BACKGROUND: Recent findings support the idea that interleukin (IL)-22 serum levels are related to disease severity in end-stage liver disease. Existing scoring systems--Model for End-Stage Liver Disease (MELD), Survival Outcomes Following Liver Transplantation (SOFT) and Pre-allocation-SOFT (P-SOFT)--are well-established in appraising survival rates with or without liver transplantation. We tested the hypothesis that IL-22 serum levels at transplantation date correlate with survival and potentially have value as a predictive factor for survival.
MATERIAL AND METHODS: MELD, SOFT, and P-SOFT scores were calculated to estimate post-transplantation survival. Serum levels of IL-22, IL-6, IL-10, C-reactive protein (CRP), and procalcitonin (PCT) were collected prior to transplantation in 41 patients. Outcomes were assessed at 3 months, 1 year, and 3 years after transplantation.
RESULTS: IL-22 significantly correlated with MELD, P-SOFT, and SOFT scores (Rs 0.35, 0.63, 0.56 respectively, p<0.05) and with the discrimination in post-transplantation survival. IL-6 showed a heterogeneous pattern (Rs 0.40, 0.63, 0.57, respectively, p<0.05); CRP and PCT did not correlate. We therefore added IL-22 serum values to existing scoring systems in a generalized linear model (GLM), resulting in a significantly improved outcome prediction in 58% of the cases for both the P-SOFT (p<0.01) and SOFT scores (p<0.001).
CONCLUSIONS: Further studies are needed to address the concept that IL-22 serum values at the time of transplantation provide valuable information about survival rates following orthotopic liver transplantation.
Background: Lung ultrasound has become an emerging tool in acute and critical care medicine. Combined theoretical and hands-on training has been required to teach ultrasound diagnostics. Current computer technology allows for display, explanation, and animation of information in a remote-learning environment.
Objective: Development and assessment of an e-learning program for lung ultrasound.
Methods: An interactive online tutorial was created. A prospective learning success study was conducted with medical students using a multiple-choice test (Trial A). This e-learning program was used as preparation for a certified course followed by an evaluation of trained doctors (Trial B) by linear analogue scales. Pretests were compared with postcourse tests and sustainability tests as well as a posttest of a one-day custom classroom training.
Results: In Trial A, during the learning success study (n = 29), the increase of correct answers was 11.7 to 17/20 in the post-test and to 16.6/20 in the sustainability test (relative change 45.1%, P < 0.0001). E-learning almost equalled scores of classroom-based training regarding gain and retention of factual knowledge. In Trial B, nineteen participating doctors found a 79.5% increase of knowledge (median, 95% CI: 69%; 88%).
Conclusion: The basics of lung ultrasound can be taught in a highly effective manner using e-learning.
Objective. Evaluation of C-MAC PM® in combination with a standard Macintosh blade size 3 in direct and indirect laryngoscopy and D-Blade® in indirect laryngoscopy in a simulated difficult airway. Primary outcome was defined as the best view of the glottic structures. Secondary endpoints were subjective evaluation and assessment of the intubation process.
Methods. Prospective monocentric, observational study on 48 adult patients without predictors for difficult laryngoscopy/tracheal intubation undergoing orthopedic surgery. Every participant preoperatively received a cervical collar to simulate a difficult airway. Direct and indirect laryngoscopy w/o the BURP maneuver with a standard Macintosh blade and indirect laryngoscopy w/o the BURP maneuver using D-Blade® were performed to evaluate if blade geometry and the BURP maneuver improve the glottic view as measured by the Cormack-Lehane score.
Results. Using a C-MAC PM® laryngoscope, D-Blade® yielded improved glottic views compared with the Macintosh blade used with either the direct or indirect technique. Changing from direct laryngoscopy using a Macintosh blade to indirect videolaryngoscopy using C-MAC PM® with D-Blade® improved the Cormack-Lehane score from IIb, III, or IV to I or II in 31 cases.
Conclusion. The combination of C-MAC PM® and D-Blade® significantly enhances the view of the glottis compared to direct laryngoscopy with a Macintosh blade in patients with a simulated difficult airway.
Trial Registration Number. This trial is registered under number NCT03403946.
Objective. To test the influence of personalized ultrasound (PersUS) on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Patients and Interventions. 640 patient ultrasound exams including 548 focused diagnostic exams and 92 interventional procedures. Main Outcome Measures. Number of studies, physician’s judgement of feasibility, time of usage per patient, and referrals to echo lab. Results. Randomized availability of PersUS increased its application in ICU work shifts more than twofold from 33 to 68 exams mainly for detection and therapy of effusions. Diagnostic and procedural quality was rated as excellent/very good in PersUS-guided puncture in 95% of cases. Integrating PersUS within an initial physical examination of 48 randomized cases in an emergency department, PersUS extended the examination time by 100 seconds. Interestingly, PersUS integration into 53 randomized regular ward rounds of 1007 patients significantly reduced average contact time per patient by 103 seconds from 8.9 to 7.2 minutes. Moreover, it lowered the patient referral rate to an echo lab from 20% to 2% within the study population. Conclusions. We propose the development of novel ultrasound-based clinical pathways by integration of PersUS.
OBJECTIVE: The role of supraglottic airway devices in emergency airway management is highlighted in international airway management guidelines. We evaluated the application of the new generation laryngeal tube suction (LTS-II/LTS-D) in the management of in-hospital unexpected difficult airway and cardiopulmonary resuscitation.
METHODS: During a seven-year period, patients treated with a laryngeal tube who received routine anesthesia and had an unexpected difficult airway (Cormack Lehane Grade 3-4), who underwent cardiopulmonary resuscitation, or who underwent cardiopulmonary resuscitation outside the operating room and had a difficult airway were evaluated. Successful placement of the LTS II/LTS-D, sufficient ventilation, time to placement, number of placement attempts, stomach content, peripheral oxygen saturation/end-tidal carbon dioxide development (SpO2/etCO2) over 5 minutes, subjective overall assessment and complications were recorded.
RESULTS: In total, 106 adult patients were treated using an LTS-II/LTS-D. The main indication for placement was a difficult airway (75%, n=80), followed by cardiopulmonary resuscitation (25%, n=26) or an overlap between both (18%, n=19). In 94% of patients (n=100), users placed the laryngeal tube during the first attempt. In 93% of patients (n=98), the tube was placed within 30 seconds. A significant increase in SpO2 from 97% (0-100) to 99% (5-100) was observed in the whole population and in cardiopulmonary resuscitation patients. The average initial etCO2 of 39.5 mmHg (0-100 mmHg) decreased significantly to an average of 38.4 mmHg (10-62 mmHg) after 5 minutes. A comparison of cardiopulmonary resuscitation patients with non-cardiopulmonary resuscitation patients regarding gastric contents showed no significant difference.
CONCLUSIONS: LTS-D/LTS-II use for in-hospital unexpected difficult airway management provides a secure method for primary airway management until other options such as video laryngoscopy or fiber optic intubation become available.