Refine
Year of publication
- 2008 (21) (remove)
Document Type
- Doctoral Thesis (21) (remove)
Has Fulltext
- yes (21)
Is part of the Bibliography
- no (21)
Keywords
- Spektroskopie (3)
- ALICE <Teilchendetektor> (2)
- CERN (2)
- Datenanalyse (2)
- Elementarteilchen (2)
- Kernphysik (2)
- LHC (2)
- Quark-Gluon-Plasma (2)
- Schwerionenkollisionen (2)
- Schwerionenphysik (2)
Institute
- Physik (21) (remove)
In this work we study the non-equilibrium dynamics of a quark-gluon plasma, as created in heavy-ion collisions. We investigate how big of a role plasma instabilities can play in the isotropization and equilibration of a quark-gluon plasma. In particular, we determine, among other things, how much collisions between the particles can reduce the growth rate of unstable modes. This is done both in a model calculation using the hard-loop approximation, as well as in a real-time lattice simulation combining both classical Yang-Mills-fields as well as inter-particle collisions. The new extended version of the simulation is also used to investigate jet transport in isotropic media, leading to a cutoff-independent result for the transport coefficient $hat{q}$. The precise determination of such transport coefficients is essential, since they can provide important information about the medium created in heavy-ion collisions. In anisotropic media, the effect of instabilities on jet transport is studied, leading to a possible explanation for the experimental observation that high-energy jets traversing the plasma perpendicular to the beam axis experience much stronger broadening in rapidity than in azimuth. The investigation of collective modes in the hard-loop limit is extended to fermionic modes, which are shown to be all stable. Finally, we study the possibility of using high energy photon production as a tool to experimentally determine the anisotropy of the created system. Knowledge of the degree of local momentum-space anisotropy reached in a heavy-ion collision is essential for the study of instabilities and their role for isotropization and thermalization, because their growth rate depends strongly on the anisotropy.
Die Analyse der Ionisation des in Zürich durchgeführten Ionisationsexperimentes an Helium hat in erster Line gezeigt, wie exakt die optischen Eigenschaften der lambda/4 Platte bekannt sein müssen, um die richtigen Schlussfolgerungen aus den experimentellen Daten zu ziehen. Insbesondere, dass bei der Bandbreite des verwendeten Lichtes, rein zirkulare Laserpulse mit den heutzutage zu Verfügung stehenden Verzögerungsplatten nicht erzeugt werden können und wie gravierend sich eine Restelliptizität von wenigen Prozent auf die Impulsverteilung auswirkt. Wird dieses Wissen jedoch in die Analyse mit eingebracht, so erlaubt der präsentierte Ansatz eine Bestimmung des Ionisationszeitpunktes mit der Genauigkeit in der Größenordnung von 10 Prozent der Dauer einer Laserperiode. Diese Analyse erlaubt in Zukunft in Experimenten mit zirkular polarisierter Laserstrahlung beim Auftreten von Mehrfachionisation die Bestimmung der Zeitintervalle zwischen den einzelnen Ionisatiosereignissen. Des weiteren ermöglicht die vorgestellte Analyse aus den gemessenen Impulsvereilungen eine CEO-Phasenbeestimmung durzuführen, bei welcher die Anzahl der benötigten Ionisationsvorgänge geringer ist als bei der Benutzung eines Stereo-ATI. In Verbindung mit Detektorsystemen, welche in der Lage sind die Winkelverteilungen für Ereignisse zu bestimmen, bei denen sehr viele Ionisationsereignisse auf einmal auftreten, kann die Anzahl der Laserschüsse, die für die Bestimmung der CEO-Phase benötigt werden, stark verringert werden. Das Pump-and-Probe-Experiment liefert trotz der Problematik, welche sich in diesem Fall bei der Anwendung des Pump-and-Probe-Schemas auf Grund der zur Verfügung stehenden Wellenlänge ergeben einen Hinweis auf die Zeitdauer, die zur Isomerisation benötigt wird. Bei den gewählten Intensitäten ist nach einem Zeitraum zwischen 30 und 60 fs zwischen dem Pump- und Probe-Puls ein Anstieg der Anzahl der in drei Teilchen fragmentierten Moleküle zu beobachten, welche einer Vinylidenkonfiguration entstammen. Der relative Anstieg der Vinylidenpopulation beträgt zehn Prozent. Der Grund, dass kein Anstieg der Vinyliden Population von null an zu beobachten ist, ist wahrscheinlich dadurch begründet, dass die Isomerisation schon an den Flanken des Pump-Pulses stattfindet und schon vor Erreichen der maximalen Intensität des Pump-Pulses abgeschlossen ist. Der Analoge Prozess könnte an den Flanken des Probe-Pulses stattfinden. Dies muss durch eine separate theoretische Behandlung erörtert werden.
