Refine
Year of publication
Document Type
- Article (28)
- Doctoral Thesis (1)
- Working Paper (1)
Has Fulltext
- yes (30)
Is part of the Bibliography
- no (30)
Keywords
- Musculoskeletal system (3)
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- Knees (2)
- kinematic analysis (2)
- musculoskeletal disorders (2)
- ACLF (1)
- AD patients (1)
- Anatomy (1)
Institute
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
Triathletes often experience incoordination at the start of a transition run (TR); this is possibly reflected by altered joint kinematics. In this study, the first 20 steps of a run after a warm-up run (WR) and TR (following a 90 min cycling session) of 16 elite, male, long-distance triathletes (31.3 ± 5.4 years old) were compared. Measurements were executed on the competition course of the Ironman Frankfurt in Germany. Pacing and slipstream were provided by a cyclist in front of the runner. Kinematic data of the trunk and leg joints, step length, and step rate were obtained using the MVN Link inertial motion capture system by Xsens. Statistical parametric mapping was used to compare the active leg (AL) and passive leg (PL) phases of the WR and TR. In the TR, more spinal extension (~0.5–1°; p = 0.001) and rotation (~0.2–0.5°; p = 0.001–0.004), increases in hip flexion (~3°; ~65% AL−~55% PL; p = 0.001–0.004), internal hip rotation (~2.5°; AL + ~0–30% PL; p = 0.001–0.024), more knee adduction (~1°; ~80–95% AL; p = 0.001), and complex altered knee flexion patterns (~2–4°; AL + PL; p = 0.001–0.01) occurred. Complex kinematic differences between a WR and a TR were detected. This contributes to a better understanding of the incoordination in transition running.
Background: In general, the prevalence of work-related musculoskeletal disorders (WMSD) in dentistry is high, and dental assistants (DA) are even more affected than dentists (D). Furthermore, differentiations between the fields of dental specialization (e.g., general dentistry, endodontology, oral and maxillofacial surgery, or orthodontics) are rare. Therefore, this study aims to investigate the ergonomic risk of the aforementioned four fields of dental specialization for D and DA on the one hand, and to compare the ergonomic risk of D and DA within each individual field of dental specialization. Methods: In total, 60 dentists (33 male/27 female) and 60 dental assistants (11 male/49 female) volunteered in this study. The sample was composed of 15 dentists and 15 dental assistants from each of the dental field, in order to represent the fields of dental specialization. In a laboratory setting, all tasks were recorded using an inertial motion capture system. The kinematic data were applied to an automated version of the Rapid Upper Limb Assessment (RULA). Results: The results revealed significantly reduced ergonomic risks in endodontology and orthodontics compared to oral and maxillofacial surgery and general dentistry in DAs, while orthodontics showed a significantly reduced ergonomic risk compared to general dentistry in Ds. Further differences between the fields of dental specialization were found in the right wrist, right lower arm, and left lower arm in DAs and in the neck, right wrist, right lower arm, and left wrist in Ds. The differences between Ds and DAs within a specialist discipline were rather small. Discussion: Independent of whether one works as a D or DA, the percentage of time spent working in higher risk scores is reduced in endodontologists, and especially in orthodontics, compared to general dentists or oral and maxillofacial surgeons. In order to counteract the development of WMSD, early intervention should be made. Consequently, ergonomic training or strength training is recommended.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.
Background; Musculoskeletal disorders (MSD) are a common health problem among dentists. Dental treatment is mainly performed in a sitting position. The aim of the study was to quantify the effect of different ergonomic chairs on the sitting position. In addition, it was tested if the sitting position of experienced workers is different from a non-dental group.
Methods; A total of 59 (28 m/31f) subjects, divided into two dentist groups according to their work experience (students and dentists (9 m/11f) < 10 years, dentists (9 m/10f) ≥ 10 years) and a control group (10 m/10f) were measured. A three-dimensional back scanner captured the bare back of all subjects sitting on six dentist’s chairs of different design. Initially, inter-group comparisons per chair, firstly in the habitual and secondly in the working postures, were carried out. Furthermore, inter-chair comparison was conducted for the habitual as well as for the working postures of all subjects and for each group. Finally, a comparison between the habitual sitting posture and the working posture for each respective chair (intra-chair comparison) was conducted (for all subjects and for each group). In addition, a subjective assessment of each chair was made.
