Refine
Document Type
- Article (3)
- Conference Proceeding (1)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Heavy ion storage ring (1)
- Inverse kinematics (1)
- Isoscalar giant resonances (1)
- Mφs (1)
- Orbital electron capture (1)
- S1PR4 (1)
- Single particle decay spectroscopy (1)
- Storage ring (1)
- Two body weak decay (1)
- psoriasis (1)
A new technique developed for measuring nuclear reactions at low momentum transfer with stored beams in inverse kinematics was successfully used to study isoscalar giant resonances. The experiment was carried out at the experimental heavy-ion storage ring (ESR) at the GSI facility using a stored 58Ni beam at 100 MeV/u and an internal helium gas-jet target. In these measurements, inelastically scattered α-recoils at very forward center-of-mass angles (θcm ≤ 1.5°) were detected with a dedicated setup, including ultra-high vacuum compatible detectors. Experimental results indicate a dominant contribution of the isoscalar giant monopole resonance at this very forward angular range. It was found that the monopole contribution exhausts 79+12−11% of the energy-weighted sum rule (EWSR), which agrees with measurements performed in normal kinematics. This opens up the opportunity to investigate the giant resonances in a large domain of unstable and exotic nuclei in the near future. It is a fundamental milestone towards new nuclear reaction studies with stored ion beams.
An experiment addressing electron capture (EC) decay of hydrogen-like 142Pm60+ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7)s−1 for automatic analysis and 0.0141(7)s−1 for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).
The sphingolipid sphingosine‐1‐phosphate (S1P) fulfills distinct functions in immune cell biology via binding to five G protein‐coupled receptors. The immune cell‐specific sphingosine‐1‐phosphate receptor 4 (S1pr4) was connected to the generation of IL‐17‐producing T cells through regulation of cytokine production in innate immune cells. Therefore, we explored whether S1pr4 affected imiquimod‐induced murine psoriasis via regulation of IL‐17 production. We did not observe altered IL‐17 production, although psoriasis severity was reduced in S1pr4‐deficient mice. Instead, ablation of S1pr4 attenuated the production of CCL2, IL‐6, and CXCL1 and subsequently reduced the number of infiltrating monocytes and granulocytes. A connection between S1pr4, CCL2, and Mϕ infiltration was also observed in Zymosan‐A induced peritonitis. Boyden chamber migration assays functionally linked reduced CCL2 production in murine skin and attenuated monocyte migration when S1pr4 was lacking. Mechanistically, S1pr4 signaling synergized with TLR signaling in resident Mϕs to produce CCL2, likely via the NF‐κB pathway. We propose that S1pr4 activation enhances TLR response of resident Mϕs to increase CCL2 production, which attracts further Mϕs. Thus, S1pr4 may be a target to reduce perpetuating inflammatory responses.
8th International Conference on Nuclear Physics at Storage Rings Stori11, October 9-14, 2011 Laboratori Nazionale di Frascati, Italy.
Storage rings offer the possibility of measuring proton- and alpha-induced reactions in inverse kinematics. The combination of this approachwith a radioactive beamfacility allows, in principle, the determination of the respective cross sections for radioactive isotopes. Such data are highly desired for a better understanding of astrophysical nucleosynthesis processes like the p-process. A pioneering experiment has been performed at the Experimental Storage Ring (ESR) at GSI using a stable 96Ru beam at 9-11 AMeV and a hydrogen target. Monte-Carlo simulations of the experiment were made using the Geant4 code. In these simulations, the experimental setup is described in detail and all reaction channels can be investigated. Based on the Geant4 simulations, a prediction of the shape of different spectral components can be performed. A comparison of simulated predictions with the experimental results shows a good agreement and allows the extraction of the cross section.