Refine
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- CVID (1)
- European Society for Immunodeficiencies (ESID) (1)
- German PID-NET registry (1)
- Hepatitis c (1)
- IgG substitution therapy (1)
- PID prevalence (1)
- cerebrospinal fluid (1)
- contact lens solution (1)
- hepatitis C virus (1)
- infectivity (1)
Institute
- Medizin (3)
Environmental stability and infectivity of hepatitis C virus (HCV) in different human body fluids
(2018)
Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids.
Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario.
Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test.
Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.
Objective: Chronically HCV-infected orthotopic liver transplantation (OLT) recipients appear to have improved outcomes when their immunosuppressive regimen includes a mammalian target of rapamycin (mTOR) inhibitor. The mechanism underlying this observation is unknown.
Design: We used virological assays to investigate mTOR signalling on the HCV replication cycle. Furthermore, we analysed HCV RNA levels of 42 HCV-positive transplanted patients treated with an mTOR inhibitor as part of their immunosuppressive regimen.
Results: The mTOR inhibitor rapamycin was found to be a potent inhibitor for HCV RNA replication in Huh-7.5 cells as well as primary human hepatocytes. Half-maximal inhibition was observed at 0.01 µg/mL, a concentration that is in the range of serum levels seen in transplant recipients and does not affect cell proliferation. Early replication cycle steps such as cell entry and RNA translation were not affected. Knockdown of raptor, an essential component of mTORC1, but not rictor, an essential component of mTORC2, inhibited viral RNA replication. In addition, overexpression of raptor led to higher viral RNA replication, demonstrating that mTORC1, but not mTORC2, is required for HCV RNA replication. In 42 HCV-infected liver-transplanted or kidney-transplanted patients who were switched to an mTOR inhibitor, we could verify that mTOR inhibition decreased HCV RNA levels in vivo.
Conclusions: Our data identify mTORC1 as a novel HCV replication factor. These findings suggest an underlying mechanism for the observed benefits of mTOR inhibition in HCV-positive OLT recipients and potentiate further investigation of mTOR-containing regimens in HCV-positive recipients of solid organ transplants.
Introduction: The German PID-NET registry was founded in 2009, serving as the first national registry of patients with primary immunodeficiencies (PID) in Germany. It is part of the European Society for Immunodeficiencies (ESID) registry. The primary purpose of the registry is to gather data on the epidemiology, diagnostic delay, diagnosis, and treatment of PIDs.
Methods: Clinical and laboratory data was collected from 2,453 patients from 36 German PID centres in an online registry. Data was analysed with the software Stata® and Excel.
Results: The minimum prevalence of PID in Germany is 2.72 per 100,000 inhabitants. Among patients aged 1–25, there was a clear predominance of males. The median age of living patients ranged between 7 and 40 years, depending on the respective PID. Predominantly antibody disorders were the most prevalent group with 57% of all 2,453 PID patients (including 728 CVID patients). A gene defect was identified in 36% of patients. Familial cases were observed in 21% of patients. The age of onset for presenting symptoms ranged from birth to late adulthood (range 0–88 years). Presenting symptoms comprised infections (74%) and immune dysregulation (22%). Ninety-three patients were diagnosed without prior clinical symptoms. Regarding the general and clinical diagnostic delay, no PID had undergone a slight decrease within the last decade. However, both, SCID and hyper IgE- syndrome showed a substantial improvement in shortening the time between onset of symptoms and genetic diagnosis. Regarding treatment, 49% of all patients received immunoglobulin G (IgG) substitution (70%—subcutaneous; 29%—intravenous; 1%—unknown). Three-hundred patients underwent at least one hematopoietic stem cell transplantation (HSCT). Five patients had gene therapy.
Conclusion: The German PID-NET registry is a precious tool for physicians, researchers, the pharmaceutical industry, politicians, and ultimately the patients, for whom the outcomes will eventually lead to a more timely diagnosis and better treatment.