The production of quarkonia, the bound state of an heavy quark with its anti-particle, has for a long time been seen as a key process to understand the properties of nuclear matter in a relativistic heavy-ion collision. This thesis presents studies on the production of quarkonia in heavy-ion collisions at the new Large Hadron collider (LHC). The focus is set on the decay of J/Psi and Upsilon-states into their di-electronic decay channel, measured within the central detectors of the ALICE detector.
In the field of strongly correlated electron systems, there is a long standing discussion on whether lattice degrees of freedom play a role for several physical phenomena, among them the Mott MI transition and charge-ordering transition. Charge-transfer salts of the ..-(BEDT-TTF)2X and (TMTCF)2X families have been revealed as model systemss for the study of the latter phenomena. The (TMTCF)2X salts have been recognized as model systems for studying correlation effects in 1D, while the (BEDT-TTF)-based materials for such studies in 2D. In this work, high-resolution dilatometry experiments were performed in order to address these issues. The main results obtained are summarized below. ...
Motiviert durch aktuelle atomphysikalische Fragestellungen zur Struktur und Dynamik der Materie im Bereich hochgeladener Schwerionen entstand der Bedarf zur Weiterentwicklung bestehender und zur Entwicklung neuartiger ortsauflösender Detektorsysteme. Die Untersuchung der Struktur ist hauptsächlich durch die hochauflösende spektroskopische Vermessung einzelner Energieniveaus der atomaren Hülle bestimmt und liefert grundlegende Einblicke in den atomaren Aufbau. Dabei stellen diese Resultate gerade bei schweren hochgeladenen Ionen eine exzellente Testmöglichkeit der QED in extrem starken Feldern dar. Die Dynamik der Materie zeigt sich in der Teilchendynamik (hier der Atomhülle) in extrem starken und extrem kurzen elektromagnetischen Feldern, wie sie bei Ion-Atom-Stößen auftreten. Beobachtet werden können hier vor allem Teilchen und Photonen-Polarisationsphänomene. Solche Polarisationseffekte sind jedoch nicht auf das Gebiet der atomaren Hülle beschränkt. Als ein Beispiel sei die Untersuchung laserbeschleunigter Teilchen genannt. Hier kann die Polarimetrie von Röntgenstrahlung, die durch Thomson-Streuung optischer Photonen an den zuvor auf relativistische Geschwindigkeiten beschleunigten Teilchen erzeugt wird, Aufschluß über die Natur des Beschleunigungsprozesses geben. Einblick in die lineare Polarisation der Röntgenphotonen im für unsere Arbeit interessanten Energiebereich von einigen 10 keV bis einigen 100 keV können mit Compton-Polarimetern gewonnen werden. Kommerziell sind Detektorsysteme, die eine ausreichende Granularität in Kombination mit hinreichender Detektordicke besitzen, um hohe Nachweiseffizienzen zu erreichen, jedoch nicht verfügbar. Im Rahmen der vorgelegten Arbeit, die sich mit Techniken der hochaufgelösten Röntgenspektroskopie und der Röntgenpolarimetrie an hochgeladenen Schwerionen befasst, wurden vielfältige Arbeiten an und mit orts-, zeit- und energieauflösenden planaren Ge(i)-Detektorsystemen durchgeführt. Wesentliches Ziel der Arbeit war es, ein zweidimensional ortsauflösendes planares Halbleiterdetektorsystem, das für den Einsatz im Kristallspektrometer FOCAL und als Compton-Polarimeter angepasst ist, bereitzustellen. Hierzu wurde ein 2D-µ-Streifendetektorsystem aufgebaut, das eine Ortsauflösung von 250µm, bzw. 1167µm in orthogonaler Richtung, bei einer Detektordicke von 11mm und eine Energieauflösung von etwa 2 keV für jeden einzelnen Streifen bei 60 keV