Background: Perioperative anaemia leads to impaired oxygen supply with a risk of vital organ ischaemia. In healthy and fit individuals, anaemia can be compensated by several mechanisms. Elderly patients, however, have less compensatory mechanisms because of multiple co-morbidities and age-related decline of functional reserves. The purpose of the study is to evaluate whether elderly surgical patients may benefit from a liberal red blood cell (RBC) transfusion strategy compared to a restrictive transfusion strategy.
Methods: The LIBERAL Trial is a prospective, randomized, multicentre, controlled clinical phase IV trial randomising 2470 elderly (≥ 70 years) patients undergoing intermediate- or high-risk non-cardiac surgery. Registered patients will be randomised only if Haemoglobin (Hb) reaches ≤9 g/dl during surgery or within 3 days after surgery either to the LIBERAL group (transfusion of a single RBC unit when Hb ≤ 9 g/dl with a target range for the post-transfusion Hb level of 9–10.5 g/dl) or the RESTRICTIVE group (transfusion of a single RBC unit when Hb ≤ 7.5 g/dl with a target range for the post-transfusion Hb level of 7.5–9 g/dl). The intervention per patient will be followed until hospital discharge or up to 30 days after surgery, whichever occurs first. The primary efficacy outcome is defined as a composite of all-cause mortality, acute myocardial infarction, acute ischaemic stroke, acute kidney injury (stage III), acute mesenteric ischaemia and acute peripheral vascular ischaemia within 90 days after surgery. Infections requiring iv antibiotics with re-hospitalisation are assessed as important secondary endpoint. The primary endpoint will be analysed by logistic regression adjusting for age, cancer surgery (y/n), type of surgery (intermediate- or high-risk), and incorporating centres as random effect.
Discussion: The LIBERAL-Trial will evaluate whether a liberal transfusion strategy reduces the occurrence of major adverse events after non-cardiac surgery in the geriatric population compared to a restrictive strategy within 90 days after surgery.
Trial registration: ClinicalTrials.gov (identifier: NCT03369210).
Cholinesterase alterations in delirium after cardiosurgery: a German monocentric prospective study
(2020)
Objectives: Postoperative delirium (POD) is a common complication after elective cardiac surgery. Recent evidence indicates that a disruption in the normal activity of the cholinergic system may be associated with delirium.
Design: Prospective observational study.
Setting: Single-centre at a European academic hospital.
Primary: and secondary outcome measures In our study the enzyme activities of acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) were determined preoperatively as well as on the first and second postoperative day. The confusion assessment method for the intensive care unit was used to screen patients for the presence of POD.
Results: A total of 114 patients were included in the study. POD was associated with a decrease in BChE activity on postoperative day 1 (p=0.03). In addition, patients who developed POD, had significantly lower preoperative AChE activity than patients without POD (p<0.01). Multivariate analysis identified a preoperatively decreased AChE activity (OR 3.1; 95% CI 1.14 to 8.46), anticholinergic treatment (OR 5.09; 95% CI 1.51 to 17.23), elevated European System for Cardiac Operative Risk Evaluation (OR 3.68; 95% CI 1.04 to 12.99) and age (OR 3.02; 95% CI 1.06 to 8.62) to be independently associated with the development of POD.
Conclusions: We conclude that a reduction in the acetylcholine hydrolysing enzyme activity in patients undergoing cardiac surgery may correlate with the development of POD.
Introduction: Gravity plays a pivotal role in the pathogenesis of ventilator-associated pneumonia (VAP) (1). In previous laboratory studies (2) the semi-lateral Trendelenburg position (LTP) hindered gravity-driven pulmonary aspiration and avoided VAP.
Objectives: To determine whether the LTP vs. the semi-recumbent position (SRP) would reduce the incidence of microbiologically confirmed VAP and to appraise patient's compliance and safety.
Methods: We conducted a randomized, single-blind, controlled study in 17 European centers and 1 in North America. A total of 2019 adult patients were screened between 2010 and 2015. 395 patients were randomized - 194 in LTP and 201 in SRP - and analyzed in an intention to treat approach. Patients in LTP were placed in semi-lateral (60°) - Trendelenburg position to achieve an orientation, from the sternal notch toward the mouth, slightly below horizontal, and turned from one side to the other every 6 hours. LTP was encouraged during the first days of mechanical ventilation, but always in compliance with the patient's wish. In the SRP group, the head of the bed was elevated ≥ 30°. Primary outcome was VAP incidence rate, based on quantitative bronchoalveolar lavage fluid culture with ≥ 104 colonyforming units/mL. Secondary outcomes were compliance to the randomized position, length of intubation, duration of intensive care unit and hospital stay, mortality, and adverse events.
Results: The trial was stopped after the planned interim analysis for achieving efficacy endpoints and owing to safety concerns. Patients in the LTP and SRP group were kept in the randomized position for 38 % and 90 % of the study time, respectively (p = 0.001). Yet, during the first 48 hours, LTP patients were kept in the randomized position for 50 % of the study time, and SRP patients for 88 % (p = 0.001). In the LTP, the bed was angulated 5.6° in Trendelenburg; while, the head of the bed was elevated 34.1° in the SRP group. Incidence rates of microbiologically confirmed VAP were 0.88 (1/1136 patient-days; 95 % confidence interval [CI], 0.12-6.25) in the LTP group, and 7.19 (8/1113 patient-days; CI 95 %, 3.60-14.37) in the SRP (p = 0.020), relative risk reduction of 0.12 (95 % CI, 0.01-0.91). No statistically significant differences were observed in durations of mechanical ventilation, intensive care unit and hospital stay, and mortality. Vomiting was more common in LTP patients (8.3 % vs. 2.5 % in the SRP, p = 0.013).
