Filtern
Dokumenttyp
Sprache
- Englisch (2)
Volltext vorhanden
- ja (2)
Gehört zur Bibliographie
- nein (2)
Institut
- Medizin (2)
Background: Intestinal perforation or leakage increases morbidity and mortality of surgical and endoscopic interventions. We identified criteria for use of full-covered, extractable self-expanding metal stents (cSEMS) vs. "Over the scope"-clips (OTSC) for leak closure.
Methods: Patients who underwent endoscopic treatment for postoperative leakage, endoscopic perforation, or spontaneous rupture of the upper gastrointestinal tract between 2006 and 2013 were identified at four tertiary endoscopic centers. Technical success, outcome (e.g. duration of hospitalization, in-hospital mortality), and complications were assessed and analyzed with respect to etiology, size and location of leakage.
Results: Of 106 patients (male: 75 (71%), female: 31 (29%); age (mean ± SD): 62.5 ± 1.3 years, 72 (69%) were treated by cSEMS and 34 (31%) by OTSC. For cSEMS vs. OTSC, mean treatment duration was 41.1 vs. 25 days, p<0.001, leakage size 10 (1-50) vs. 5 (1-30) mm (median (range)), and complications were observed in 68% vs. 8.8%, p<0.001, respectively. Clinical success for primary interventional treatment was observed in 29/72 (40%) vs. 24/34 (70%, p = 0.006), and clinical success at the end of follow-up was 46/72 (64%) vs. 29/34 (85%) for patients treated by cSEMS vs. OTSC; p = 0.04.
Conclusion: OTSC is preferred in small-sized lesions and in perforation caused by endoscopic interventions, cSEMS in patients with concomitant local infection or abscess. cSEMS is associated with a higher frequency of complications. Therefore, OTSC might be preferred if technically feasible. Indication criteria for cSEMS vs. OTSC vary and might impede design of randomized studies.
Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis
(2017)
Background: Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA.
Aim: To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS.
Methods: Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded.
Results: At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month.
Conclusions: The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions.