Refine
Document Type
- Article (6)
Language
- English (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
Institute
- Medizin (6)
Background: Despite a large body of evidence demonstrating the effectiveness of psychotherapy for posttraumatic stress for children and adolescents, the adoption of empirically supported treatments (ESTs) in routine care is low.
Objective: This implementation study aims to evaluate the dissemination of Trauma-Focused Cognitive Behavioural Therapy (TF-CBT) for children and adolescents with posttraumatic stress symptoms (PTSS) after child abuse and neglect (CAN) with a focus on supervision.
Method: In a cluster-randomized controlled trial, the study will evaluate the implementation of TF-CBT focussing on the training of therapists including the provision of supervision. The effectiveness of specialized trauma-focused supervision will be compared to supervision as usual with respect to the successful implementation of TF-CBT for youths with PTSS administered by psychotherapists with different levels of professional experience. The primary outcome is whether the patient receives a treatment with sufficient adherence to the TF-CBT manual. The unit of randomization will be the therapists. The main outcome will be analysed using multilevel logistic regressions. Secondary outcomes will concern further patient-related (reduction of PTSS and depressive symptoms) and therapist-related (professional quality of life) variables. Additional exploratory analyses are planned.
Discussion: Since the trial is designed as an implementation study, it permits naturalistic referrals to the participating therapists by patients, caregivers, child and youth welfare agencies and paediatricians. The strict primary outcome will help evaluating the role of model-based supervision in the implementation process. The explorative outcomes will evaluate whether implementation success translates into better patient outcomes. We expect that the dissemination measures will lead to a successful implementation of TF-CBT and promote sustainable structures in routine care that will remain in place after study completion and offer access to ESTs for future children and youths with a history of CAN.
Background: The spontaneously diabetic “non-obese diabetic” (NOD) mouse is a faithful model of human type-1 diabetes (T1D). Methods: Given the pivotal role of α4 integrin (CD49d) in other autoimmune diseases, we generated NOD mice with α4-deficient hematopoiesis (NOD.α4-/-) to study the role of α4 integrin in T1D. Results: NOD.α4-/- mice developed islet-specific T-cells and antibodies, albeit quantitatively less than α4+ counterparts. Nevertheless, NOD.α4-/- mice were completely and life-long protected from diabetes and insulitis. Moreover, transplantation with isogeneic α4-/- bone marrow prevented progression to T1D of pre-diabetic NOD.α4+ mice despite significant pre-existing islet cell injury. Transfer of α4+/CD3+, but not α4+/CD4+ splenocytes from diabetic to NOD.α4-/- mice induced diabetes with short latency. Despite an only modest contribution of adoptively transferred α4+/CD3+ cells to peripheral blood, pancreas-infiltrating T-cells were exclusively graft derived, i.e., α4+. Microbiota of diabetes-resistant NOD.α4-/- and pre-diabetic NOD.α4+ mice were identical. Co- housed diabetic NOD.α4+ mice showed the characteristic diabetic dysbiosis, implying causality of diabetes for dysbiosis. Incidentally, NOD.α4-/- mice were protected from autoimmune sialitis. Conclusion: α4 is a potential target for primary or secondary prevention of T1D.
Abstract: Neurophysiological measures of preparation and attention are often atypical in ADHD. Still, replicated findings that these measures predict which patients improve after Neurofeedback (NF), reveal neurophysiological specificity, and reflect ADHD-severity are limited. Methods: We analyzed children’s preparatory (CNV) and attentional (Cue-P3) brain activity and behavioral performance during a cued Continuous Performance Task (CPT) before and after slow cortical potential (SCP)-NF or semi-active control treatment (electromyogram biofeedback). Mixed-effects models were performed with 103 participants at baseline and 77 were assessed for pre-post comparisons focusing on clinical outcome prediction, specific neurophysiological effects of NF, and associations with ADHD-severity. Results: Attentional and preparatory brain activity and performance were non-specifically reduced after treatment. Preparatory activity in the SCP-NF group increased with clinical improvement. Several performance and brain activity measures predicted non-specific treatment outcome. Conclusion: Specific neurophysiological effects after SCP-NF were limited to increased neural preparation associated with improvement on ADHD-subscales, but several performance and neurophysiological measures of attention predicted treatment outcome and reflected symptom severity in ADHD. The results may help to optimize treatment.
