Cleaning an ion beam from unwanted fractions is crucial for intense ion beams. This thesis will explore separation methods using a collimation channel, electric and magnetic dipoles and a velocity selector for low intensity beams on an experimental basis. In addition, statistical data of degassing events during the commissioning of a pentode extraction system for beam energies from 20 - 120keV will be presented.
The aim of this thesis is finding a geometric configuration that allows electron insertion into a Gabor plasma lens in order to increase the density of the confined electrons and provide ignition conditions at parameters where ignition is not possible. First, simulations using CST and bender were conducted to investigate several geometric configurations in terms of their performance of inserting electrons manually. One particular design has been chosen as a basis for an experiment. In order to prepare the experiment, further simulations using the code bender have been conducted to investigate the density distribution that is formed inside the Gabor lens when inserting electrons transversally in compliance with the chosen design. Additionally, bender was used to investigate the impact of the initial electron energy on the distribution inside the lens. Simulations with and without space charge effects have shown a significant impact of the space charge effects on the resulting density dstribution. Therefore, space charge effects have proven to be the major electron redistribution process. A given electron source was characterised in order to find the performance under the conditions inside a Gabor lens. In particular, a transversal magnetic field that will be present in the experiment has to be compensated by shielding the inner regions of the source by a μ-metal layer. Using a μ-metal shield, transversal magnetic fields are sufficiently tolerable to perform measurements in a Gabor lens. Additionally, operating close to 100 eV electron energy yields a maximum in the emitted current. Adding a Wehnelt cylinder to the electron source furthermore improves the extracted current to roughly 1 mA. A test stand consisting of a newly designed anode for the Gabor lens, as well as a terminal for the electron source, was constructed. The electron source was thoroughly characterised in the environment of the Gabor lens and the ignition properties of the new system were evaluated. In further experiments, electron beam assisted ignition by increasing the residual gas pressure was observed and the impact of the position of the electron source on the ignition properties was investigated. In addition, ignition of a sub-critical state, that is a state consisting of potential, magnetic field and pressure that did not yet perform ignition by itself, was performed by increasing the extracted current from the electron source. Finally, the electron source was used to influence a pre-ignited plasma. The density was measured, which was increased by the use of the electron source in most cases. This project is part of the EDEN collaboration (Electron DENsity boosting) of the NNP Group at IAP Frankfurt with INFN institutes in Bologna and Catania.
Zur effizienten Beschleunigung von Ionen wird meist nach deren Erzeugung in einer Ionenquelle ein Radio Frequenz Quadrupol verwendet. Die vorliegende Dissertation befasst sich mit Entwicklung, Bau und Messung des Prototyps eines neuartigen Leiter-RFQs, der bei 325 MHz betrieben wird. Der Leiter-RFQ verfügt über ein neuartiges mechanisches Design und versucht die Vorteile der beiden vorrangig im Betrieb befindlichen RFQ Typen, des 4-Rod und 4-Vane RFQs, zu verbinden. Die physikalischen Parameter sind der Spezifikation des RFQs für den geplanten Protonenlinac (p-Linac) am FAIR-Projekt an der GSI Darmstadt entnommen. Darüber hinaus wird der aktuelle Planungs- und Simulationsstand eines modulierten Prototyps mit der vollen Länge von ca. 3,5 m zur Durchführung von Strahltests dargestellt.
This dissertation presents the development of a new radio frequency quadrupole (RFQ) structure of the 4-rod type with an operating frequency of 108 MHz for the acceleration of heavy ions with mass-to-charge ratios of up to 8.5 at high duty cycles up to CW operation ("continuous wave") at the High Charge Injector (HLI) of the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt.
The need to develop a completely new RFQ for the HLI arises from the fact that with the previously designed and built 4-rod RFQ structure, which was commissioned at the HLI in 2010 as part of the planned HLI upgrade program, the desired operating modes in both pulsed and CW operation could not be achieved even after several years of operating experience and considerable efforts to eliminate or at least mitigate the severe operational instabilities. Mechanical vibrations of the electrodes, which result in strong modulated power reflection, as well as the high thermal sensitivity proved to be particularly problematic.
