Background: Phobic patients avoid dental treatment impairing their oral health and making it challenging to offer them prosthetic rehabilitation. This study evaluated patients’ experience of implant-supported prosthetic treatment after implantation performed under general anaesthesia due to dental phobia and severe pharyngeal reflexes (SPR). The effect of gender, age and location of implantation on patient satisfaction was tested.
Methods: Two hundred five patients underwent implantation under general anesthesia both in maxilla and mandible, respectively. After a trans-gingival healing period of 6–8 weeks, fixed implant bridges were inserted. Patients completed oral health impact profile questionnaire (OHIP-14). An additional set of six special questions was also developed and considered. Analysis of the OHIP-14 total score was made using logistics regression. Wald chi-square test was used to analyse the effect of age, gender and location of implantation. Effect sizes were estimated as odds-ratios and associated 95% Wald confidence intervals.
Results: Eighty two of 205 patients were included after prosthetic treatment. After start, 38 patients were excluded (4 died and 34 couldn’t be reached). OHIP-14-analyses were made by 43 patients (30–90 years). 67% of patients were totally satisfied with the whole implant rehabilitation (scoring 0). Mean of total score was 2.5. Only age affected significantly (p = 0.014) patients satisfaction. The obtained data indicate that younger patients (30–64 years) especially women are less satisfied (4.95) than older patients (0.3) for age group (65–90 years).Special questions’ data showed that 94.5% were satisfied with their treatment. 77.3% continued regular check-up after treatment and 96.9% would undergo the same treatment again. 95.5% would recommend implants to a friend of colleague.
Conclusion: Gender and location of implantation have no significant influence on patient satisfaction. Younger patients especially women are less satisfied than older patients. Phobic patients are totally satisfied with implant rehabilitation under general anaesthesia which means that this treatment can be considered as a treatment of choice giving these patients the same opportunity like others to improve their oral health and well-being.
Purpose: All-ceramic restorations required extensive tooth preparation. The purpose of this in vitro study was to investigate a minimally invasive preparation and thickness of monolithic zirconia crowns, which would provide sufficient mechanical endurance and strength.
Materials and methods: Crowns with thickness of 0.2 mm (group 0.2, n=32) or of 0.5 mm (group 0.5, n=32) were milled from zirconia and fixed with resin-based adhesives (groups 0.2A, 0.5A) or zinc phosphate cements (groups 0.2C, 0.5C). Half of the samples in each subgroup (n=8) underwent thermal cycling and mechanical loading (TCML)(TC: 5℃ and 55℃, 2×3,000 cycles, 2 min/cycle; ML: 50 N, 1.2×106 cycles), while the other samples were stored in water (37℃/24 h). Survival rates were compared (Kaplan-Maier). The specimens surviving TCML were loaded to fracture and the maximal fracture force was determined (ANOVA; Bonferroni; α=.05). The fracture mode was analyzed.
Results: In both 0.5 groups, all crowns survived TCML, and the comparison of fracture strength among crowns with and without TCML showed no significant difference (P=.628). Four crowns in group 0.2A and all of the crowns in group 0.2C failed during TCML. The fracture strength after 24 hours of the cemented 0.2 mm-thick crowns was significantly lower than that of adhesive bonded crowns. All cemented crowns provided fracture in the crown, while about 80% of the adhesively bonded crowns fractured through crown and die.
Conclusion: 0.5 mm thick monolithic crowns possessed sufficient strength to endure physiologic performance, regardless of the type of cementation. Fracture strength of the 0.2 mm cemented crowns was too low for clinical application.
he aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces.
The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was conducted to identify studies on tooth wear against ceramic crowns in posterior region. The selected studies were analyzed in regard to type of crowns, natural antagonist, measuring protocol and outcome. From a yield of 1 000 titles, 43 articles were selected for full-text analysis; finally, no in vitro and only five in vivo studies met the inclusion criteria. As there is heterogeneity in design, used measuring method, ceramics and analysis-form, a meta-analysis was not possible. Results of these studies are very controversial which makes a scientifically valid comparison impossible. This review indicated that some all-ceramic crowns are as wear friendly as metal-ceramic crowns. Up to now, it has been impossible to associate tooth wear with any specific causal agent. The role of ceramic surface treatment that might be responsible for the changing in rate of tooth wear seems undetermined as yet through clinical trials. The literature reveals that studies on this topic are subject to a substantial amount of bias. Therefore, additional clinical studies, properly designed to diminish bias, are warranted.
The aim of this systematic review and meta-analysis was to compare the peri-implant vertical bone loss of immediate loading of implant crowns using the one abutment at one time (AOT) protocol and implants with abutment removal (AR). This systematic review with meta-analysis was reported according to the PRISMA statement, with guidance from the Cochrane Collaboration Handbook. A total of 103 publications were identified in the PubMed database and reference lists of examined articles. After the screening of titles and abstracts, the eligibility of eight full-text articles was assessed. Five studies published between 2010 and 2015 were included in the meta-analysis. There was less peri-implant vertical bone loss at implants using an AOT protocol than at implants using AR protocol (WMD -0.19, 95% CI -0.26 to -0.13; p<0.0001; random-effects model). In conclusion, the use of the AOT protocol with platform-switched Morse implants results in less bone loss than do AR procedures, but this effect may not be clinically relevant. The preservation of marginal bone level achieved with the AOT protocol may not enhance the aesthetics. These results should be interpreted with caution.
