Refine
Document Type
- Article (10)
- Doctoral Thesis (1)
Language
- English (11)
Has Fulltext
- yes (11)
Is part of the Bibliography
- no (11)
Keywords
Institute
We present novel measurements of five short-lived brominated source gases (CH2Br2, CHBr3, CH2ClBr, CHCl2Br and CHClBr2) obtained using a gas chromatograph-mass spectrometer system on board the High Altitude and Long Range Research Aircraft (HALO). The instrument is extremely sensitive due to the use of chemical ionisation, allowing detection limits in the lower parts per quadrillion (10-15) range. Data from three campaigns using the HALO aircraft are presented, where the Upper Troposphere/Lower Stratosphere (UTLS) of the Northern Hemisphere mid to high latitudes were sampled during winter and during late summer to early fall. We show that an observed decrease with altitude in the stratosphere is consistent with the relative lifetimes of the different compounds. Distributions of the five source gases and total organic bromine just below the tropopause shows an increase in mixing ratio with latitude, in particular during polar winter. This increase in mixing ratio is explained by increasing lifetimes at higher latitudes during winter. As the mixing ratio at the extratropical tropopause are generally higher than those derived for the tropical tropopause, extratropical troposphere-to-stratosphere transport will result in elevated levels of organic bromine in comparison to air transported over the tropical tropopause. The observations are compared to model estimates using different emission scenarios. A scenario which has emissions most strongly concentrated to low latitudes cannot reproduce the observed latitudinal distributions and will tend to overestimate bromine input through the tropical tropopause from CH2Br2 and CHBr3. Consequently, the scenario also overestimates the amount of brominated organic gases in the stratosphere. The two scenarios with the highest overall emissions of CH2Br2 tend to overestimate mixing ratios at the tropical tropopause but are in much better agreement with extratropical tropopause values, showing that not only total emissions but also latitudinal distributions in the emissions are of importance. While an increase in tropopause values with latitude is reproduced with all emission scenarios during winter, the simulated extratropical tropopause values are on average lower than the observations during late summer to fall. We show that a good knowledge of the latitudinal distribution of tropopause mixing ratios and of the fractional contributions of tropical and extratropical air is needed to derive stratospheric inorganic bromine in the lowermost stratosphere from observations. Depending on the underlying emission scenario, differences of a factor 2 in reactive bromine derived from observations and model outputs are found for the lowermost stratosphere, based on source gas injection. We conclude that a good representation of the contributions of different source regions is required in models for a robust assessment of the role of short-lived halogen source gases on ozone depletion in the UTLS.
Ziel der Arbeit war es, die Flugzeitmassenspektrometrie als neue Analysemethode für die instrumentelle Analytik halogenierter Spurengase in der Luft zu etablieren. Die grundle-gende Motivation dafür ist, dass anthropogene Emissionen vieler Vertreter dieser Sub-stanzklasse einen negativen Einfluss auf die Umwelt zeigen: in der Atmosphäre agieren die Substanzen bzw. ihre Abbauprodukte als Katalysatoren für den stratosphärischen Ozonab-bau und verstärken den Strahlungsantrieb der Erde durch Absorption elektromagnetischer Strahlung im sogenannten atmosphärischen Fenster. Um diese Effekte und deren Auswir-kung quantifizieren zu können, ist es notwendig, Konzentrationen und Trends der Substan-zen in der Atmosphäre zu überwachen. Nur so können Gegenmaßnahmen wie Produktions-reglementierungen geplant und bewertet werden. In Kombination mit inverser Modellie-rung können zudem Rückschlüsse über tatsächlich emittierten Mengen gezogen werden. Dies stellt den Anspruch an die Analytik, sehr geringe Mengen dieser Gase sehr präzise quantifizieren zu können, um auch schwache Trends zu erkennen. Zudem muss die Analy-semethode die Möglichkeit zu bieten, mit der wachsenden Anzahl bekannter und zu über-wachender Substanzen Schritt zu halten. Besonders für letzteren Aspekt bietet die Flug-zeitmassenspektrometrie einen entscheidenden Vorteil gegenüber der „konventionellen“ Methode, der Quadrupolmassenspektrometrie: sie zeichnet das gesamten Massenspektrum auf ohne dadurch an Empfindlichkeit einzubüßen. Um das atmosphärische Mischungsver-hältnis von Substanzen im Bereich von pmol mol−1 bis fmol mol−1 bestimmen zu können, muss das Quadrupolmassenspektrometer im Single Ion Monitoring Modus betrieben wer-den – so wird zwar eine hohe Sensitivität erreicht, es wird aber auch nur die Intensität eines bestimmten Masse zu Ladungsverhältnisses (kurz: Masse) zu einem Zeitpunkt aufgezeich-net. Ein Flugzeitmassenspektrometer hingegen extrahiert Ionen mit einer Frequenz im Ki-loherzbereich und zeichnet für jede Extraktion das vollständige Flugzeitspektrum und da-mit Massenspektrum auf.
