Vasointestinal peptide metabolism plays a key physiological role in multimodular levels of vasodilatory, smooth muscle cell proliferative, parenchymal, and inflammatory lung reactions. In animal studies, vasointestinal peptide relaxes isolated pulmonary arterial segments from several mammalian species in vitro and neutralizes the pulmonary vasoconstrictor effect of endothelin. In some animal models, it reduces pulmonary vascular resistance in vivo and in monocrotaline-induced pulmonary hypertension. A 58-year-old woman presented with dyspnea and mild edema of the lower extremities. A bronchoscopy was performed without any suspicious findings suggesting a central tumor or other infiltrative disease. Endobronchial ultrasound revealed enlarged pulmonary arteries containing thrombi, a few enlarged lymph nodes, and enlarged mediastinal tissue anatomy with suspicion for mediastinal infiltration of a malignant process. We estimated that less than 10% of the peripheral vascular bed of the lung was involved in direct consolidated fibrosis as demonstrated in the left upper lobe apex. Further, direct involvement of fibrosis around the main stems of the pulmonary arteries was assumed to be low from positron emission tomography and magnetic resonance imaging scans. Assuming a positive influence of low-dose radiation, it was not expected that this could have reduced pulmonary vascular resistance by over two thirds of the initial result. However; it was noted that this patient had idiopathic pulmonary arterial hypertension mixed with "acute" (mediastinal) fibrosis which could have contributed to the unexpected success of reduction of pulmonary vascular resistance. To the best of our knowledge, this is the first report of successful treatment of idiopathic pulmonary arterial hypertension, probably as a result of low-dose radiation to the pulmonary arterial main stems. The patient continues to have no specific complaints concerning her idiopathic pulmonary arterial hypertension.
Objective: To evaluate two ultrafast cone-beam CT (UF-CBCT) imaging protocols with different acquisition and injection parameters regarding image quality and required contrast media during image-guided hepatic transarterial chemoembolization (TACE).
Methods: In 80 patients (male: 46, female: 34; mean age: 56.8 years; range: 33–83) UF-CBCT was performed during TACE for intraprocedural guidance. Imaging was performed using two ultrafast CBCT acquisition protocols with different acquisition and injection parameters (imaging protocol 1: acquisition time 2.54 s, and contrast 6 mL with 3 s delay; imaging protocol 2: acquisition time 2.72 s, and contrast 7 mL with 6 s delay). Image evaluation was performed with both qualitative and quantitative methods. Contrast injection volume and dose parameters were compared using values from the literature.
Results: Imaging protocol 2 provided significantly better (P < 0.05) image quality than protocol 1 at the cost of slightly higher contrast load and patient dose. Imaging protocol 1 provided good contrast perfusion but it mostly failed to delineate the tumors (P < 0.05). On the contrary, imaging protocol 2 showed excellent enhancement of hepatic parenchyma, tumor, and feeding vessels.
Conclusion: Tumor delineation, visualization of hepatic parenchyma, and feeding vessels are clearly possible using imaging protocol 2 with ultrafast CBCT imaging. A reduction of required contrast volume and patient dose were achieved due to the ultrafast CBCT imaging.
The exact pathophysiology of contrast-induced nephropathy (CIN) is not fully clarified, yet the osmotic characteristics of contrast media (CM) have been a significant focus in many investigations of CIN. Osmotic effects of CM specific to the kidney include transient decreases in blood flow, filtration fraction, and glomerular filtration rate. Potentially significant secondary effects include an osmotically induced diuresis with a concomitant dehydrating effect. Clinical experiences that have compared the occurrence of CIN between the various classes of CM based on osmolality have suggested a much less than anticipated advantage, if any, with a lower osmolality. Recent animal experiments actually suggest that induction of a mild osmotic diuresis in association with iso-osmolar agents tends to offset potentially deleterious renal effects of high viscosity-mediated intratubular CM stagnation.
Purpose: To evaluate the effect of chronic liver disease (CLD) in a multivariate analysis of associated risk factors in patients with hepatocellular carcinoma (HCC) using transarterial chemoembolization (TACE). Materials and methods: A total of 145 patients with HCC (99 men, 46 women; mean age: 63 years ±8.1; age range: 46-84 years) underwent 598 TACE procedures. The presence of CLD, number and location of lesions, tumor size, Child-Pugh score, vascularity, portal involvement and alpha fetoprotein value were analyzed using the multivariate regression model. Cox regression was used for survival analysis. Results: The median survival time was 26.7 months, and 78.6% of all treated lesions showed tumor responses. The presence of CLD (OR 2.12, P=0.004), Child-Pugh score B (OR 2.24, P=0.002), alpha fetoprotein >100ng/dl (OR 1.18, P<0.001), multinodularity (≥3 lesions) (OR 4.41, P=0.003), lesion size >5cm (OR 4.12, P=0.002) and hypervascularity (OR 7.94, P=0.003) were significant effective factors for a local response when analyzed using a multivariate logistic model. Multivariate survival analysis using Cox's regression model during the median follow-up period of 25 months (range: 1-42 months) demonstrated a significant difference in survival rates (P values <0.05). No significant difference in responses was noted for males, locations of lesions and portal involvements statistically. Conclusion: The presence of chronic liver disease as well as associated risk factors including Child-Pugh score B, alpha fetoprotein 100ng/dl, multinodularity (≥3 lesions), lesion size >5cm and hypervascularity statistically led to a significant effect in tumor response in HCC patients treated with TACE. Patient gender, location of lesion and involvement of portal vein showed no significant difference in response.