For the statistical analysis, non-parametric tests were conducted and the level of significance was set at 5%.
Results: When comparing the three subject groups, all chairs caused a more pronounced spinal kyphosis in experienced dentists. In both conditions (habitual and working postures), a symmetrical sitting position was assumed on each chair.
The inter-chair comparisons showed no differences regarding the ergonomic design of the chairs. The significances found in the inter-chair comparisons were all within the measurementerror and could, therefore, be classified as clinically irrelevant.
The intra-chair comparison (habitual sitting position vs. working sitting position) illustrated position-related changes in the sagittal, but not in the transverse, plane. These changes were only position-related (forward leaned working posture) and were not influenced by the ergonomic sitting design of the respective chair. There are no differences between the groups in the subjective assessment of each chair.
Conclusions; Regardless of the group or the dental experience, the ergonomic design of the dentist’s chair had only a marginal influence on the upper body posture in both the habitual and working sitting postures. Consequently, the focus of the dentist’s chair, in order to minimize MSD, should concentrate on adopting a symmetrical sitting posture rather than on its ergonomic design.
Adult neurogenesis is regulated by stem cell niche-derived extrinsic factors and cell-intrinsic regulators, yet the mechanisms by which niche signals impinge on the activity of intrinsic neurogenic transcription factors remain poorly defined. Here, we report that MEIS2, an essential regulator of adult SVZ neurogenesis, is subject to posttranslational regulation in the SVZ olfactory bulb neurogenic system. Nuclear accumulation of MEIS2 in adult SVZ-derived progenitor cells follows downregulation of EGFR signaling and is modulated by methylation of MEIS2 on a conserved arginine, which lies in close proximity to nested binding sites for the nuclear export receptor CRM1 and the MEIS dimerization partner PBX1. Methylation impairs interaction with CRM1 without affecting PBX1 dimerization and thereby allows MEIS2 nuclear accumulation, a prerequisite for neuronal differentiation. Our results describe a form of posttranscriptional modulation of adult SVZ neurogenesis whereby an extrinsic signal fine-tunes neurogenesis through posttranslational modification of a transcriptional regulator of cell fate.
Purpose: Scientific and clinical achievements in radiation, medical, and surgical oncology are changing the landscape of interdisciplinary oncology. The German Society for Radiation Oncology (DEGRO) working group of young clinicians and scientists (yDEGRO) and the DEGRO representation of associate and full professors (AKRO) are aware of the essential role of radiation oncology in multidisciplinary treatment approaches. Together, yDEGRO and AKRO endorsed developing a German radiotherapy & radiation oncology vision 2030 to address future challenges in patient care, research, and education. The vision 2030 aims to identify priorities and goals for the next decade in the field of radiation oncology. Methods: The vision development comprised three phases. During the first phase, areas of interest, objectives, and the process of vision development were defined jointly by the yDEGRO, AKRO, and the DEGRO board. In the second phase, a one-day strategy retreat was held to develop AKRO and yDEGRO representatives’ final vision from medicine, biology, and physics. The third phase was dedicated to vision interpretation and program development by yDEGRO representatives. Results: The strategy retreat’s development process resulted in conception of the final vision “Innovative radiation oncology Together – Precise, Personalized, Human.” The first term “Innovative radiation oncology” comprises the promotion of preclinical research and clinical trials and highlights the development of a national committee for strategic development in radiation oncology research. The term “together” underpins collaborations within radiation oncology departments as well as with other partners in the clinical and scientific setting. “Precise” mainly covers technological precision in radiotherapy as well as targeted oncologic therapeutics. “Personalized” emphasizes biology-directed individualization of radiation treatment. Finally, “Human” underlines the patient-centered approach and points towards the need for individual longer-term career curricula for clinicians and researchers in the field. Conclusion: The vision 2030 balances the ambition of physical, technological, and biological innovation as well as a comprehensive, patient-centered, and collaborative approach towards radiotherapy & radiation oncology in Germany.