Aufgabe dieser Arbeit war es, ein Flugzeitmassenspektrometer mit vorgeschalteter Pro-benanreicherungseinheit sowie Gaschromatograph zur Trennung des Subtanzgemisches vor der Detektion aufzubauen und Werkzeuge zur Datenauswertung zu entwickeln. Um einen zukünftigen Feldeinsatz vorzubereiten, sollte der Aufbau möglichst kompakt, mobil und vollständig automatisiert sein. Anschließend sollte Empfindlichkeit, Präzision und dynami-scher Messbereich geprüft, optimiert und die Anwendbarkeit zur Analyse halogenierter Spurengase gezeigt werden. Die Ergebnisse aus der in der vorliegenden Arbeit präsentier-ten Geräteentwicklung finden sich in drei Publikationen wieder, welche in thematischer Reihenfolge die Probenanreicherung (Obersteiner et al., 2016b), den Vergleich von Quadrupol- und Flugzeitmassenspektrometrie (Hoker et al., 2015) sowie Eigenschaften und Anwendung des neuen Aufbaus (Obersteiner et al., 2016a) behandeln. Mit den genannten Aufsätzen ist die Arbeitsgruppe Engel weltweit die erste, welche hochpräzise Analytik ha-logenierter Spurengase routinemäßig mittels Flugzeitmassenspektrometrie durchführt. Der nächste Schritt ist der Übergang von der Laboranwendung zur Feldmessung, z.B. in Form von bodenbasierter in situ Analyse troposphärischer Luftmassen am Taunus Observatorium auf dem Kleinen Feldberg. Da es bisher keine Messstation für die hier beschriebene analy-tische Fragestellung in Deutschland gibt, könnte eine deutliche Verbesserung der Überwa-chung halogenierter Treibhausgase und ozonzerstörender Substanzen in Europa erzielt wer-den. Weiterhin wäre eine Flugzeugapplikation in Zukunft denkbar, welche neben der durch das Flugzeitmassenspektrometer abgedeckten Substanzbandbreite auch von dessen hoher möglicher Spektrenrate profitieren könnte. In Kombination mit Hochgeschwindigkeitsgas-chromatographie könnte eine bisher unerreichte Zeitauflösung der Beprobung der Atmo-sphäre mittels Gaschromatographie-Massenspektrometrie erzielt werden.
We present the application of Time-of-Flight Mass Spectrometry (TOF MS) for the analysis of halocarbons in the atmosphere, after cryogenic sample preconcentration and gas chromatographic separation. For the described field of application, the Quadrupole Mass Spectrometer (QP MS) is the state-of-the-art detector. This work aims at comparing two commercially available instruments, a QP MS and a TOF MS with respect to mass resolution, mass accuracy, sensitivity, measurement precision and detector linearity. Both mass spectrometers are operated on the same gas chromatographic system by splitting the column effluent to both detectors. The QP MS had to be operated in optimised Single Ion Monitoring (SIM) mode to achieve a sensitivity which could compete with the TOF MS. The TOF MS provided full mass range information in any acquired mass spectrum without losing sensitivity. Whilst the QP MS showed the performance already achieved in earlier tests, the sensitivity of the TOF MS was on average higher than that of the QP MS in the "operational" SIM mode by a factor of up to 3 reaching detection limits of less than 0.2 pg. Measurement precision determined for the whole analytical system was up to 0.2% depending on substance and sampled volume. The TOF MS instrument used for this study displayed significant non-linearities of up to 10% for two third of all analysed substances.
