Refine
Document Type
- Article (4)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Genu valgum (1)
- Guiding growth (1)
- Leg axis (1)
- Lower limb deformities (1)
- Pediatric orthopedic (1)
- Radiological assessment (1)
- Reliability (1)
- Scheuermann’s disease (1)
- bracing (1)
- diagnosis (1)
Institute
- Medizin (4)
Background: Malalignments of the lower extremity are common reasons for orthopedic consultation because it may lead to osteoarthritis in adulthood. An accurate and reliable radiological assessment of lower limb alignment in children and adolescents is essential for clinical decision-making on treatment of limb deformities and for regular control after a surgical intervention.
Objective: First, does the analysis of full-length standing anteroposterior radiographs show a good intra- and interobserver reliability? Second, which parameter is most susceptible to observer-dependent errors? Third, what is the Standard Error of Measurement (SEM95%) of the absolute femoral and tibial length?
Methods: Two observers evaluated digital radiographs of 144 legs from 36 children and adolescents with pathological valgus alignment before a temporary hemiepiphysiodesis and before implant removal. Parameters included Mechanical Femorotibial Angle (MFA), Mechanical Axis Deviation (MAD), mechanical Lateral Distal Femoral Angle (mLDFA), mechanical Medial Proximal Tibial Angle (mMPTA), mechanical Lateral Proximal Femoral Angle (mLPFA), mechanical Lateral Distal Tibial Angle (mLDTA), Joint Line Convergence Angle (JLCA), femur length, tibial length. Intra- and interobserver reliability (ICC2,1), SEM95% and proportional errors were calculated.
Results: The intra- and interobserver reliability for almost all measurements was found to be good to excellent (Intra-ICC2,1: 0.849–0.999; Inter-ICC2,1: 0.864–0.996). The SEM95% of both observers was found to be ± 1.39° (MFA), ± 3.31 mm (MAD), ± 1.06° (mLDFA) and ± 1.29° (mMPTA). The proportional error of MAD and MFA is comparable (47.29% vs. 46.33%). The relevant knee joint surface angles show a lower proportional error for mLDFA (42.40%) than for mMPTA (51.60%). JLCA has a proportional error of 138%. Furthermore, the SEM95% for the absolute values of the femoral and tibial length was 4.53 mm for the femur and 3.12 mm for the tibia.
Conclusions: In conclusion, a precise malalignment measurement and the knowledge about SEM95% of the respective parameters are crucial for correct surgical or nonsurgical treatment. The susceptibility to error must be considered when interpreting malalignment analysis and must be considered when planning a surgical intervention. The results of the present study elucidate that MAD and MFA are equally susceptible to observer-dependent errors. This study shows good to excellent intra- and interobserver ICCs for all leg alignment parameters and joint surface angles, except for JLCA.
Trial registration: This study was registered with DRKS (German Clinical Trials Register) under the number DRKS00015053.
Level of evidence
I, Diagnostic Study.
Scoliosis and Scheuermann’s disease are common spinal deformities that affect a substantial population, particularly adolescents, often impacting their quality of life. This comprehensive review aims to present a detailed understanding of these conditions, their diagnosis, and various treatment strategies. Through an extensive exploration of current literature, the review discusses the etiology of these spinal deformities and the use of diagnostic tools such as X-rays and MRI. It further delves into the range of treatment options available, from conservative approaches such as physiotherapy and bracing to more invasive surgical interventions. The review underscores the necessity of an individualized treatment approach, taking into account factors such as the patient’s age, the severity of the curvature, and overall health. This all-encompassing perspective on scoliosis and Scheuermann’s disease will aid in evidence-based decision making in their management with the goal of improving patient outcomes
In recent years, the infrapatellar fat pad (IFP) has gained increasing research interest. The contribution of the IFP to the development and progression of knee osteoarthritis (OA) through extensive interactions with the synovium, articular cartilage, and subchondral bone is being considered. As part of the initiation process of OA, IFP secretes abundant pro-inflammatory mediators among many other factors. Today, the IFP is (partially) resected in most total knee arthroplasties (TKA) allowing better visualization during surgical procedures. Currently, there is no clear guideline providing evidence in favor of or against IFP resection. With increasing numbers of TKAs, there is a focus on preventing adverse postoperative outcomes. Therefore, anatomic features, role in the development of knee OA, and consequences of resecting versus preserving the IFP during TKA are reviewed in the following article.
The correction of valgus leg malalignment in children using implant-mediated growth guidance is widely used and effective. Despite the minimal invasive character of the procedure, a relevant number of patients sustain prolonged pain and limited mobility after temporary hemiepiphysiodesis. Our aim was to investigate implant-associated risk factors (such as implant position and screw angulation), surgical- or anesthesia-related risk factors (such as type of anesthesia, use, and duration), and pressure of tourniquet or duration of surgery for these complications. Thirty-four skeletally immature patients with idiopathic valgus deformities undergoing hemiepiphysiodesis plating from October 2018–July 2022 were enrolled in this retrospective study. Participants were divided into groups with and without prolonged complications (persistent pain, limited mobility of the operated knee between five weeks and six months) after surgery. Twenty-two patients (65%) had no notable complications, while twelve patients (35%) had prolonged complications. Both groups differed significantly in plate position relative to physis (p = 0.049). In addition, both groups showed significant differences in the distribution of implant location (p = 0.016). Group 1 had a shorter duration of surgery than group 2 (32 min vs. 38 min, p = 0.032) and a lower tourniquet pressure (250 mmHg vs. 270 mmHg, p = 0.019). In conclusion, simultaneous plate implantation at the femur and tibia and metaphyseal plate positioning resulted in prolonged pain and a delay of function. In addition, the amplitude of tourniquet pressure or duration of surgery could play a factor.