TY - CONF A1 - Hülsmann, Peter A1 - Kurz, Martin A1 - Glock, Hans-Walter A1 - Müller, Wolfgang F. O. A1 - Peschke, Claudius A1 - Klein, Horst T1 - Quality factor measurements in cavities with mode overlap T2 - European Particle Accelerator Conference, London: 27.06. - 01.07.1994 N2 - A new method of measuring quality factors in cavities is presented. This method is well suited to measure quality factors in undamped cavities as well as in heavily damped cavities, and in addition this method provides a possibility of separating modes and measuring quality factors especially in cases of overlapping modes. Measurements have been carried out on HOM-damped cavities for the DESY/THD linear collider project. Results are presented. Y1 - 1999 UR - http://publikationen.ub.uni-frankfurt.de/frontdoor/index/index/docId/3364 UR - https://nbn-resolving.org/urn:nbn:de:hebis:30-20487 UR - http://sunkist.physik.uni-frankfurt.de/mikro/publications.html ER -