Background: Point of care devices for performing targeted coagulation substitution in bleeding patients have become increasingly important in recent years. New on the market is the Quantra® from HemoSonics (LC, Charlottesville, VA, US). It uses sonorheometry, a sonic estimation of elasticity via resonance (SEER), a novel ultrasound-based technology that measures viscoelastic properties of whole blood. Several studies have already shown the comparability with devices already established on the market such as the ROTEM® (TEM International GmbH, Munich, Germany).
Objective: In contrast to existing studies, the planned study will be the first prospective interventional study using the new Quantra® system in a cardiac surgical patient cohort. The aim is to investigate the non-inferiority between an already existing coagulation algorithm, based on ROTEM®/Multiplate®, and a new algorithm based on the Quantra®, for the treatment of coagulopathic cardiac surgical patients.
Methods: The study is divided into two phases. In an initial observation phase, whole blood samples of 20 patients will be analyzed using both ROTEM®/Multiplate® and Quantra® obtained at three defined points of time (prior to surgery, after completion of cardiopulmonary bypass, on arrival in the intensive care unit). The obtained threshold values will be used to create an algorithm for hemotherapy. In a second intervention phase, the new algorithm will be tested against an algorithm used routineously for years at our department for non-inferiority.
Results: The main objective of the examination is the cumulative loss of blood within 24 hours after surgery. Statistical calculations based on literature and in-house data suggest that the new algorithm is not inferior if the difference in cumulative blood loss is < 150ml/24 h.
Conclusions: Because of the comparability of the Quantra® sonorheometry system with ROTEM® rotational thromboelastometric measurement methods, the existing hemotherapy treatment algorithm can be adapted to the Quantra device with a proof of non-inferiority. Clinical Trial: International Registered Report Identifier (IRRID): clinicaltrials.gov: NCT03902275
We present the characterization and application of a new gas chromatography time-of-flight mass spectrometry instrument (GC-TOFMS) for the quantitative analysis of halocarbons in air samples. The setup comprises three fundamental enhancements compared to our earlier work (Hoker et al., 2015): (1) full automation, (2) a mass resolving power R = m/Δm of the TOFMS (Tofwerk AG, Switzerland) increased up to 4000 and (3) a fully accessible data format of the mass spectrometric data. Automation in combination with the accessible data allowed an in-depth characterization of the instrument. Mass accuracy was found to be approximately 5 ppm in mean after automatic recalibration of the mass axis in each measurement. A TOFMS configuration giving R = 3500 was chosen to provide an R-to-sensitivity ratio suitable for our purpose. Calculated detection limits are as low as a few femtograms by means of the accurate mass information. The precision for substance quantification was 0.15 % at the best for an individual measurement and in general mainly determined by the signal-to-noise ratio of the chromatographic peak. Detector non-linearity was found to be insignificant up to a mixing ratio of roughly 150 ppt at 0.5 L sampled volume. At higher concentrations, non-linearities of a few percent were observed (precision level: 0.2 %) but could be attributed to a potential source within the detection system. A straightforward correction for those non-linearities was applied in data processing, again by exploiting the accurate mass information. Based on the overall characterization results, the GC-TOFMS instrument was found to be very well suited for the task of quantitative halocarbon trace gas observation and a big step forward compared to scanning, quadrupole MS with low mass resolving power and a TOFMS technique reported to be non-linear and restricted by a small dynamical range.
We present a compact and versatile cryofocusing– thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. -80°C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. 200°C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography – mass spectrometry (GC–MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately -80 to +150°C and a substance mixing ratio range of less than 1 ppt (pmol mol−1)to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC–MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOSTMS (Gas chromatograph for the Observation of Tracers – coupled with a Mass Spectrometer).
We present a compact and versatile cryofocusing–thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. −80 °C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography – mass spectrometry (GC–MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately −80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol−1) to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC–MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers – coupled with a Mass Spectrometer).
