Refine
Document Type
- Article (8)
- Conference Proceeding (1)
Has Fulltext
- yes (9)
Is part of the Bibliography
- no (9)
Keywords
- Animal model (1)
- Bone tumor (1)
- CT-guided interventions (1)
- Computed tomography (1)
- Diagnostic accuracy (1)
- Endoscopic retrograde cholangiopancreatography (1)
- Endovascular aortic repair (1)
- First experience with patients (1)
- HCC (1)
- LNS (1)
Institute
- Medizin (9)
The objective of this pilot clinical study was to assess the safety, technical feasibility, pharmacokinetic (PK) profile and tumour response of DC Bead™ with irinotecan (DEBIRI™) delivered by intra-arterial embolisation for the treatment of metastatic colorectal cancer. Eleven patients with unresectable liver metastases from CRC, tumour burden <30% of liver volume, adequate haematological, liver and renal function, performance status of <2 were included in this study. Patients received up to 4 sessions of TACE with DEBIRI at 3-week intervals. Feasibility of the procedure, safety and tumour response were assessed after each cycle. PK was measured after the first cycle. Patients were followed up to 24 weeks. Only mild to moderate adverse events were observed. DEBIRI is a technically feasibile procedure; no technical complications were observed. Average Cmax for irinotecan and SN-38 was 194 ng/ml and 16.7 ng/ml, respectively, with average t½ of 4.6 h and 12.4 h following administration of DEBIRI. Best overall response during the study showed disease control in 9 patients (2 patients with partial response and 7 with stable disease, overall response rate of 18%). Our study shows that transarterial chemoembolisation with irinotecan-loaded DC beads (DEBIRI) is safe, technically feasible and effective with a good PK profile.
Einleitung: Für die meisten Patienten mit HCC ist die LTX die einzige kurative Behandlungsoption. Bei diesen Patienten scheint eine Kontrolle der Erkrankung durch lokale Verfahren im Intervall bis zur LTX zu erreichen zu sein. Als das beste Verfahren gilt die transarterielle Chemoembolisation (TACE). Die Effektivität ist jedoch umstritten. Möglicherweise kann sie aber Patienten startifizieren, die ein hohes Rezidivrisiko haben.
Material und Methoden: Im Zeitraum zwischen 1995 und 2005 wurden n=27 Patienten mit HCC im Alter zwischen 22 und 69 Jahren transplantiert. Hiervon erhielten n=15 Patienten eine Vorbehandlung in Form einer alleinigen TACE oder kombiniert mit PEI [n=1] bzw. LITT [n=1]. Retrospektiv wurde das Gesamtüberleben sowie das „Event-free-survival“ (Rezidiv, Reinfektion und Tod) analysiert.
Ergebnisse: Die mittlere Wartezeit betrug bei Patienten in der TACE-Gruppe 214 Tage, bei Patienten ohne Vorbehandlung 133 Tage. Bei einem mittleren Nachbeobachtungszeitraum von 1097 ± 1193 Tagen für TACE-Patienten und 1674 ± 966 Tagen für non-TACE-Patienten betrug das Überleben für Patienten, die mit TACE vorbehandelt wurden 83,3%, für Patienten, die keine TACE erhielten 86.7% (p=0,5693). Gleiches fand sich für das Event-free-survival (p=0,8823). Das Gesamtüberleben der Patienten, die auf der Warteliste einen Tumorprogress hatten lag bei 77%, während Patienten mit stabiler Tumorgröße oder Regredienz der Tumore ein Überleben von 93% aufwiesen (p=0,0153). Unter TACE-Behandlung zeigten 5/15 Patienten eine zunehmende Anzahl an Herden im histologischen Präparat verglichen mit der Ausgangsbildgebung. Nur bei einem Patienten zeigte sich der Progress der Erkrankung bereits in der präoperativen Bildgebung. Patienten mit einem Progress der Erkrankung hatten ein Gesamtüberleben von 60%, während Patienten mit „stable disease“ oder Rückgang der Herde ein Gesamtüberleben von 100% hatten (p=0,0180).
Schlussfolgerung: Unseren Ergebnisse zufolge ist der Effekt der TACE als Bridgingverfahren auf das Überleben der Patienten fraglich. Allerdings scheint die TACE zur Riskostratifizierung geeignet zu sein. In unserem Patientenkollektiv hatten Patienten, die eine Progredienz der Erkrankung auf der Warteliste zeigten ein signifikant schlechteres Gesamtüberleben. Dies gilt auch bei ausschließlicher Betrachtung der Patienten mit TACE.
Objective: To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT).
Materials and methods: Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures.
Results: The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients.
Conclusion: Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions.