In addition to the RF design of the new RFQ by simulations performed with the CST Microwave Studio software, the focus of the investigations fell on the mechanical analysis of vibrations on the electrode rods caused by RF operation, for which the ANSYS Workbench software was used. Due to the high thermal load of the RFQ structure of more than 30 kW/m in CW operation, an accurate analysis of the thermal effects on electrode deformation as well as resulting frequency detuning of the resonator is also required, which was investigated by simulations within the capabilities of CST Mphysics Studio.
Based on the results of the design studies carried out by simulations and the thereby achieved design optimizations, a 4-rod RFQ prototype with 6 stems was finally manufactured, on which most of the properties expected from the simulations could be validated by measurements of the RF characteristics as well as of the vibration behavior.
Finally, based on the results of the pre-tests and considering a newly developed beam dynamics concept, a completely revised RF design for a new full-length HLI-RFQ was derived from the prototype design.
The first part of this work addresses the automatic online tuning of transfer lines in particle accelerator facilities. In the second part the focus lies on the automatic construction and optimisation of such transport lines. It can be shown that genetic algorithms can be used very well for optimisation in both cases. Automatic online tuning can be performed very efficiently at accelerators under certain boundary conditions and is particularly well suited for initial beam commissioning with low intensity pilot beams. The construction of transfer lines can also be formulated and solved as an minimisation problem with an adopted parameterisation. Thereby, both the imaging properties of the beam transport and the robustness against error studies can be optimised at the same time.
Der Radiofrequenzquadrupol (RFQ) wird typischerweise als erstes beschleunigendes Element in Beschleunigeranlagen eingesetzt. Das elektrische Quadrupolfeld ermöglicht die gleichzeitige Fokussierung und Beschleunigung des Ionenstrahls. Zudem ist der RFQ in der Lage den Gleichstromstrahl von der Ionenquelle zu Teilchenpaketen (Bunche) zu formen, die von den nachfolgenden Driftröhrenbeschleunigern benötigt werden. Ziel der vorliegenden Arbeit war die Untersuchung zur Realisierbarkeit eines 325 MHz 4-rod RFQ Beschleunigers. Die Frequenz von 325 MHz stellt eine ungewöhnlich hohe Betriebsfrequenz für die 4-rod Struktur dar und wird z.B. für den Protonenlinac des FAIR Projektes benötigt. Ein Problem hierbei war, dass durch die bauartbedingten unsymmetrischen Elektrodenaufhängung und der hohen Frequenz ein, das Quadrupolfeld überlagerndes, Dipolfeld erzeugt wird. Dieses störende Feld kann z.B. zu einem Versatz der Strahlachse führen. Hierzu wurde die 4-rod Struktur in Simulationen grundlegend auf Einflüsse von verschiedenen Parametern auf die Resonanzfrequenz und das Dipolfeld untersucht. Es wurden Lösungsstrategien erarbeitet das Diopolfeld zu kompensieren und auf einen Prototypen angewendet. Zudem wurde das Verhalten höherer Schwingungsmoden dieser Struktur simuliert. In diesem Rahmen wurden auch Simulationen zu Randfeldern zwischen den 4-rod Elektroden und der Tankwand untersucht, um nachteilige Effekte für die Strahlqualität auszuschließen. Basierend auf den Simulationsergebnissen wurde ein Prototyp angefertigt. Dieser Prototyp wurde zur Demonstration der Betriebseigenschaften mit Leistungen bis 40 kW getestet. Hierbei wurde die Elektrodenspannung mittels Gammaspektroskopie bestimmt und daraus die Shuntimpedanz berechnet. Diese Werte wurden mit anderen Methoden der Shuntimpedanzbes- timmung verglichen. Außerdem wurden alternative RFQ Resonatorkonzepte ebenfalls auf ihre Realisierbarkeit für den Protonenlinac untersucht. Die Einflüsse verschiedener Parameter auf die Betriebsfrequenz, die Möglichkeiten des Frequenztunings und der Einstellung der longitudinalen Spannungsverteilung gefertigter Modelle wurden in einer Diskussion gegenübergestellt.
