Refine
Year of publication
- 2010 (1)
Document Type
- Doctoral Thesis (1)
Language
- English (1) (remove)
Has Fulltext
- yes (1)
Is part of the Bibliography
- no (1)
Institute
- Medizin (1)
Clinical application of transcranial Doppler for detection of cerebral emboli during cardiac surgery
(2010)
Objective: Neurologic injury is one of the most damaging complications for cardiac surgery. How to decrease neurologic impairment by improving perioperative monitoring remains a challenge for both cardiac surgeons and anesthetists. For this reason, transcranial doppler (TCD) has been widely used in cerebral monitoring during cardiac surgery. In this study, two experiments of clinical application of TCD for detection of cerebral emboli during cardiac surgery were to be done. One was “Solid and gaseous cerebral emboli during valvular surgery are significantly reduced with axillary artery cannulation”. The other was “Do intraoperative cerebral embolic signals differ between valvular surgery (VS) and CABG”. Methods: In experiment one, 20 valve and combined procedures with aortic cannulation (AoC group) were compared to 18 procedures with axillary cannulation (AxC group) in a prospective non-randomized study. In experiment two, 18 VS patients and 18 CABG patients were matched by extracorporeal circulation (ECC) time retrospectively. Intraoperative monitoring of both middle cerebral arteries was performed with TCD discriminating between solid and gaseous embolic signals (ES). Results: In experiment one, the AxC group had less solid ES than the AoC group (38±22 vs 55±25, P<0.05), but no significant difference was found in gaseous (501±271 vs 538±333, P>0.05) and total (539 ± 279 vs 593 ± 350, P>0.05) ES. The AxC group had less solid ES during arterial cannulation (2.1±1.5 vs 6.6±3.6, P<0.05) and during aortic cross-clamp time (4.4 ±3.1 vs 10.2 ± 5.1, P<0.05) than the AoC group. During ECC, gaseous ES was not significantly different between groups (398±210 vs 448±291, P>0.05). However, AxC showed less gaseous ES (85±68 vs 187±148, P<0.05) and less gaseous ES per minute (1.8±1.5 vs 4.5±3.2, P<0.05) during weaning off extracorporeal circulation than the AoC group. No significant difference in gaseous ES (313±163 vs 261±189, P>0.05) and gaseous ES per minute (3.1±2.2 vs 2.8±2.2, P>0.05) was found between groups from bypass start to aortic declamping. No neurologic complications occurred. In experiment two, no significant difference was found in solid (38±20 vs 40±26, P>0.05) or gaseous (457±263 vs 412±157, P>0.05) ES between the VS and CABG group during the whole recording time. During ECC, solid ES (20±10 vs 24±19, P>0.05) and gaseous ES (368±230 vs 317±157, P>0.05) were comparable between groups. Specifically, during weaning off ECC, the VS group had more gaseous ES/min (5.6±3.6 vs 3.1±1.2, P<0.05) than the CABG group. But this difference in gaseous ES/min was not significant during the period from bypass start to aortic declamping (2.5±1.8 vs 3.0±1.8, P>0.05). Conclusion: Cerebral embolization does occur during cardiac surgery. Through these two experiments, we demonstrated the feasibility and importance of clinical application of transcranial doppler for detection of cerebral emboli during cardiac surgery. Due to the diversity in clinical application of TCD, it is impossible to compare the number of ES between different research centers. More unified standards should be drawn in order to make wider clinical application possible. Up till now, no robust evidence shows the correlation between intraoperative ES and postoperative neurological impairment. The research on intraoperative ES and postoperative neurological impairment should rely on a complete concept.