Manufacturing processes of custom implant abutments may contaminate their surfaces with micro wear deposits and generic pollutants. Such particulate debris, if not removed, might be detrimental and provoke inflammatory reactions in peri-implant tissues. Although regulatory guidelines for adequate cleaning, disinfection, or sterilization exist, there does not appear to be a consistent application and data on the amount and extent of such contaminants is lacking. The aim of the present in vitro study was to evaluate the quality and quantity of processing-related surface contamination of computer-aided design/computer-aided manufacturing (CAD/CAM) abutments in the state of delivery and after ultrasonic cleaning. A total of 28 CAD/CAM monotype and hybrid abutments were cleaned and disinfected applying a three-stage ultrasonic protocol (Finevo protocol). Before and after cleaning, the chemical composition and the contamination of the abutments were assessed using scanning electron microscopy (SEM), dispersive X-ray spectroscopy(EDX),andcomputer-aidedplanimetricmeasurement(CAPM).Inthedeliverycondition, monotype abutments showed a significantly higher amount of debris compared to hybrid abutments (4.86±6.10% vs. 0.03 ± 0.03%, p < 0.001). The polishing process applied in the laboratory after bonding the hybrid abutment components reduces the surface roughness and thus contributes substantially to their purity. The extent of contamination caused by computer-aided manufacturing of custom abutments can be substantially minimized using a three-stage ultrasonic protocol.
Purpose: Scientific evidence is limited regarding the long-term (>10 years) outcomes of large enough numbers of implants (>500) to allow for reliable comparison of subgroups. The purpose of this study was to analyze the outcomes of dental implants placed in an active University Clinic setting and followed for up to 20 years.
Materials and Methods: Data documenting the implant placement, prosthetic reconstruction, and annual follow-up of patients treated at Frankfurt University were extracted from a Structured Query Language database and patients’ written records and evaluated statistically.
Results: Between April of 1991 and May of 2011, 12,737 ANKYLOS® (DENTSPLY Implants Manufacturing GmbH, Mannheim, Germany) implants were placed in 4,206 patients for a variety of clinical indications. The Kaplan–Meier cumulative survival rate (CSR) was 93.3% after 204 months. Most of the failures (198/1.6%) occurred during the first year after implant placement and before prosthesis delivery. A significantly higher (p < .001) number of implants placed in the mandible and in hard quality bone failed than those placed in the maxilla or in weak and normal quality bone. Female patients had significantly higher CSRs (93.7% 204 months) than male patients (92.8% 204 months/p = .029). The implants showed low rates of peri-implant bone loss after 204 months (horizontal: 21 mm: 85.7%, vertical: 21 mm: 85.2%).
Conclusion: ANKYLOS dental implants followed for up to 20 years have high CSRs and low rates of peri-implant bone loss.
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
Purpose: The aim of this study is to record material- and surface-dependent heat dissipation during the process of inserting implants into native animal bone. Materials and Methods: Implants made of titanium and zirconium that were identical in macrodesign were inserted under controlled conditions into a bovine rib tempered to 37 °C. The resulting surface temperature was measured on two bone windows by an infrared camera. The results of the six experimental groups, ceramic machined (1), sandblasted (2), and sandblasted and acid-etched surfaces (3) versus titanium implants with the corresponding surfaces (4, 5, and 6) were statistically tested. Results: The average temperature increase, 3 mm subcrestally at ceramic implants, differed with high statistical significance (p = 7.163 × 10−9, resulting from group-adjusted linear mixed-effects model) from titanium. The surface texture of ceramic implants shows a statistical difference between group 3 (15.44 ± 3.63 °C) and group 1 (19.94 ± 3.28 °C) or group 2 (19.39 ± 5.73 °C) surfaces. Within the titanium implants, the temperature changes were similar for all surfaces. Conclusion: Within the limits of an in vitro study, the high temperature rises at ceramic versus titanium implants should be limited by a very slow insertion velocity.
Purpose: To evaluate the prevalence of peri‐implantitis (PI) and peri‐implant mucositis (PM) in a long‐term follow‐up with comparison among different PI and PM definitions, and to report on the incidence of PI.
Materials and Methods: In a retrospective clinical study five different PI and PM definitions were applied onto a population with 274 implants 17 to 23 years postimplant placement. Recommendations by the Eighth European Workshop on Periodontology (EWOP) were used as base reference. Clinical and radiological measurements were considered. Risk factors were evaluated in a regression analysis.
Results: After an average observation period of 18.9 years, 40.1% of the implants were diagnosed with PM and 15.0% with PI (Eighth EWOP). PI incidence reached 7.9% on implant level and 13.2% on patient level. Implants diagnosed with PI and progressive bone loss displayed exceptionally vertical bone defect configuration (BDC). Diabetes mellitus, smoking, regular maintenance, or a former periodontal infection did not show significant influence on the prevalence of peri‐implant diseases. Patients with bruxism displayed significantly less PM and PI.
Conclusions: Vertical BDC seems to correspond with active PI, wherefore we estimate such a defining factor of importance. Diagnosis of PM and evaluation of probing pocket depths might be only of descriptive interest as they could lead to false‐positive results.