We present the characterization and application of a new gas chromatography time-of-flight mass spectrometry instrument (GC-TOFMS) for the quantitative analysis of halocarbons in air samples. The setup comprises three fundamental enhancements compared to our earlier work (Hoker et al., 2015): (1) full automation, (2) a mass resolving power R = m/Δm of the TOFMS (Tofwerk AG, Switzerland) increased up to 4000 and (3) a fully accessible data format of the mass spectrometric data. Automation in combination with the accessible data allowed an in-depth characterization of the instrument. Mass accuracy was found to be approximately 5 ppm in mean after automatic recalibration of the mass axis in each measurement. A TOFMS configuration giving R = 3500 was chosen to provide an R-to-sensitivity ratio suitable for our purpose. Calculated detection limits are as low as a few femtograms by means of the accurate mass information. The precision for substance quantification was 0.15 % at the best for an individual measurement and in general mainly determined by the signal-to-noise ratio of the chromatographic peak. Detector non-linearity was found to be insignificant up to a mixing ratio of roughly 150 ppt at 0.5 L sampled volume. At higher concentrations, non-linearities of a few percent were observed (precision level: 0.2 %) but could be attributed to a potential source within the detection system. A straightforward correction for those non-linearities was applied in data processing, again by exploiting the accurate mass information. Based on the overall characterization results, the GC-TOFMS instrument was found to be very well suited for the task of quantitative halocarbon trace gas observation and a big step forward compared to scanning, quadrupole MS with low mass resolving power and a TOFMS technique reported to be non-linear and restricted by a small dynamical range.
We present the application of time-of-flight mass spectrometry (TOF MS) for the analysis of halocarbons in the atmosphere after cryogenic sample preconcentration and gas chromatographic separation. For the described field of application, the quadrupole mass spectrometer (QP MS) is a state-of-the-art detector. This work aims at comparing two commercially available instruments, a QP MS and a TOF MS, with respect to mass resolution, mass accuracy, stability of the mass axis and instrument sensitivity, detector sensitivity, measurement precision and detector linearity. Both mass spectrometers are operated on the same gas chromatographic system by splitting the column effluent to both detectors. The QP MS had to be operated in optimised single ion monitoring (SIM) mode to achieve a sensitivity which could compete with the TOF MS. The TOF MS provided full mass range information in any acquired mass spectrum without losing sensitivity. Whilst the QP MS showed the performance already achieved in earlier tests, the sensitivity of the TOF MS was on average higher than that of the QP MS in the "operational" SIM mode by a factor of up to 3, reaching detection limits of less than 0.2 pg. Measurement precision determined for the whole analytical system was up to 0.2% depending on substance and sampled volume. The TOF MS instrument used for this study displayed significant non-linearities of up to 10% for two-thirds of all analysed substances.
Anthropogenic trace gases often exhibit interhemispheric gradients because of larger emissions in the Northern Hemisphere. Depending on a tracer's emission pattern and sink processes, trace gas observations can thus be used to investigate interhemispheric transport in the atmosphere. Vice versa, understanding interhemispheric transport is important for interpreting spatial tracer distributions and for inferring emissions. We combine several data sets from the upper troposphere (UT) to investigate the interhemispheric gradient of sulfur hexafluoride (SF6) covering latitudes from ∼ 80∘ N to ∼ 60∘ S: canister sampling based measurements from the IAGOS-CARIBIC infrastructure and data from the in-flight gas chromatography instruments GhOST (Gas chromatograph for Observational Studies using Tracers) and UCATS (Unmanned aircraft systems Chromatograph for Atmospheric Trace Species). The interhemispheric gradient of SF6 in the UT is found to be weaker than near the surface. Using the concept of a lag time removes the increasing trend from the time series. At the most southern latitudes, a lag time of over 1 year with respect to the northern mid-latitude surface is derived, and lag times decrease over the period 2006–2020 in the extra-tropics and the southern tropics. Observations are compared to results from the two-dimensional Advanced Global Atmospheric Gases Experiment (AGAGE) 12-box model. Based on Emissions Database for Global Atmospheric Research (EDGAR 7) emissions, fair agreement of lag times is obtained for the Northern Hemisphere, but southern hemispheric air appears too “old”. This is consistent with earlier findings that transport from the northern extra-tropics into the tropics is too slow in many models. The influence of the emission scenario and the model transport scheme are evaluated in sensitivity runs. It is found that EDGAR 7 underestimates emissions of SF6 globally and in the Southern Hemisphere, whereas northern extra-tropical emissions seem overestimated. Faster southward transport from the northern extra-tropics would be needed in the model, but transport from the southern tropics into the southern extra-tropics appears too fast.