Precise intensity monitoring at CRYRING@ESR: on designing a Cryogenic Current Comparator for FAIR
(2023)
In the field of today’s beam intensity diagnostic there is a significant gap in the non-interceptive, calibrated measurement of the absolute intensity of continuous (unbunched) dc beams with current amplitudes below 1 μA. At the Facility for Antiproton and Ion Research (FAIR) low-intensity DC beams will occur during slow extraction from the synchrotrons as well as for coasting beams of highly-charged or exotic nuclei in the storage rings. The lack of adequate beam instrumentation limits the experimental program as well as the accuracy of experimental results.
The Cryogenic Current Comparator (CCC) can close the diagnostic gap with a high-precision dc current reading independent of ion-species and of beam parameters. However, the established detector design based on a core with high magnetic permeability and on a radial shield geometry has well-known weaknesses concerning magnetic shielding efficiency and intrinsic current noise. To eliminate these weaknesses, a novel coreless CCC with a co-axial shield was constructed and combined with a high-performance SQUID contributed by the Leibniz-Institute of Photonic Technology (Leibniz-IPHT Jena). The new axial CCC model was compared to a radial CCC with the established design provided by the Friedrich-Schiller-University Jena. According to numerical simulations prepared at TU Darmstadt and test measurements of the detectors in the laboratory, the new design offered a significant improvement of the shielding factor – from 75dB to 207dB at the required dimensions – and eliminated all noise contributions from the core material, promising an improved current resolution. Although the lower inductance of the pickup coil reduced the coupling to the beam significantly, the noise properties of the new CCC type were comparable to the classical version with a high-permeability core. However, the expected decrease of the low-frequency noise and thus an increase of the current resolution could not be observed at this stage of development.
Consequently, the classical CCC based on the radial shielding and high-permeability core had to be installed in CRYRING@ESR to provide best possible intensity measurements for the upcoming experimental campaign. In CRYRING the CCC was operated with beam currents between 1nA and 20μA and with different ion species (H, Ne, O, Pb, U). It was shown that the CCC provides a noise-limited current resolution of better than 3.2 nArms at a bandwidth of 200 kHz as well as a noise level below 40 pA/√Hz above 1 kHz. During the operation, the main noise sources of the accelerator environment had to be identified and suitable mitigation strategies were developed. Temperature and pressure fluctuations were suppressed with a newly-designed cryogenic support system based on a 70 l helium bath cryostat, developed and built in collaboration with the Institut für Luft- und Kältetechnik Dresden, in combination with a helium re-liquefier. The cryogenic operating time was restricted to around 7 days, which must be expanded significantly in the future. Digital filters were developed to remove the perturbations of the helium liquefier and of the neighboring dipole magnets. Given the promising results the CCC system can be considered as a prototype for future CCCs at FAIR.
As part of the research for this thesis, a momentum spectrometer was set up and initial measurements on accelerated ions were performed. For this purpose, the necessary hardware for the operation of the spectrometer and for high-precision measurements was were assembled. A control system for remote operation was developed and the spectrometer was installed at the used beamline.
There, measurements of low-energy ion beams in superposition with electrons confined in a Gabor lens can be carried out.
Investigations were made on both the Gabor lens-generated ions and the beam ions, leading to first results regarding the charge changes of beam ions during propagation through an electron atmosphere.
This thesis discusses important questions of the beam dynamics in the proton-lead operation in the Large Hadron Collider (LHC) at CERN in Geneva. In two time blocks of several weeks in the years 2013 and 2016, proton-lead collisions have so far been successfully generated in the LHC and used by the experiments at the LHC. One reason for doubts regarding the successful operation in proton-lead configuration was the fact that the beams have to be accelerated with different revolution frequencies. There is long-range repulsion between the beams, since both beams share the beam chamber around the interaction points. Because of the different revolution frequencies, the positions of the interaction between the beams shift each revolution. This can lead to resonant excitation and to an increase in the transverse beam emittance, as was observed in the Relativistic Heavy-Ion Collider (RHIC). In this thesis, simulations for the LHC, RHIC and the High-Luminosity Large Hadron Collider (HL-LHC) are performed with a new model. The results for RHIC show relative growth rates of the emittances of the gold beam in gold-deuteron operation in RHIC from 0.1 %/s to 1.5 %/s. Growth rates of this magnitude were observed experimentally in RHIC. Simulations for the LHC show no significant increase of the emittance of the lead beam for different intensities of the counter-rotating beam. The simulation results confirm the measured stability of the beams in the LHC and the issue of strongly increasing emittances in RHIC is reproduced. Also, no significant increase of the emittance is predicted for the Future Circular Collider (FCC) and the HL-LHC.