Photonenenergie gewährleistet. Durch Messungen an der Synchrotronquelle ESRF, Grenoble (Frankreich), wurde die Eignung des Systems als bildgebendes Element im FOCAL Kristallspektrometer bei einer Photonenenergie von 60 keV und als Compton-Polarimeter bei einer Photonenenergie von 210 keV untersucht. Der große Vorteil in FOCAL ein ortsauflösendes Detektorsystem einzusetzen, liegt darin, dass alle interessanten Beugungswinkel simultan beobachtet werden können. Im herkömmlichen Ansatz würde man mit einer einfachen Diode und einem Kollimator den Bereich abfahren. Wegen der geringen Ereignisrate und dem hohen Untergrund ist dies jedoch nicht praktikabel. Herkömmliche Systeme wie CCD oder Gasdetektoren haben nicht die nötige Effizienz oder eine zu hohe Dunkelrate. Zur Untersuchung der für FOCAL wichtigen Eigenschaften wurden mehrere Positionen auf dem Detektor bei niedriger Energie mit einem fein kollimierten Photonenstrahl (50 x 50 µm2) gescannt. Neben der guten Energieauflösung des Detektorsystems von durchschnittlich 2.2 keV bei 60 keV, zeigen die Ergebnisse das homogene Verhalten der Detektoreffizienz, welche essentiell für den spektographischen Einsatz in FOCAL ist. Es konnten keine Hinweise auf messbare Ladungsverluste im Bereich des aktiven Detektorvolumens festgestellt werden. Ebenso konnte die Multiplizität (Anzahl der Streifen einer Detektorseite, die auf ein Ereignis reagieren), mit der ein Photon nachgewiesen wird, eindeutig mit der Strukturierung der Kontakte auf der Kristalloberfläche in Verbindung gebracht werden. Es stellte sich heraus, dass die Ereignisse der Multiplizität zwei dazu verwendet werden können um Ortsauflösungen deutlich unterhalb einer Streifenbreite zu erreichen. Diese Methode kann jedoch nur auf eine größere Anzahl von Ereignissen angewendet werden, nicht jedoch auf einzelne Ereignisse. Um das 2D-Ge(i)-µ-Streifendetektorsystem auf seine Eignung als Compton-Polarimeter zu testen, wurden Daten mit einem nahezu vollständig linear polarisierten Photonenstrahl (98% linear polarisiert) bei einer Energie von 210 keV aufgenommen. Die Daten zeigen die erwartete Dipol-ähnliche Asymmetrie im Ortsbild und dienen als Kalibrationsgrundlage zur Interpretation zukünftiger Experimente zur Polarimetrie in diesem Energiebereich. Parallel hierzu wurde an Simulationsprogrammen auf Basis der etablierten Monte Carlo Software EGS4 gearbeitet. Hiermit wurden Vorhersagen bezüglich des Nachweisverhaltens des Detektors auf linear polarisierte Röntgenstahlung gemacht. Ferner wurde für ein 4x4-Pixel-Polarimeter, das bei der ersten Bestimmung der linearen Polarisation der K-REC Strahlung von U92+ am Speichering ESR der GSI eingesetzt wurde, im Rahmen der Datenanalyse mit den auf EGS4-basierenden Programmen die Detektoreffizienz für linear polarisierte Strahlung einer bestimmten Energie simuliert. Mit diesen Simulationsergebnissen konnten die selbstentwickelten Methoden zur Korrektur der Nachweiswahrscheinlichkeit eines Compton-Ereignisses als Funktion des Wechselwirkungspunkts innerhalb des Detektorkristalls und der Energie erfolgreich verifiziert werden. Die detektorbezogenen Resultate dieser Arbeit fanden ihre erste Anwendung in der FOCAL-Spektrometer Strahlzeit 2006, deren genaue Beschreibung jedoch über den Umfang dieser Arbeit hinausgeht. Ebenso flossen die Erfahrungen, die mit den Detektorsystemen, im speziellen dem 2D-Ge(i)-µ-Streifendetektor, gemacht wurden in die Realisierung eines Si(Li)-Detektors mit 32+32 Streifen zur Compton-Polarimetrie bei niedrigeren Energien (ab 60 keV) ein, der gegenwärtig in ersten Experimenten am ESR eingesetzt wird.
