Oral presentation: 23rd World Congress of the World Society of Cardio-Thoracic Surgeons. Split, Croatia. 12-15 September 2013.
Background: Partial upper sternotomy (PUS) is established less invasive approach for single and double valve surgery. Reports of aortic surgery performed through PUS are rare.
Methods: The records of 52 patients undergoing primary elective surgery on the proximal aorta through PUS between 2005 and 2011 were reviewed. Patients mean age was 57 years, 35% were in NYHA Class III or IV, 59% had recent cardiac decompensation, and 17% had pulmonary hypertension. The PUS was taken down to the 4th left intercostal space in 44 patients (85%).
Results: No conversion to full sternotomy was necessary. The aortic cross-clamp, cardiopulmonary bypass and operative times averaged 136 ± 20 min., 186 ± 36 min. and 327 ± 83 min., respectively. In eight patients, the right axillary artery was cannulated for establishing cardiopulmonary bypass; the others were cannulated centrally. All patients except one received a procedure on the ascending aorta, either replacement in 30 (58%) or reduction aortoplasty in 21 (40%). Aortic root replacement was additionally performed in 31 patients (60%), including David in 20 (38%) and Ross procedure in 6 (11.5%). The aortic arch was replaced either partially in 5 (10%) or totally in 3 (6%) patients, in moderate hypothermia employing antegrade cerebral perfusion. Additional procedures, included mitral valve repair in 15 (29%) patients and coronary grafting. Ventilation time, intensive care unit and hospital stay averaged 17 ± 12 hours, 2 ± 1, and 11 ± 9 days. Chest drainage was 470 ± 380 ml/24 hours. Permanent neurologic deficit did not occur. Wound dehiscence was observed in a single patient (2%). Thirty-day and hospital mortality were not observed.
Conclusions: Less invasive surgery on the aortic root, ascending aorta and aortic arch can be performed safely and reproducibly. Potential benefits include a minimized risk of wound dehiscence and reduced postoperative bleeding. The PUS does not compromise the quality of the operation.
Background: The aim of this study was to evaluate the longer-term results of bicuspid aortic valve (BAV) repair with or without aortic root replacement. Methods: From 1999 to 2017, 142 patients with or without aortic root dilatation who underwent repair of a regurgitant BAV were included in the study. Ninety-four patients underwent isolated BAV repair (Group 1; median age 43 years) and 48 patients underwent valve-sparing aortic root replacement plus BAV repair (aortic valve reimplantation—Group 2; median age 48 years). Median clinical follow-up time was 5.9 years (range 0.5–15) in Group 1 and 3 years (range 0.5–16) in Group 2, respectively. Results: In-hospital mortality was 1% in Group 1, and 2% in Group 2 (p = .6). The 5- and 10-year survival was 93 ± 2.9% and 81 ± 5.8% in Group 1 and 96 ± 3.1% and 96 ± 3.1% in Group 2, respectively (p = .31). Eleven patients of Group 1 (1.7%/patient-year) and five patients of Group 2 (2.2%/patient-year) underwent reoperation of the aortic valve (p = .5). The 5- and 10-year freedom from reoperation were 93.0 ± 2.1% and 77.1 ± 7.1% in Group 1 and 93.0 ± 5.0% and 76.7 ± 9.6% in Group 2 (p = .83), respectively. At the latest follow-up, only two patients of Group 1 and 1 patient of Group 2 had AV regurgitation = 2° (p = .7). The cumulative linearized incidence of all valve-related complications (bleeding, stroke, endocarditis, and reoperation) was 2.9%/patient-year in Group 1% and 4%/patient-year in Group 2, respectively (p = .6). Conclusions: Isolated BAV repair and combined aortic valve reimplantation plus BAV repair provide good clinical longer-term outcomes with relatively low reoperation rate and durable valve function.
Biventricular pacing has been suggested in end-stage heart failure. We present a 59-year-old patient undergoing second re-do CABG (coronary artery bypass graft) and carotid artery endarterectomy. Ejection fraction was 15%, QRS-width 175 ms. Following the carotid and CABG procedure, an implanted single-chamber ICD (implantable cardioverter defibrillator) was upgraded to permanent biventricular DDD pacing by implantation of one epicardial left ventricular and one epicardial atrial electrode. At follow-up two months postoperatively ejection fraction had significantly improved to 45%, the patient underwent stress test with adequate load and reported a good quality of life.