- Physik (6)
Recently the Universal Linear Accelerator (UNILAC) serves as a powerful high duty factor (25%) heavy ion beam accelerator for the ambitious experiment program at GSI. Beam time availability for SHE (Super Heavy Element)-research will be decreased due to the limitation of the UNILAC providing Uranium beams with an extremely high peak current for FAIR simultaneously. To keep the GSI-SHE program competitive on a high level and even beyond, a standalone superconducting continuous wave (100% duty factor) LINAC in combination with the upgraded GSI High Charge State injector is envisaged. In preparation for this, the first LINAC section (financed by HIM and GSI) will be tested with beam in 2017, demonstrating the future experimental capabilities. Further on the construction of an extended cryo module comprising two shorter Crossbar-H cavities is foreseen to test until end of 2017. As a final R&D step towards an entire LINAC three advanced cryo modules, each comprising two CH cavities, should be built until 2019, serving for first user experiments at the Coulomb barrier.
At the Institute for Applied Physics (IAP), University of Frankfurt, a s.c. 325 MHz CH-Cavity is under development for future beam tests at GSI UNILAC, Darmstadt. The cavity with 7 accelerating cells has a geometrical beta of 0.15 corresponding to 11.4 AMeV. The design gradient is 5 MV/m. The geometry of this resonator was optimized with respect to a compact design, low peak fields, surface processing, power coupling and tuning. Furthermore a new tuning system based on bellow tuners inside the resonator will control the frequency during operation. After rf tests in Frankfurt the cavity will be tested with a 10 mA, 11.4 AMeV beam delivered by the GSI UNILAC. In this paper rf simulations, multipacting analysis as well as thermal calculations will be presented.
At GSI a new, superconducting (sc) continuous wave (cw) LINAC is under design in cooperation with the Institute for Applied Physics (IAP) of Frankfurt University and the Helmholtz Institut Mainz (HIM). This proposed LINAC is highly requested by a broad community of future users to fulfill the requirements of nuclear chemistry, nuclear physics, and especially in the research field of Super Heavy Elements (SHE). In this context the preliminary layout of the LINAC has been carried out by IAP. The main acceleration of up to 7.3 AMeV will be provided by nine sc Crossbar-H-mode (CH) cavities operated at 217 MHz. Currently, a prototype of the cw LINAC as a demonstrator is under development. The demonstrator comprises a sc CH-cavity embedded between two sc solenoids mounted in a horizontal cryomodule. A full performance test of the demonstrator in 2013/14 by injecting and accelerating a beam from the GSI High Charge Injector (HLI) is one important milestone of the project. The status of the demonstrator is presented.
The superconducting CH-structure (Crossbar-H-mode) is a multi-cell drift tube cavity for the low and medium energy range operated in the H21-mode, which has been developed at the Institute for Applied Physics (IAP) of Frankfurt University. With respect to different high power applications two types of superconducting CH-structures (f = 325 MHz, β = 0.16, seven cells and f = 217 MHz, β = 0.059, 15 cells) are presently under construction and accordingly under development. The structural mechanical simulation is a very important aspect of the cavity design. Furthermore, several simulations with ANSYS Workbench have been performed to predict the deformation of the cavity walls due to the cavity cool-down, pressure effects and mechanical vibrations. To readjust the fast frequency changes in consequence of the cavity shape deformation, a new concept for the dynamic frequency tuning has been investigated, including a novel type of bellow-tuner.
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
The new heavy ion superconducting continuous wave HElmholtz LInear ACcelerator (HELIAC) is under construction at GSI. A normal conducting injector, comprising an ECR ion source, an RFQ and a DTL, is recently in development. The new Interdigital H-mode DTL, presented in this paper, accelerates the heavy ion beam from 300 to 1400 keV/u, applying an Alternating Phase Focusing (APF) beam dynamics scheme. This APF section, consisting of two separately controlled tanks, has to provide for stable routine operation with assistance of dedicated beam diagnostics devices in the Intertank section. The installed quadrupole lenses and beam steerers installed there ensure full transmission in a wide range of input beam parameters.