To analyze prospectively the interventional and clinical aspects of computed tomography-guided direct intratumoural injection of a novel chemotherapeutic administration and the parenchymal changes of tumour and necrosis in malignant liver tumours. Eight patients with 17 colorectal liver metastases were treated with a mean of 5.1 injections and nine patients with 13 hepatocellular carcinoma nodules with a mean of 3.1 treatments with computed tomography guided local applications of a novel cisplatin/epinephrine gel. This application provides a higher local and lower systemic drug concentration. Volumes of tumour and necrosis prior and after treatment were measured by computer generated volumetric analysis. Contrast enhanced studies verified pretherapeutic viable tumour volumes with a value of 77.4 ml in the metastases and 29.2 ml in the hepatocellular carcinoma nodules. Intratumoural drug application resulted in a significant increase of necrosis and a decrease in viable tumour volume to be 68.3 ml in metastases and 14.5 ml in hepatocellular carcinoma. Local therapy control rate for the follow up to 6 months was 38 and 71% for the group of metastases and hepatocellular carcinoma, respectively. Direct intratumoural injection of cisplatin/epinepthrine injectable gel is a feasible and good tolerated method and results in the development of a statistically significant increase in necrosis in malignant liver tumours. For hepatocellular carcinoma a higher local therapy control rate compared to colorectal metastases can be reported.
Background and Aims. Systemic treatment with sorafenib has been the standard of care (SOC) in patients with advanced Barcelona Clinic Liver Cancer (BCLC) stage C hepatocellular carcinoma (HCC) for more than a decade. TACE has been reported to allow better local tumor control in selected patients with BCLC stage C HCC. Methods. A retrospective analysis of patients with BCLC stage C HCC that were treated with sorafenib and TACE was conducted; they were compared to BCLC stage C patients treated either with TACE or sorafenib in the same period of time outside a clinical trial. Results. A total of 201 patients with BCLC stage C were identified, who were treated with either sorafenib and TACE (group A; n = 54), sorafenib (group B; n = 82) or TACE (group C; n = 65). No significant difference in baseline characteristics was observed. Time to progression was 7.0 months (95% CI: 4.3–9.7), 4.1 months (95% CI: 3.6–4.7) and 5.0 months (95% CI: 2.9–7.1) in groups A, B and C, respectively, and overall survival was 16.5 months (95% CI: 15.0–18.1), 8.4 months (95% CI: 6.0–10.8) and 10.5 months (95% CI: 7.5–13.6), respectively (group A vs. group B: p < 0.001; group A vs. group C: p = 0.0023). Adverse events of grade 3/4 occurred in 34% of patients in group A. Conclusions. Although sorafenib is a SOC in patients with BCLC stage C HCC, TACE is frequently used as an additional locoregional treatment in selected patients. This combined approach resulted in a significant overall survival benefit in selected patients, although randomized trials have not yet proven this benefit.
Background: Radiofrequency ablation is a minimal invasive therapy in the treatment of bone metastases. In this study we present a new ablation system enabling an ablation in multiple directions and with an adaptable size and shape.
Material and methods: VX-2 tumor was used for the induction of experimental bone metastases in the femur of six New Zealand white rabbits. X-ray imaging as well as CT and MRI scans before and after treatment was carried out. After detecting bone tumor, radiofrequency ablation was performed. The ablation instrument contained a 10 g bipolar, articulated extendable electrode and a proprietary generator with an impedance controlled algorithm. All bones and the soft tissue were examined histologically.
Results: All animals developed local bone tumor. Mean duration until first osteolytic lesions on CT-scans was 48±14 days. The mean lesion area was 26 mm(2). No systemic tumor spread was seen. 6 radiofrequency procedures were carried out with a mean application time of 6 min±2:30 and an average temperature in the region of effect of 55 °C±4. MRI imaging demonstrated an ablation zone of 23±6 mm around the electrode. Histopathology showed an extensive heat necrosis with no remaining tumor cells in the ablation area.
Conclusion: Radiofrequency ablation is a quickly developing treatment option on the field of minimal invasive bone tumor therapy. The electrode enables an ablation adapted to size and shape of the metastases. Further clinical studies are necessary to test and enhance this radiofrequency system.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Stent insertion is an established technique of endoscopic retrograde cholangiopancreatography (ERCP) to treat symptomatic malignant or benign biliary strictures, and stent placement is accomplished by using the over-the-wire (OTW) method. In some cases, however, it might be challenging and sometimes time consuming to pass a complex biliary stricture with the guidewire. Stent-exchange technique with a guidewire left in place during stent removal might therefore be helpful to guarantee successful and time-sparing interventions.
A simple method is presented to remove the stent with the guidewire left in place, using the OTW stent-exchange method in ERCP. This technique simplifies stent OTW exchange by using a simple endoscopy snare. This article is part of an expert video encyclopedia.