide helpful information on methodical considerations to determine the rate of displacement and may thus contribute to a standardized approach.
Objectives: Combined electric-acoustic stimulation (EAS) is a well-accepted therapeutic treatment for cochlear implant (CI) users with residual hearing in the low frequencies but severe to profound hearing loss in the high frequencies. The recently introduced SONNETeas audio processor offers different microphone directionality (MD) settings and wind noise reduction (WNR) as front-end processing. The aim of this study was to compare speech perception in quiet and noise between two EAS audio processors DUET 2 and SONNETeas, to assess the impact of MD and WNR on speech perception in EAS users in the absence of wind. Furthermore, subjective rating of hearing performance was registered.
Method: Speech perception and subjective rating with SONNETeas or DUET 2 audio processor were assessed in 10 experienced EAS users. Speech perception was measured in quiet and in a diffuse noise setup (MSNF). The SONNETeas processor was tested with three MD settings omnidirectional/natural/adaptive and with different intensities of WNR. Subjective rating of auditory benefit and sound quality was rated using two questionnaires.
Results: There was no significant difference between DUET 2 and SONNETeas processor using the omnidirectional microphone in quiet and in noise. There was a significant improvement in SRT with MD settings natural (2.2 dB) and adaptive (3.6 dB). No detrimental effect of the WNR algorithm on speech perception was found in the absence of wind. Sound quality was rated as “moderate” for both audio processors.
Conclusions: The different MD settings of the SONNETeas can provide EAS users with better speech perception compared to an omnidirectional microphone. Concerning speech perception in quiet and quality of life, the performance of the DUET 2 and SONNETeas audio processors was comparable.