Accurate spectroscopy of highly-charged high-Z ions in a storage ring is demonstrated to be feasible by the use of specially adapted crystal optics. The method has been applied for the measurement of the 1s Lamb shift in hydrogen-like gold (Au+78) in a storage ring through spectroscopy of the Lyman x-rays. This measurement represents the first result obtained for a high-Z element using high-resolution wavelength-dispersive spectroscopy in the hard x-ray regime, paving the way for sensitivity to higher- order QED effects.
In summary, the cooled heavy-ion beams of the ESR storage ring offer excellent experimental conditions for a precise study of the effects of QED in the groundstate of high-Z one- and two-electron ions. This has been demonstrated within the series of experiments conducted at the electron cooler device as well as at the gasjet target. In this work we have used a recently developed experimental approach to obtain the first direct measurement of the two-electron contributions to the ground state binding energy of helium-like uranium. By employing our method, all one-electron contributions to the binding energy such as finite-nuclear size corrections and the one-electron self energy cancel out completely. Note, this is a distinctive feature of this particular kind of QED test and is in contrast to all other tests of bound state QED for high-Z ions such as 1s Lamb shift (in one-electron systems), g-factor of bound electrons, or hyperfine splitting. Compared to former investigations conducted at the superEBIT in Livermore we could already substantially improve the statistical accuracy and extend studies to the higher-Z regime. Moreover, our result has reached a sensitivity on specific two-electron QED contributions. Our value agrees with the theoretical predictions within the experimental uncertainty. Similar to the superEBIT experiment possible sources of systematic errors are essentially eliminated and the final result is limited only by counting statistics. For the case of the 1s Lamb shift in hydrogen-like uranium, the achieved accuracy of +- 4.2 eV is a substantial improvement by a factor of 3 compared to the most precise value up to now [44] (see Fig. 5.6). Our result already provides a test of the first-order QED contributions at the 1.5% level and only a slight improvement is required in order to achieve a sensitivity to QED contributions beyond first-order SE and VP.
In this paper, we present an experimental and theoretical study of excitation processes for the heaviest stable helium-like ion, that is, He-like uranium occurring in relativistic collisions with hydrogen and argon targets. In particular, we concentrate on angular distributions of the characteristic Kα radiation following the K → L excitation of He-like uranium. We pay special attention to the magnetic sub-level population of the excited 1s2lj states, which is directly related to the angular distribution of the characteristic Kα radiation. We show that the experimental data can be well described by calculations taking into account the excitation by the target nucleus as well as by the target electrons. Moreover, we demonstrate for the first time an important influence of the electron-impact excitation process on the angular distributions of the Kα radiation produced by excitation of He-like uranium in collisions with different targets.
The process of electron-loss to the continuum (ELC) has been studied for the collision systems U28++H2 at a collision energy of 50 MeV/u, U28++N2 at 30 MeV/u, and U28++Xe at 50 MeV/u. The energy distributions of cusp electrons emitted at an angle of 0∘ with respect to the projectile beam were measured using a magnetic forward-angle electron spectrometer. For these collision systems far from equilibrium charge state, a significantly asymmetric cusp shape is observed. The experimental results are compared to calculations based on first-order perturbation theory, which predict an almost symmetric cusp shape. Some possible reasons for this discrepancy are discussed.
Impact parameter sensitive study of inner-shell atomic processes in Xe54+, Xe52+ → Xe collisions
(2020)
In this work, we present a pilot experiment in the experimental storage ring (ESR) at GSI devoted to impact parameter sensitive studies of inner shell atomic processes for bare and He-like xenon ions (Xe54+, Xe52+) colliding with neutral xenon gas atoms. The projectile and target x-rays have been measured at different observation angles for all impact parameters as well as for the impact parameter range of ∼35 - 70 fm.
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U92+. Owing to the improved detector technology, a significant gain in precision of the present polarization measurement is achieved compared to the previously published results. The obtained data confirms that for medium-Z ions such as Xe, the REC process is a source of highly polarized x rays which can easily be tuned with respect to the degree of linear polarization and the photon energy. We argue, in particular, that for relatively low energies the photons emitted under large angles are almost fully linear polarized.
An experiment addressing electron capture (EC) decay of hydrogen-like 142Pm60+ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7)s−1 for automatic analysis and 0.0141(7)s−1 for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).
The electron-capture process was studied for Xe54+ colliding with H2 molecules at the internal gas target of the Experimental Storage Ring (ESR) at GSI, Darmstadt. Cross-section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogenlike ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron-capture data were recorded at the intermediate and, in particular, the low-collision-energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data are found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.
We report the first measurement of low-energy proton-capture cross sections of 124Xe in a heavy-ion storage ring. 124Xe54+ ions of five different beam energies between 5.5 and 8 AMeV were stored to collide with a windowless hydrogen target. The 125Cs reaction products were directly detected. The interaction energies are located on the high energy tail of the Gamow window for hot, explosive scenarios such as supernovae and x-ray binaries. The results serve as an important test of predicted astrophysical reaction rates in this mass range. Good agreement in the prediction of the astrophysically important proton width at low energy is found, with only a 30% difference between measurement and theory. Larger deviations are found above the neutron emission threshold, where also neutron and γ widths significantly impact the cross sections. The newly established experimental method is a very powerful tool to investigate nuclear reactions on rare ion beams at low center-of-mass energies.
The 124Xe(p,γ) reaction has been measured for the first time at energies around the Gamow window by using stored ions at the ESR facility. The desired beam energies below 10 MeV/u introduce new experimental challenges like windowless ions detection under UHV conditions, extremely short beam lifetimes and efficient beam deceleration and cooling, all of which have been successfully met.