Refine
Year of publication
Document Type
- Article (41)
- Review (23)
- Conference Proceeding (7)
Has Fulltext
- yes (71)
Is part of the Bibliography
- no (71)
Keywords
- Immunturbidimetrie (2)
- guidelines (2)
- "alternative" technology (1)
- "conventional" analysis technics (1)
- 18-Hydroxycorticosteron (1)
- 18-OH corticosterone (1)
- Access® immunoassay system (1)
- Access®-Immunoassaysystem (1)
- Akute (1)
- Anämie (1)
- Atomic and Molecular Physics (1)
- Behandlungskontrolle (1)
- Bence Jones (BJ) proteinuria (1)
- Bence Jones-Proteinurie (1)
- Bilirubinbestimmung (1)
- C-reaktive protein (1)
- C-reäktives Protein (1)
- CRP (1)
- CVID (1)
- Cell signalling (1)
- Cytokine (1)
- Differenzierung (1)
- Ektachem® (1)
- Entzündung (1)
- Erprobung (1)
- Erwachsene (1)
- European Society for Immunodeficiencies (ESID) (1)
- German PID-NET registry (1)
- Gesamteiweißbestimmung im Harn (1)
- Haematopoietic stem cells (1)
- Hitachi 705 (1)
- Hormone (1)
- IgG substitution therapy (1)
- Immunfixations-Elektrophorese (1)
- Immunnephelometrie (1)
- Immunonephelometry (1)
- Immunoturbidimetry (1)
- Impräzision (1)
- Inflammation (1)
- Kallestad QM 300 (1)
- Kallestad QM 30 (1)
- Nachteile (1)
- Nebennierenrinden-Adenom (1)
- Nebennierenrinden-Hyperplasie (1)
- Neugeborene (1)
- Non-clear cell renal cell cancer (1)
- PID prevalence (1)
- Pharmaka (1)
- Phase II trial (1)
- Phase-Proteine (1)
- Phospholipasen A2 (1)
- Plasma proteins (1)
- Plasmaprotein analyzer (1)
- Plasmaproteinanalysensysteme (1)
- Plasmaproteinbestimmung im Harn (1)
- Plasmaproteine (1)
- Prostaglandine (1)
- Proteinbestimmung (1)
- Proteinuria (1)
- Proteinurie (1)
- Präsenzdiagnostik (1)
- Prävalenz (1)
- Qualitätssicherung (1)
- RA-1000 (1)
- Randomized trial (1)
- Reflotron® (1)
- Retikulozytenbestimmung (1)
- Richtigkeit (1)
- Richtlinien (1)
- Schilddrüsenfunktion (1)
- Screening (1)
- Self-renewal (1)
- Sensitivität (1)
- Seralyzer-System (1)
- Seralyzer® (1)
- Spezifität (1)
- Sunitinib (1)
- T4-Bestimmung (1)
- T4-analysis (1)
- Temsirolimus (1)
- Teststreifenanalytik (1)
- Tetrahydro-Aldosteron (1)
- Tris-Teepol-Puffer (1)
- Tris-Teepol-buffer (1)
- Tumormarker (1)
- Turbidimetric determination (1)
- Vision® (1)
- Vorteile (1)
- accuracy (1)
- acute phase reactants (1)
- adrenal adenomas (1)
- adults (1)
- advantages and shortcomings (1)
- alternative Analysentechniken (1)
- anemia (1)
- bilirubin determination (1)
- classification (1)
- cytokines (1)
- drugs (1)
- ectosomes (1)
- evaluation (1)
- exosomes (1)
- extracellular vesicles (1)
- hormones (1)
- immunchemische Bestimmungsmethoden (1)
- immunoassay (1)
- immunofixation electrophoresis (1)
- immunoturbidimetric inhibition technique (1)
- immunturbidimetrische Inhibitionstechnik (1)
- imprecision (1)
- konventionelle Analysentechniken (1)
- miRNAs (1)
- microparticles (1)
- microvesicles (1)
- minimal information requirements (1)
- monoclonal antibody (1)
- monoklonale Antikörper (1)
- newborn (1)
- phospholipase A2 (1)
- plasma protein determination in urine (1)
- polyclonal antibody (1)
- polyklonale Antikörper (1)
- predictive value (1)
- prevalence (1)
- primary aldosteronism (1)
- primary immunodeficiency (PID) (1)
- primärer Hyperaldosteronismus (1)
- prostanoids (1)
- prädiktive Werte (1)
- quality assurance (1)
- real time analysis (1)
- registry for primary immunodeficiency (1)
- reproducibility (1)
- response to therapy (1)
- reticulocyte count (1)
- rigor (1)
- screening (1)
- sensitivity (1)
- solid phase reagent chemistry (1)
- specificity (1)
- standardization (1)
- tetrahydroaldosterone (1)
- thyroid functioning (1)
- total protein determination in urine (1)
- total urinary protein (1)
- tumor marker (1)
Institute
- Medizin (58)
- Physik (12)
- Georg-Speyer-Haus (2)
- Biowissenschaften (1)
- Sportwissenschaften (1)
Der Basismechanismus immunchemischer Reaktionen ist die Antigen-Antikörper-Reaktion. Die nachzuweisenden Substanzen haben in der Bestimmungsreaktion Antigen-Funktion. Die zur Bestimmung der Substanz
im Test eingesetzten Antikörper können polyklonalen oder monoklonalen Ursprungs sein.
Polyklonal gebildete Antikörper werden technisch gewonnen durch die Reinigung der Immunglobulinfraktion immunisierter Tiere. Trotz mehrerer Reinigungsschritte wird vielfach nicht ein spezifischer Antikörper gewonnen, sondern eine heterogene Antikörperfraktion, die neben dem spezifischen Antikörper weitere Antikörper mit unterschiedlicher Affinität Avidität und Spezifität gegen die immunchemisch zu analysierende Substanz enthält.
Die technische Gewinnung monoklonaler Antikörper verläuft im ersten Schritt ähnlich der auf polyklonalem Wege; ein Tier wird immunisiert mit dem immundiagnostisch zu bestimmenden Antigen. Es wird jedoch nachfolgend nicht Blut des immunisierten Tieres zur Antikörpergewinnung entnommen, sondern die MHz. In vitro werden im nächsten Schritt Antigen-sensibilisierte B-Lymphozyten aus der Milz mit Myelomzellen der Maus unter Bildung von Hybridzellen fusioniert. Die Hybridzellen werden selektioniert und diejenigen cloniert, die den gewünschten spezifischen Antikörper bilden. Auf diesem Wege können Antikörper einheitlicher Affinität, Avidität und Spezifität in größeren Mengen gewonnen werden.
Die Vor- und Nachteile poly- und monoklonal gebildeter Antikörper für immunchemische Tests werden dargestellt.