Conclusions: Critically ill patients positioned in the LTP had a statistically significant reduction in the incidence of VAP, compared with those positioned in the SRP. A comprehensive evaluation of potential LTP contraindications is warranted to enhance safety.
Background: Approximately every third surgical patient is anemic. The most common form, iron deficiency anemia, results from persisting iron‐deficient erythropoiesis (IDE). Zinc protoporphyrin (ZnPP) is a promising parameter for diagnosing IDE, hitherto requiring blood drawing and laboratory workup.
Study design and methods: Noninvasive ZnPP (ZnPP‐NI) measurements are compared to ZnPP reference determination of the ZnPP/heme ratio by high‐performance liquid chromatography (ZnPP‐HPLC) and the analytical performance in detecting IDE is evaluated against traditional iron status parameters (ferritin, transferrin saturation [TSAT], soluble transferrin receptor–ferritin index [sTfR‐F], soluble transferrin receptor [sTfR]), likewise measured in blood. The study was conducted at the University Hospitals of Frankfurt and Zurich.
Results: Limits of agreement between ZnPP‐NI and ZnPP‐HPLC measurements for 584 cardiac and noncardiac surgical patients equaled 19.7 μmol/mol heme (95% confidence interval, 18.0–21.3; acceptance criteria, 23.2 μmol/mol heme; absolute bias, 0 μmol/mol heme). Analytical performance for detecting IDE (inferred from area under the curve receiver operating characteristics) of parameters measured in blood was: ZnPP‐HPLC (0.95), sTfR (0.92), sTfR‐F (0.89), TSAT (0.87), and ferritin (0.67). Noninvasively measured ZnPP‐NI yielded results of 0.90.
Conclusion: ZnPP‐NI appears well suited for an initial IDE screening, informing on the state of erythropoiesis at the point of care without blood drawing and laboratory analysis. Comparison with a multiparameter IDE test revealed that ZnPP‐NI values of 40 μmol/mol heme or less allows exclusion of IDE, whereas for 65 μmol/mol heme or greater, IDE is very likely if other causes of increased values are excluded. In these cases (77% of our patients) ZnPP‐NI may suffice for a diagnosis, while values in between require analyses of additional iron status parameters.
In-line filtration of intravenous infusion may reduce organ dysfunction of adult critical patients
(2019)
Background: The potential harmful effects of particle-contaminated infusions for critically ill adult patients are yet unclear. So far, only significant improved outcome in critically ill children and new-borns was demonstrated when using in-line filters, but for adult patients, evidence is still missing.
Methods: This single-centre, retrospective controlled cohort study assessed the effect of in-line filtration of intravenous fluids with finer 0.2 or 1.2 μm vs 5.0 μm filters in critically ill adult patients. From a total of n = 3215 adult patients, n = 3012 patients were selected by propensity score matching (adjusting for sex, age, and surgery group) and assigned to either a fine filter cohort (with 0.2/1.2 μm filters, n = 1506, time period from February 2013 to January 2014) or a control filter cohort (with 5.0 μm filters, n = 1506, time period from April 2014 to March 2015). The cohorts were compared regarding the occurrence of severe vasoplegia, organ dysfunctions (lung, kidney, and brain), inflammation, in-hospital complications (myocardial infarction, ischemic stroke, pneumonia, and sepsis), in-hospital mortality, and length of ICU and hospital stay.
Results: Comparing fine filter vs control filter cohort, respiratory dysfunction (Horowitz index 206 (119–290) vs 191 (104.75–280); P = 0.04), pneumonia (11.4% vs 14.4%; P = 0.02), sepsis (9.6% vs 12.2%; P = 0.03), interleukin-6 (471.5 (258.8–1062.8) ng/l vs 540.5 (284.5–1147.5) ng/l; P = 0.01), and length of ICU (1.2 (0.6–4.9) vs 1.7 (0.8–6.9) days; P < 0.01) and hospital stay (14.0 (9.2–22.2) vs 14.8 (10.0–26.8) days; P = 0.01) were reduced. Rate of severe vasoplegia (21.0% vs 19.6%; P > 0.20) and acute kidney injury (11.8% vs 13.7%; P = 0.11) was not significantly different between the cohorts.
Conclusions: In-line filtration with finer 0.2 and 1.2 μm filters may be associated with less organ dysfunction and less inflammation in critically ill adult patients.
Trial registration: The study was registered at ClinicalTrials.gov (number: NCT02281604).
Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.
Background: The use of cell salvage and autologous blood transfusion has become an important method of blood conservation. So far, there are no clinical data about the performance of the continuous autotransfusion device CATSmart.
Methods: In total, 74 patients undergoing either cardiac or orthopedic surgery were included in this prospective, bicenter and observational technical evaluation to validate red cell separation process and washout quality of CATSmart. The target of red cell separation process was defined as a hematocrit value in the packed red cell unit of 55–75% and of washout quality of 80–100% removal ratio.
Results: Hematocrit values measured by CATSmart and laboratory analysis were 78.5% [71.3%; 84.0%] and 73.7% [67.5%; 75.5%], respectively. Removal ratios for platelets 94.7% [88.2%; 96.7%], free hemoglobin 89.3% [85.2%; 94.9%], albumin 97.9% [96.6%; 98.5%], heparin 99.9% [99.9%; 100.0%], and potassium 92.5% [90.8%; 95.0%] were within the target range while removal of white blood cells was slightly worse 72.4% [57.9%; 87.3%].
Conclusion: The new autotransfusion device enables sufficient red cell separation and washout quality.