Zur ergonomischen Beurteilung von Arbeitsplätzen werden „ergonomic risk assessment tools“ (ERAT) verwendet. Mithilfe dieser kann die körperliche Belastung evaluiert und hinsichtlich eines biomechanischen Überlastungsrisikos bewertet werden. Dazu gehören neben Eigenangaben auch observatorische Methoden, deren Ergebnisse in Punktwerten („Scores“) zusammengefasst werden, wie z. B. die RULAMethode („rapid upper limb assessment“). Durch die technische Weiterentwicklung direkter Messmethoden können inertiale Motion-Capture-Systeme im 21. Jahrhundert präzise und kontinuierliche objektive Daten liefern. In einem neuen Ansatz wurde die observatorische Scoring-Methode RULA modifiziert und auf die digital erhobenen Daten angewendet, was differenzierte ergonomische Betrachtungen ganzer Arbeitsabläufe ermöglicht.
Objective: The influence of the jaw position on postural control, body posture, walking and running pattern has been reported in the literature. All these movements have in common that a relatively small, but well controlled muscle activation is required. The induced effects on motor output through changed jaw positions have been small. Therefore, it has been questioned if it could still be observed in maximal muscle activation.
Method: Twenty-three healthy, mid age recreational runners (mean age = 34.0 ± 10.3 years) participated in this study. Three different jump tests (squat jump, counter movement jump, and drop jumps from four different heights) and three maximal strength tests (trunk flexion and extension, leg press of the right and left leg) were conducted. Four different dental occlusion conditions and an additional familiarization condition were tested. Subjects performed the tests on different days for which the four occlusion conditions were randomly changed.
Results: No familiarization effect was found. Occlusion conditions with a relaxation position and with a myocentric condylar position showed significantly higher values for several tests compared to the neutral condition and the maximal occlusion position. Significance was found in the squat jump, countermovement jump, the drop jump from 32cm and 40cm, trunk extension, leg press force and rate of force development. The effect due to the splint conditions is an improvement between 3% and 12% (min and max). No influence of the jaw position on symmetry or balance between extension and flexion muscle was found.
Conclusion: An influence of occlusion splints on rate of force development (RFD) and maximal strength tests could be confirmed. A small, but consistent increase in the performance parameters could be measured. The influence of the occlusion condition is most likely small compared to other influences as for example training status, age, gender and circadian rhythm.
Introduction: The effects of manipulated dental occlusion on body posture has been investigated quite often and discussed controversially in the literature. Far less attention has been paid to the influence of dental occlusion position on human movement. If human movement was analysed, it was mostly while walking and not while running. This study was therefore designed to identify the effect of lower jaw positions on running behaviour according to different dental occlusion positions.
Methods: Twenty healthy young recreational runners (mean age = 33.9±5.8 years) participated in this study. Kinematic data were collected using an eight-camera Vicon motion capture system (VICON Motion Systems, Oxford, UK). Subjects were consecutively prepared with four different dental occlusion conditions in random order and performed five running trials per test condition on a level walkway with their preferred running shoes. Vector based pattern recognition methods, in particular cluster analysis and support vector machines (SVM) were used for movement pattern identification.
Results: Subjects exhibited unique movement patterns leading to 18 clusters for the 20 subjects. No overall classification of the splint condition could be observed. Within individual subjects different running patterns could be identified for the four splint conditions. The splint conditions lead to a more symmetrical running pattern than the control condition.
Discussion: The influence of an occlusal splint on running pattern can be confirmed in this study. Wearing a splint increases the symmetry of the running pattern. A more symmetrical running pattern might help to reduce the risk of injuries or help in performance. The change of the movement pattern between the neutral condition and any of the three splint conditions was significant within subjects but not across subjects. Therefore the dental splint has a measureable influence on the running pattern of subjects, however subjects individuality has to be considered when choosing the optimal splint condition for a specific subject.