TY - JOUR A1 - Spyrantis, Andrea A1 - Woebbecke, Tirza A1 - Rueß, Daniel Friedrich A1 - Constantinescu, Anne A1 - Gierich, Andreas A1 - Luyken, Klaus A1 - Visser-Vandewalle, Veerle A1 - Herrmann, Eva A1 - Geßler, Florian A1 - Czabanka, Marcus Alexander A1 - Treuer, Harald A1 - Ruge, Maximilian Ingolf A1 - Freiman, Thomas Michael T1 - Accuracy of robotic and frame-based stereotactic neurosurgery in a phantom model T2 - Frontiers in neurorobotic N2 - Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum. Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated. Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41–0.55 mm) compared to 0.72 mm (95% CI 0.63–0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was −0.22 mm (95% CI −0.25 to −0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32–0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to −0.20 mm (95% CI −0.26 to −0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55–0.74 mm). Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy. KW - stereotactic neurosurgery KW - robot-guided stereotaxy KW - phantom study KW - mechanical accuracy KW - stereotactic frame Y1 - 2022 UR - http://publikationen.ub.uni-frankfurt.de/frontdoor/index/index/docId/62046 UR - https://nbn-resolving.org/urn:nbn:de:hebis:30:3-620469 SN - 1662-5218 VL - 16 IS - art. 762317 SP - 1 EP - 8 PB - Frontiers Research Foundation CY - Lausanne ER -