AIM: To evaluate and compare the effect of combined transarterial chemoembolization (TACE) and arterial administration of Bletilla striata (a Chinese traditional medicine against liver tumor) versus TACE alone for the treatment of hepatocellular carcinoma (HCC) in ACI rats.
METHODS: Subcapsular implantation of a solid Morris hepatoma 3 924A (2 mm3) in the liver was carried out in 30 male ACI rats. Tumor volume (V1) was measured by magnetic resonance imaging (MRI) on day 13 after implantation. The following different agents of interventional treatment were injected after retrograde catheterization via gastroduodenal artery (on day 14), namely, (A) TACE (0.1 mg mitomycin + 0.1 ml Lipiodol) + Bletilla striata (1.0 mg) (n=10); (B) TACE + Bletilla striata (1.0 mg) + ligation of hepatic artery (n=10), (C) TACE alone (control group, n=10). Tumor volume (V2) was assessed by MRI (on day 13 after treatment) and the tumor growth ratio (V2/V1) was calculated.
RESULTS: The mean tumor volume before (V1) and after (V2) treatment was 0.0355 cm3 and 0.2248 cm3 in group A, 0.0374 cm3 and 0.0573 cm3 in group B, 0.0380 cm3 and 0.3674 cm3 in group C, respectively. The mean ratio (V2/V1) was 6.2791 in group A, 1.5324 in group B and 9.1382 in group C. Compared with the control group (group C), group B showed significant inhibition of tumor growth (P<0.01), while group A did not (P>0.05). None of the animals died during implantation or in the postoperative period.
CONCLUSION: Combination of TACE and arterial administration of Bletilla striata plus ligation of hepatic artery is more effective than TACE alone in the treatment of HCC in rats.
Background: Myocardial perfusion with cardiovascular magnetic resonance (CMR) imaging is an established diagnostic test for evaluation of myocardial ischaemia. For quantification purposes, the 16 segment American Heart Association (AHA) model poses limitations in terms of extracting relevant information on the extent/severity of ischaemia as perfusion deficits will not always fall within an individual segment, which reduces its diagnostic value, and makes an accurate assessment of outcome data or a result comparison across various studies difficult. We hypothesised that division of the myocardial segments into epi- and endocardial layers and a further circumferential subdivision, resulting in a total of 96 segments, would improve the accuracy of detecting myocardial hypoperfusion. Higher (sub-)subsegmental recording of perfusion abnormalities, which are defined relatively to the normal reference using the subsegment with the highest value, may improve the spatial encoding of myocardial blood flow, based on a single stress perfusion acquisition. Objective: A proof of concept comparison study of subsegmentation approaches based on transmural segments (16 AHA and 48 segments) vs. subdivision into epi- and endocardial (32) subsegments vs. further circumferential subdivision into 96 (sub-)subsegments for diagnostic accuracy against invasively defined obstructive coronary artery disease (CAD). Methods: Thirty patients with obstructive CAD and 20 healthy controls underwent perfusion stress CMR imaging at 3 T during maximal adenosine vasodilation and a dual bolus injection of 0.1mmol/kg gadobutrol. Using Fermi deconvolution for blood flow estimation, (sub-)subsegmental values were expressed relative to the (sub)subsegment with the highest flow. In addition, endo−/epicardial flow ratios were calculated based on 32 and 96 (sub-)subsegments. A receiver operating characteristics (ROC) curve analysis was performed to compare the diagnostic performance of discrimination between patients with CAD and healthy controls. Observer reproducibility was assessed using Bland-Altman approaches. Results: Subdivision into more and smaller segments revealed greater accuracy for #32, #48 and # 96 compared to the standard #16 approach (area under the curve (AUC): 0.937, 0.973 and 0.993 vs 0.820, p<0.05). The #96-based endo−/epicardial ratio was superior to the #32 endo−/epicardial ratio (AUC 0.979, vs. 0.932, p<0.05). Measurements for the #16 model showed marginally better reproducibility compared to #32, #48 and #96 (mean difference± standard deviation: 2.0±3.6 vs. 2.3±4.0 vs 2.5±4.4 vs. 4.1±5.6). Conclusions: Subsegmentation of the myocardium improves diagnostic accuracy and facilitates an objective cutoff-based description of hypoperfusion, and facilitates an objective description of hypoperfusion, including the extent and severity of myocardial ischaemia. Quantification based on a single (stress-only) pass reduces the overall amount of gadolinium contrast agent required and the length of the overall diagnostic study.