Electron tomography was used to investigate membrane proteins in a variety of contexts. A high-angle tilt holder, suitable for electron tomography was designed, constructed and characterised. 2D crystals of membrane proteins, NhaA and YidC, were examined as a resolution test, and a method established for determining planarity of crystals. A model for specific gold binding to NhaA crystals was also presented. ATP synthase, a membrane protein complex in mitochondria, were imaged in a frozen hydrated state. They were found to form ribbons of dimers at highly curved regions of the membrane. Dimers from bovine heart and rat liver were excised from the tomographic volumes and averaged. Based on the location of the dimers in the mitochondrion, a model was established whereby ATP synthase, a molecular motor driven by the proton motive force, benefits from the high curvature that it induces in the membrane. Whole yeast mitochondria, imaged by electron cryo-tomography, also contained long ribbons of dimeric ATP synthase. Multiple copies of an unknown membrane protein complex were visualised by electron cryo-tomography, excised and averaged. A general method for the identification of unknown proteins was presented to deal with this inevitable issue, as native tissues and organelles are imaged, and the structures of complexes determined in situ.
A novel experimental approach for studying exotic transitions in few-electron high-Z ions was developed. In this approach, few-electron ions with selectively produced single K-shell holes are used for the investigation of the transition modes that follow the decay of the excited ions. The feasibility of the developed approach was confirmed by an experimental study of the production of low-lying excited states in He-like uranium, produced by K-shell ionization of initially Li-like species. It was found that K-shell ionization is a very selective process that leads to the production of only two excited states, namely the 1s2s 21S0 and 1s2s 23S1. This high level of selectivity stays undisturbed by the rearrangement processes. These experimental findings can be explained using perturbation theory and an independent-particle model, and are a result of the very different impact parameter dependencies of K-shell ionization and L- intrashell excitation. The L-shell electron can be assumed to stay passive in the collision, whereas the K-shell electron is ionized. It was stressed that the current result might directly be applied to accurate studies of the two-photon decay in He-like ions. Up to now, the experimental challenge in conventional 2E1 experiments has been the photon-photon coincidence technique, which is required to separate the true 2E1 events from the x-ray background associated with single photon transitions. In contrast, by exploiting K-shell ionization, the spectral distribution of the two-photon decay could be obtained simply by a measurement of the photon emission, using only a single x-ray detector in coincidence with projectile ionization. One further particular advantage arises from the fact that the 1s2p 3P0 state is not populated, and does not contribute to the continuum distribution of the two-photon emission. At high Z, this state also undergoes a two-photon E1M1 decay, which would be indistinguishable from the 2E1 decay of the 1s2s 1S0. The first measurement of the two-photon energy distribution from the decay of 1s2s 1S0 level in He-like tin was performed by adopting the technique developed in this thesis. In this technique, excited He-like heavy ions were formed by K-shell ionization of initially Li-like species in collisions with a low-Z gas target, and x-ray spectra following the decay of the He-like ions were measured in coincidence with the up-charged tin ions. The observed intense production of the 2E1 transitions, and a very high level of selectivity, make this process particularly suited for the study of the two-photon continuum, and thus for a detailed investigation of the structure of high-Z He-like systems. The method allowed for a background-free measurement of the distribution of the two-photon decay (21S0 -> 11S0) in He-like tin. The measured distribution could also be discriminated from that of other He-like ions, and confirmed, for the first time, the fully relativistic calculations. In addition, the feasibility of the method was confirmed by studying another exotic transition, namely the two-electron one-photon transition (TEOP) in Li-like high-Z ions. An experimental investigation of the radiative decay modes of the 1s2s2 state in Li-like heavy ions has been started. In the first dedicated beam time at the ESR, selective population of this state via K-shell ionization of initially Be-like species was achieved. The x-rays produced in this process were measured by a multitude of x-ray detectors, each placed under different observation angles with respect to the ion beam direction. The spectra associated with projectile electron loss consist (in all cases) of one single x-ray transition, which was attributed to the TEOP decay to the 1s2 2p1/2 level, possibly contaminated by the M1 decay to the 1s22s. Thus it was proven that, by adopting the developed approach, one can indeed produce the desired initial state. This makes this method perfectly suited for studies of TEOP transitions in high-Z systems. An extension of this study, by the inclusion of an electron spectrometer, would also allow for measurements of the autoionization channel, which would provide complete information on the various decay modes of the 1s2s2 state.
ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.
Gegenstand dieser Arbeit ist die Entwicklung, der Aufbau und die Charakterisierung sowie Messung einer anwendungsspezifischen integrierten Schaltung (engl.: Application Specific Integrated Circuit, ASIC). Sie dient der Auslese der im elektromagnetischen Kalorimeter des PANDA-Experiments eingesetzten Lawinenfotodioden. Jeder Auslesekanal beinhaltet in der Eingangsstufe einen ladungsempfindlichen Vorverstärker, gefolgt von einem Pulsformer sowie zwei Ausgangstreibern. Am Beginn der Entwicklung steht die Machbarkeitsstudie einer integrierten Ausleseelektronik, welche die anspruchsvollen Anforderungen des PANDA-Experiments erfüllt. Aus rauschtheoretischen Untersuchungen resultieren erste Entwurfsparameter für die Schaltung, die mit Hilfe umfangreicher Simulationen verbessert und ergänzt werden. Die technische Umsetzung der Schaltung erfolgt in einem 0,35 Micrometer-CMOS-Prozess der Firma Austria Mikrosysteme. Die Charakterisierung der integrierten Ausleseelektronik ergibt bei einer Umgebungstemperatur von T = - 20° C eine Shapingzeit des Signalpulses von tr = (124 ± 2) ns. Mit dem äquivalenten Rauschwert von ENC = (4456 ± 35) e- und einer maximal möglichen Eingangsladung von 7,84 pC folgt ein dynamischer Bereich von über 10 000. Der ratenunabhängige Leistungsbedarf eines einzelnen Auslesekanals beträgt P = (52, 4 ± 0, 2)mW. Damit erfüllt der in dieser Arbeit beschriebene ASIC Prototyp alle Anforderungen, die vom Experiment an die Ausleseelektronik gestellt werden.
Conclusion Scale Integration Based on the results of spike-field coherence, the underlying process of shortterm memory seems to involve networks of different sizes within and, most probably, beyond prefrontal cortex. Spikes, which were generated by single neurons, cooperate with local field potentials, which were the slower fluctuations of the environment. Although differences among behavioral conditions appear to be based on rather few instances of phase-locked spikes, the task-related effects on spike-field coherence are highly reliable and cannot be explained by chance, as the comparison of results from experimental and simulated data shows. The differential locking of prefrontal neuron populations with two different frequency bands in their input signals suggests that neuronal activity underlying short-term memory in prefrontal cortex transiently engages cortical circuits on different spatial scales, probably in order to coordinate distributed processes. NeuroXidence method and Synchronizedfiring Based on the results of the calibration datasets, for bi- and multi-variate cases, the extension of NeuroXidence remains its sensitivity and reliability of detecting coordinate firing events for different processes. Based on this extension of NeuroXidence, we demonstrated that in monkey’s prefrontal cortex during short-term memory task, encoding and maintenance of the information rely on the formation of neuronal assemblies characterized by precise and reliable synchronization of spiking activity on a millisecond time scale, which is consistent with the results from spike-spike coherence. The task and performance dependent modulation of synchrony reflects the dynamic formation of group of neurons has large effect on short-term-memory.