Using a frequency-map analysis, this work verifies whether the interaction of the lead beam with the much smaller proton beam in the proton-lead operation of the LHC leads to diffusion within the lead beam. Experiences at HERA at DESY in Hamburg and at SppS at CERN have shown that the lifetime of the larger beam can rapidly decrease under certain circumstances. The results of the simulation show no chaotic dynamics near the beam centre of the lead beam. This result is supported by experimental observation.
A program code has been developed which calculates the beam evolution in the LHC by means of coupled differential equations. This study shows that the growth rates of the lead beam due to intra-beam scattering is overestimated and that particle bunches of the lead beam lose more intensity than assumed in the model. The analysis also shows that bunches colliding in a detector suffer additional losses that increase with decreasing crossing angle at the interaction point.
In this work, 2016 data from beam-loss monitors in combination with the luminosity and the loss rate of the beam intensity are used to determine the cross section of proton-lead collisions at the center-of-mass energy of 8.16 TeV. Beam-loss monitors that mainly detect beam losses that are not caused by the collision process itself are used to determine the total cross section via regression. An analysis of the data recorded in 2016 at the center-of-mass energy of 8.16 TeV resulted in a total cross section of σ=(2.32±0.01(stat.)±0.20(sys.)) b. This corresponds approximately to a hadronic cross section of σ(had)=(2.24±0.01(stat.)±0.21(sys.)) b. This value deviates only by 5.7 % from the theoretical value σ(had)=(2.12±0.01) b.
The simulation code for determining the beam evolution is also used to estimate the integrated luminosity of a future one-month run with proton-lead collisions. The result of the study shows that in the future the luminosity in the ATLAS and CMS experiments will increase from 15/nb per day in 2016 to 30/nb per day, which is a significant increase in terms of the performance. This operation, however, requires the use of the TCL collimators to protect the dispersion suppressors at ATLAS and CMS from collision fragments.
This work also gives an outlook on the expected luminosity production in proton-nucleus operation using ion species lighter than lead ions. For example, a change from proton-lead to proton-argon collisions would increase the integrated luminosity from monthly 0.8/nb to 9.4/nb in ATLAS and CMS. This is an increase of one order of magnitude and approximately a doubling of the integrated nucleon-nucleon luminosity. There may be a test operation with proton-oxygen collisions in 2023, which will last only a few days and will be operated with a low luminosity. The LHCf experiment (LHCb experiment) would achieve the desired integrated luminosity of 1.5/nb (2/nb) within 70h (35h) beam time.
The development of the designs of the superconducting CH cavities of the HELIAC project from CH0 [27] to CH1 and CH2 [1] has undergone permanent improvements and adaptations based on the learned experiences of each previous cavity. For example, the design of CH1 and CH2 focused on mechanical stabilization and optimization of performance by minimizing peak electric and magnetic fields. As a result, the changes made there were already able to increase stability and performance compared to CH0 by simplifying the design in different ways. The process of designing both cavities was time reasonable, since they are identical in construction and thus only one design had to be developed. However, for both the development and manufacturing of an entire accelerator of individual CH cavities, this type of design would become too time consuming and costly. In order to reduce this time-consuming design process and accelerate the fabrication of superconducting CH cavities, and also reduce costs, a modular cavity design for mass production of superconducting CH cavities was developed as presented in this thesis. In the following section, the conclusions gained in this work and the results already presented will be summarized once again.
So in the first chapters of this thesis the theoretical foundations were laid, which are necessary for the description of superconducting cavities and for their development process, like a theoretical description of superconductivity itself (see chapter 2), the physical basics of RF-acceleration and of the CH cavity (see chapter 3), but also the effects that limit the superconducting cavities in terms of acceleration (see chapter 4) or the properties and laws from structural mechanics needed in later measurements and simulation (see chapter 5). Based on the theoretical foundations given in these sections, all measurements, evaluations and simulations made in the following sections were made.