Cortical changes in epilepsy patients with focal cortical dysplasia: new insights with T2 mapping
(2020)
Background: In epilepsy patients with focal cortical dysplasia (FCD) as the epileptogenic focus, global cortical signal changes are generally not visible on conventional MRI. However, epileptic seizures or antiepileptic medication might affect normal-appearing cerebral cortex and lead to subtle damage. Purpose: To investigate cortical properties outside FCD regions with T2-relaxometry. Study Type: Prospective study. Subjects: Sixteen patients with epilepsy and FCD and 16 age-/sex-matched healthy controls. Field Strength/Sequence: 3T, fast spin-echo T2-mapping, fluid-attenuated inversion recovery (FLAIR), and synthetic T1-weighted magnetization-prepared rapid acquisition of gradient-echoes (MP-RAGE) datasets derived from T1-maps. Assessment: Reconstruction of the white matter and cortical surfaces based on MP-RAGE structural images was performed to extract cortical T2 values, excluding lesion areas. Three independent raters confirmed that morphological cortical/juxtacortical changes in the conventional FLAIR datasets outside the FCD areas were definitely absent for all patients. Averaged global cortical T2 values were compared between groups. Furthermore, group comparisons of regional cortical T2 values were performed using a surface-based approach. Tests for correlations with clinical parameters were carried out. Statistical Tests: General linear model analysis, permutation simulations, paired and unpaired t-tests, and Pearson correlations. Results: Cortical T2 values were increased outside FCD regions in patients (83.4 ± 2.1 msec, control group 81.4 ± 2.1 msec, P = 0.01). T2 increases were widespread, affecting mainly frontal, but also parietal and temporal regions of both hemispheres. Significant correlations were not observed (P ≥ 0.55) between cortical T2 values in the patient group and the number of seizures in the last 3 months or the number of anticonvulsive drugs in the medical history. Data Conclusion: Widespread increases in cortical T2 in FCD-associated epilepsy patients were found, suggesting that structural epilepsy in patients with FCD is not only a symptom of a focal cerebral lesion, but also leads to global cortical damage not visible on conventional MRI. Evidence Level: 21. Technical efficacy Stage: 3 J. MAGN. RESON. IMAGING 2020;52:1783–1789.
Multimodal quantitative mri reveals no evidence for tissue pathology in idiopathic cervical dystonia
(2019)
Background: While in symptomatic forms of dystonia cerebral pathology is by definition present, it is unclear so far whether disease is associated with microstructural cerebral changes in idiopathic dystonia. Previous quantitative MRI (qMRI) studies assessing cerebral tissue composition in idiopathic dystonia revealed conflicting results.
Objective: Using multimodal qMRI, the presented study aimed to investigate alterations in different cerebral microstructural compartments associated with idiopathic cervical dystonia in vivo.
Methods: Mapping of T1, T2, T∗2, and proton density (PD) was performed in 17 patients with idiopathic cervical dystonia and 29 matched healthy control subjects. Statistical comparisons of the parametric maps between groups were conducted for various regions of interest (ROI), including major basal ganglia nuclei, the thalamus, white matter, and the cerebellum, and voxel-wise for the whole brain.
Results: Neither whole brain voxel-wise statistics nor ROI-based analyses revealed significant group differences for any qMRI parameter under investigation.
Conclusions: The negative findings of this qMRI study argue against the presence of overt microstructural tissue change in patients with idiopathic cervical dystonia. The results seem to support a common view that idiopathic cervical dystonia might primarily resemble a functional network disease.
Magnetic resonance imaging (MRI) is the gold standard imaging technique for diagnosis and monitoring of many neurological diseases. However, the application of conventional MRI in clinical routine is mainly limited to the visual detection of macroscopic tissue pathology since mixed tissue contrasts depending on hardware and protocol parameters hamper its application for the assessment of subtle or diffuse impairment of the structural tissue integrity. Multiparametric quantitative (q)MRI determines tissue parameters quantitatively, enabling the detection of microstructural processes related to tissue remodeling in aging and neurological diseases. In contrast to measuring tissue atrophy via structural imaging, multiparametric qMRI allows for investigating biologically distinct microstructural processes, which precede changes of the tissue volume. This facilitates a more comprehensive characterization of tissue alterations by revealing early impairment of the microstructural integrity and specific disease-related patterns. So far, qMRI techniques have been employed in a wide range of neurological diseases, including in particular conditions with inflammatory, cerebrovascular and neurodegenerative pathology. Numerous studies suggest that qMRI might add valuable information, including the detection of microstructural tissue damage in areas appearing normal on conventional MRI and unveiling the microstructural correlates of clinical manifestations. This review will give an overview of current qMRI techniques, the most relevant tissue parameters and potential applications in neurological diseases, such as early (differential) diagnosis, monitoring of disease progression, and evaluating effects of therapeutic interventions.
Purpose: In the clinical routine, detection of focal cortical dysplasia (FCD) by visual inspection is challenging. Still, information about the presence and location of FCD is highly relevant for prognostication and treatment decisions. Therefore, this study aimed to develop, describe and test a method for the calculation of synthetic anatomies using multiparametric quantitative MRI (qMRI) data and surface-based analysis, which allows for an improved visualization of FCD.
Materials and Methods: Quantitative T1-, T2- and PD-maps and conventional clinical datasets of patients with FCD and epilepsy were acquired. Tissue segmentation and delineation of the border between white matter and cortex was performed. In order to detect blurring at this border, a surface-based calculation of the standard deviation of each quantitative parameter (T1, T2, and PD) was performed across the cortex and the neighboring white matter for each cortical vertex. The resulting standard deviations combined with measures of the cortical thickness were used to enhance the signal of conventional FLAIR-datasets. The resulting synthetically enhanced FLAIR-anatomies were compared with conventional MRI-data utilizing regions of interest based analysis techniques.