Microwave sensors in medical environments play a significant role due to the contact-less and non-invasive sensing mechanism to determine dielectric properties of tissue. In this work, a theranostic sensor based on Split Ring Resonators (SRRs) is presented that provides two operation modes to detect and treat tumor cells, exemplary in the liver. For the detection mode, resonance frequency changes due to abnormalities are evaluated, and in the treatment mode, microwave ablation is performed. The planar sensor structure can be integrated into a needle like a surgery tool that evokes challenges concerning size limitations and biocompatibility. To meet the size requirements and provide a reasonable operating frequency, properties of oval shaped SRRs are investigated. By elongating the radius of the SRR in one direction, the resonance frequency can be decreased significantly compared to circular SRR by a factor of two below 12 GHz. In order to validate the detection and treatment characteristics of the sensor, full wave simulations and measurements are examined. Clear resonance shifts are detected for loading the sensor structures with phantoms mimicking healthy and malignant tissue. For treatment mode evaluation, ex vivo beef liver tissue was ablated leading to a lesion zone 1.2 cm × 1 cm × 0.3 cm with a three minute exposure of maximum 2.1 W
Hemispherical and cylindrical antenna arrays are widely used in radar-based and tomography-based microwave breast imaging systems. Based on the dielectric contrast between healthy and malignant tissue, a three-dimensional image could be formed to locate the tumor. However, conventional X-ray mammography as the golden standard in breast cancer screening produces two-dimensional breast images so that a comparison between the 3D microwave image and the 2D mammogram could be difficult. In this paper, we present the design and realisation of a UWB breast imaging prototype for the frequency band from 1 to 9 GHz. We present a refined system design in light of the clinical usage by means of a planar scanning and compare microwave images with those obtained by X-ray mammography. Microwave transmission measurements were processed to create a two-dimensional image of the breast that can be compared directly with a two-dimensional mammogram. Preliminary results from a patient study are presented and discussed showing the ability of the proposed system to locate the tumor.
Background: Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems.
Purpose: To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA).
Material and Methods: CTPA scans from 60 prospectively randomized patients (28 men, 32 women) were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD) settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale.
Results: CT dose index (CTDI) in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy). Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768). Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4).
Conclusion: The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.
Simple Summary: Early and accurate diagnosis of breast cancer that has spread to other organs and tissues is crucial, as therapeutic decisions and outcome expectations might change. Computed tomography (CT) is often used to detect breast cancer’s spread, but this method has its weaknesses. The computer-assisted technique “radiomics” extracts grey-level patterns, so-called radiomic features, from medical images, which may reflect underlying biological processes. Our retrospective study therefore evaluated whether breast cancer spread can be predicted by radiomic features derived from iodine maps, an application on a new generation of CT scanners visualizing tissue blood flow. Based on 77 patients with newly diagnosed breast cancer, we found that this approach might indeed predict cancer spread to other organs/tissues. In the future, radiomics may serve as an additional tool for cancer detection and risk assessment.
Abstract: Dual-energy CT (DECT) iodine maps enable quantification of iodine concentrations as a marker for tissue vascularization. We investigated whether iodine map radiomic features derived from staging DECT enable prediction of breast cancer metastatic status, and whether textural differ- ences exist between primary breast cancers and metastases. Seventy-seven treatment-naïve patients with biopsy-proven breast cancers were included retrospectively (41 non-metastatic, 36 metastatic). Radiomic features including first-, second-, and higher-order metrics as well as shape descriptors were extracted from volumes of interest on iodine maps. Following principal component analysis, a multilayer perceptron artificial neural network (MLP-NN) was used for classification (70% of cases for training, 30% validation). Histopathology served as reference standard. MLP-NN predicted metastatic status with AUCs of up to 0.94, and accuracies of up to 92.6 in the training and 82.6 in the validation datasets. The separation of primary tumor and metastatic tissue yielded AUCs of up to 0.87, with accuracies of up to 82.8 in the training, and 85.7 in the validation dataset. DECT iodine map-based radiomic signatures may therefore predict metastatic status in breast cancer patients. In addition, microstructural differences between primary and metastatic breast cancer tissue may be reflected by differences in DECT radiomic features.