Background: MicroRNAs circulating in the blood, stabilized by complexation with proteins and/or additionally by encapsulation in lipid vesicles, are currently being evaluated as biomarkers. The consequences of their differential association with lipids/vesicles for their stability and use as biomarkers are largely unexplored and are subject of the present study.
Methods: The levels of a set of selected microRNAs were determined by quantitative reverse-transcription PCR after extraction from sera or vesicle- and non-vesicle fractions prepared from sera. The stability of these microRNAs after incubation with RNase A or RNase inhibitor, an inhibitor of RNase A family enzymes was studied.
Results: The levels of microRNA-1 and microRNA-122, but not those of microRNA-16, microRNA-21 and microRNA-142-3p, declined significantly during a 5-h incubation of the sera. RNase inhibitor prevented the loss of microRNAs in serum as well as the degradation of microRNA-122, a microRNA not expressed in blood cells, in whole blood. Stabilization of microRNA-122 was also achieved by hemolysis. Prolonged incubation of the sera led to enrichment of vesicle-associated relative to non-vesicle-associated microRNAs. Vesicle-associated microRNAs were more resistant to RNase A treatment than the respective microRNAs not associated with vesicles.
Conclusions: Serum microRNAs showed differential stability upon prolonged incubation. RNase inhibitor might be useful to robustly preserve the pattern of cell-free circulating microRNAs. In the case of microRNAs not expressed in blood cells this can also be achieved by hemolysis. Vesicle-associated microRNAs appeared to be more stable than those not associated with vesicles, which might be useful to disclose additional biomarker properties of miRNAs.
Background: To evaluate clinical outcomes after either immediate or deferred initiation of antiretroviral therapy in HIV-1-infected patients, presenting late with pneumocystis pneumonia (PCP) or toxoplasma encephalitis (TE).
Methods: Phase IV, multicenter, prospective, randomized open-label clinical trial. Patients were randomized into an immediate therapy arm (starting antiretroviral therapy (ART) within 7 days after initiation of OI treatment) versus a deferred arm (starting ART after completing the OI-therapy). All patients were followed for 24 weeks. The rates of clinical progression (death, new or relapsing opportunistic infections (OI) and other grade 4 clinical endpoints) were compared, using a combined primary endpoint. Secondary endpoints were hospitalization rates after completion of OI treatment, incidence of immune reconstitution inflammatory syndrome (IRIS), virologic and immunological outcome, adherence to proteinase-inhibitor based antiretroviral therapy (ART) protocol and quality of life.
Results: 61 patients (11 patients suffering TE, 50 with PCP) were enrolled. No differences between the two therapy groups in all examined primary and secondary endpoints could be identified: immunological and virologic outcome was similar in both groups, there was no significant difference in the incidence of IRIS (11 and 10 cases), furthermore 9 events (combined endpoint of death, new/relapsing OI and grade 4 events) occurred in each group.
Conclusions: In summary, this study supports the notion that immediate initiation of ART with a ritonavir-boosted proteinase-inhibitor and two nucleoside reverse transcriptase inhibitors is safe and has no negative effects on incidence of disease progression or IRIS, nor on immunological and virologic outcomes or on quality of life.
Purpose: High precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.
Methods and material: Preliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference ⩽ 2%, distance-to-agreement ⩽ 2 mm, pass-rate ⩾ 90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1 mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.
Results: The 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10 cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1 mm distance-to-agreement criterion while 2 mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.
Conclusion: We demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response.