Results: The synthetically enhanced FLAIR-anatomies showed higher signal levels than conventional FLAIR-data at the FCD sites (p = 0.005). In addition, the enhanced FLAIR-anatomies exhibited higher signal levels at the FCD sites than in the corresponding contralateral regions (p = 0.005). However, false positive findings occurred, so careful comparison with conventional datasets is mandatory.
Conclusion: Synthetically enhanced FLAIR-anatomies resulting from surface-based multiparametric qMRI-analyses have the potential to improve the visualization of FCD and, accordingly, the treatment of the respective patients.
The detection of cortical malformations in conventional MR images can be challenging. Prominent examples are focal cortical dysplasias (FCD), the most common cause of drug‐resistant focal epilepsy. The two main MRI hallmarks of cortical malformations are increased cortical thickness and blurring of the gray (GM) and white matter (WM) junction. The purpose of this study was to derive synthetic anatomies from quantitative T1 maps for the improved display of the above imaging characteristics in individual patients.
On the basis of a T1 map, a mask comprising pixels with T1 values characteristic for GM is created from which the local cortical extent (CE) is determined. The local smoothness (SM) of the GM‐WM junctions is derived from the T1 gradient. For display of cortical malformations, the resulting CE and SM maps serve to enhance local intensities in synthetic double inversion recovery (DIR) images calculated from the T1 map.
The resulting CE‐ and/or SM‐enhanced DIR images appear hyperintense at the site of cortical malformations, thus facilitating FCD detection in epilepsy patients. However, false positives may arise in areas with naturally elevated CE and/or SM, such as large GM structures and perivascular spaces.
In summary, the proposed method facilitates the detection of cortical abnormalities such as cortical thickening and blurring of the GM‐WM junction which are typical FCD markers. Still, subject motion artifacts, perivascular spaces, and large normal GM structures may also yield signal hyperintensity in the enhanced synthetic DIR images, requiring careful comparison with clinical MR images by an experienced neuroradiologist to exclude false positives.
Background and purpose: In patients with epilepsies of structural origin, brain atrophy and pathological alterations of the tissue microstructure extending beyond the putative epileptogenic lesion have been reported. However, in patients without any evidence of epileptogenic lesions on diagnostic magnetic resonance imaging (MRI), impairment of the brain microstructure has been scarcely elucidated. Using multiparametric quantitative (q) magnetic resonance imaging MRI, we aimed to investigate diffuse impairment of the microstructural tissue integrity in MRI-negative focal epilepsy patients.
Methods: 27 MRI-negative patients with focal epilepsy (mean age 33.1 ± 14.2 years) and 27 matched healthy control subjects underwent multiparametric qMRI including T1, T2, and PD mapping at 3 T. After tissue segmentation based on synthetic anatomies, mean qMRI parameter values were extracted from the cerebral cortex, the white matter (WM) and the deep gray matter (GM) and compared between patients and control subjects. Apart from calculating mean values for the qMRI parameters across the respective compartments, voxel-wise analyses were performed for each tissue class.
Results: There were no significant differences for mean values of quantitative T1, T2, and PD obtained from the cortex, the WM and the deep GM between the groups. Furthermore, the voxel-wise analyses did not reveal any clusters indicating significant differences between patients and control subjects for the qMRI parameters in the respective compartments.
Conclusions: Based on the employed methodology, no indication for an impairment of the cerebral microstructural tissue integrity in MRI-negative patients with focal epilepsy was found in this study. Further research will be necessary to identify relevant factors and mechanisms contributing to microstructural brain tissue damage in various subgroups of patients with epilepsy.
Highlights
• The goal was to assess the intra- and inter-scanner reproducibility of qMRI data.
• Mean scan-rescan variations were not exceeding 2.14%.
• Mean inter-scanner model deviations were not exceeding 5.21%.
• Provided that identical acquisition sequences are used, discrepancies between qMRI data acquired with different scanner models are low.
Abstract
Background: Quantitative MRI (qMRI) techniques allow assessing cerebral tissue properties. However, previous studies on the accuracy of quantitative T1 and T2 mapping reported a scanner model bias of up to 10% for T1 and up to 23% for T2. Such differences would render multi-centre qMRI studies difficult and raise fundamental questions about the general precision of qMRI. A problem in previous studies was that different methods were used for qMRI parameter mapping or for measuring the transmitted radio frequency field B1 which is critical for qMRI techniques requiring corrections for B1 non-uniformities.
Aims: The goal was to assess the intra- and inter-scanner reproducibility of qMRI data at 3 T, using two different scanner models from the same vendor with exactly the same multiparametric acquisition protocol.
Methods: Proton density (PD), T1, T2* and T2 mapping was performed on healthy subjects and on a phantom, performing each measurement twice for each of two scanner models. Although the scanners had different hardware and software versions, identical imaging sequences were used for PD, T1 and T2* mapping, adapting the codes of an existing protocol on the older system line by line to match the software version of the newer scanner. For T2-mapping, the respective manufacturer’s sequence was used which depended on the software version. However, system-dependent corrections were carried out in this case. Reproducibility was assessed by average values in regions of interest.
Results: Mean scan-rescan variations were not exceeding 2.14%, with average values of 1.23% and 1.56% for the new and old system, respectively. Inter-scanner model deviations were not exceeding 5.21% with average values of about 2.2–3.8% for PD, 2.5–3.0% for T2*, 1.6–3.1% for T1 and 3.3–5.2% for T2.
Conclusions: Provided that identical acquisition sequences are used, discrepancies between qMRI data acquired with different scanner models are low. The level of systematic differences reported in this work may help to interpret multi-centre data.