Aims: Preventing hospitalization by detecting early evidence of heart failure (HF) decompensation in an outpatient setting can improve patient's quality of life and reduce costs of care. The purpose of this study was to assess the value of cardiac acoustic biomarkers (CABs), a combination of cardiohaemic vibrations synchronized with ECG signals, and heart rate (HR) for detecting HF decompensation during first 3 months after hospital discharge for HF.
Methods and results: Patients with an ejection fraction ≤35% (HFrEF) and hospitalized for decompensated HF were enrolled in a prospective observational study. All subjects wore a wearable cardioverter‐defibrillator (ZOLL LifeVest®, Pittsburgh, PA, USA) that is capable of recording CABs and HR. The primary endpoint of the study was the first HF event, defined as HF readmission or HF emergency room visit. From June 2017 through August 2019, 671 patients with HFrEF were enrolled. Eighty‐one patients (12.1%) had a total of 112 HF events. The algorithm detected HF events with a median of 32 days (interquartile range = 11‐45) in advance of the first HF event. The algorithm had a sensitivity of 69%, specificity of 60%, positive predictive value of 19%, and a negative predictive value of 94%. Of note, the baseline (first 7 days post‐enrolment) algorithm using CABs and HR was superior to New York Heart Association classification in detecting patients more likely to have HF decompensation (sensitivity and specificity of 61% and 68% vs. 46% and 55%, respectively).
Conclusions: This prospective international registry showed that an algorithm incorporating CABs and HR data detected HF events 30 days in advance of the event in patients with HFrEF during first 3 months after hospital discharge. Therefore, integrating CAB technology into clinical practice may prevent HF rehospitalizations.
Objectives: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions.
Background: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far.
Methods: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure.
Results: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients.
Conclusions: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.