Objectives: The authors sought to evaluate the performance of the Ranger paclitaxel-coated balloon versus uncoated balloon angioplasty for femoropopliteal lesions at 12 months.
Background: Drug-coated balloons (DCBs) are a promising endovascular treatment option for peripheral artery disease of the femoropopliteal segment, and each unique device requires dedicated clinical study.
Methods: The prospective, randomized RANGER SFA (Comparison of the Ranger™ Paclitaxel-Coated PTA Balloon Catheter and Uncoated PTA Balloons in Femoropopliteal Arteries) study (NCT02013193) enrolled 105 patients with symptomatic lower limb ischemia (Rutherford category 2 to 4) and stenotic lesions in the nonstented femoropopliteal segment at 10 European centers. Seventy-one patients (mean age 68 ± 8 years, n = 53 men) were enrolled in the Ranger DCB arm, and 34 patients (mean age 67 ± 9 years, n = 23 men) were assigned to the control group. Twelve-month analysis included patency, safety, and clinical outcomes and quality-of-life assessments.
Results: The DCB group had a greater primary patency rate at 12 months (Kaplan-Meier estimate 86.4% vs. 56.5%), with a significantly longer time to patency failure (log-rank p < 0.001). The estimated freedom from target lesion revascularization rate was 91.2% in the DCB group and 69.9% in the control group at 12 months, with a significantly longer time to reintervention (p = 0.010). No target limb amputations or device-related deaths occurred in either group.
Conclusions: Twelve-month results show that patency was maintained longer after Ranger DCB treatment than after conventional balloon angioplasty, and this result was associated with a low revascularization rate and good clinical outcomes.
Highlights
• A panel of 20 biomarkers was identified capable of differentiating BD patients from controls.
• Excellent discrimination between established BD patients and controls.
• Good to excellent discrimination between misdiagnosed BD patients and first onset MDD patients.
• Fair to good discrimination between pre-diagnostic BD patients and controls.
• Study demonstrates the potential utility of a protein biomarker panel as a diagnostic test for BD.
Abstract
Background: Bipolar disorder (BD) is a costly, devastating and life shortening mental disorder that is often misdiagnosed, especially on initial presentation. Misdiagnosis frequently results in ineffective treatment. We investigated the utility of a biomarker panel as a diagnostic test for BD.
Methods and findings: We performed a meta-analysis of eight case-control studies to define a diagnostic biomarker panel for BD. After validating the panel on established BD patients, we applied it to undiagnosed BD patients. We analysed 249 BD, 122 pre-diagnostic BD, 75 pre-diagnostic schizophrenia and 90 first onset major depression disorder (MDD) patients and 371 controls. The biomarker panel was identified using ten-fold cross-validation with lasso regression applied to the 87 analytes available across the meta-analysis studies.
We identified 20 protein analytes with excellent predictive performance [area under the curve (AUC) ⩾ 0.90]. Importantly, the panel had a good predictive performance (AUC 0.84) to differentiate 12 misdiagnosed BD patients from 90 first onset MDD patients, and a fair to good predictive performance (AUC 0.79) to differentiate between 110 pre-diagnostic BD patients and 184 controls. We also demonstrated the disease specificity of the panel.
Conclusions: An early and accurate diagnosis has the potential to delay or even prevent the onset of BD. This study demonstrates the potential utility of a biomarker panel as a diagnostic test for BD.