82.80.Bg Chromatography
Refine
Year of publication
- 2010 (1)
Document Type
- Doctoral Thesis (1)
Language
- English (1)
Has Fulltext
- yes (1)
Is part of the Bibliography
- no (1)
Keywords
Institute
- Pharmazie (1)
Top-down and bottom-up approaches are the general methods used to analyse proteomic samples today, however, the bottom-up approach has been dominant in the last decade. Establishing a bottom-up method involves not only the choice of adequate instruments and the optimisation of the experimental parameters, but also choosing the right experimental conditions and sample preparation steps. LC-ESI MS/MS has widely been used in this field due to its advanced automation. The primary objective of the present study was to establish a sensitive high-throughput nLC-MALDI MS/MS method for the identification and characterisation of proteins in biological samples. The method establishment included optimisation and validation of parameters such as the capillaries in the HPLC systems, gradient slopes, column temperature, spotting frequencies or the MS and MS/MS acquisition methods. The optimisation was performed using two HPLC-systems (Agilent 1100 series and Proxeon Easy nLC system), three spotters and the 4800 MALDI-TOF/TOF analyzer. Furthermore, samples preparation protocols were modified to fit to the established nLCMALDI- TOF/TOF-platform. The potentials of this method was demonstrated by the successful analysis of complex protein samples isolated from lipid particles, pre-adipocytes/adipocytes tissues, membrane proteins and proteins pulled-down from protein-proteins interaction studies. Despite the small amount of proteins in the lipid particles or oil bodies, and the challenges encountered in studying such proteins, 41(6 novel + 14 mammal specific + 21 visceral specific) proteins were added to the already existing proteins of the secretome of human subcutaneous (pre)adipocytes and 6 novel proteins localised in the yeast lipid particles. Protein-protein interaction studies present another area of application. Here the analytical challenges are mostly due to the loss of binding partner upon sample clean-up and to differentiate from non-specific background. Novel interaction partners for AF4•MLL and AF4 protein complex were identified. Furthermore, a novel sample protocol for the analysis of membrane proteins, based on the less specific protease, elastase, was established. Compared to trypsin, a higher sequence coverage and higher coverage of the transmembrane domains were achieved. The use of this enzyme in proteomics has been limited because of its non specific cleavage. However, from the results obtained in these studies, elastase was found to cleave preferentially at the C-terminal site of the amino acids AVLIST. The advantage of the established protocol over conventional protocols is that the same enzyme can be used for shaving of the soluble dormains of intact proteins in membranes and the digestion of the hydrophobic domain after solubilisation. Furthermore, the solvents used are compatible with the nLC-MALDI method setup. In addition, it was also shown that for less specific enzymes, a higher mass accuracy is required to reduce the rate of false positive identifications, since current search engines are not perfectly adapted for these types of enzymes. A brief statistical analysis of the MS/MS data obtained from the LC-MALDI TOF/TOF system showed that for less specific enzymes, under high-energy collision conditions, approximately 43 % of the fragment ions could not be matched to the known y- b type ions and their resultant internal fragments. This limitation greatly influenced the search results. However, this limitation can be overcome by modifying the N-terminal amino acids with basic moieties such as TMT. The use of elastase as a digestion enzyme in proteomic workflow further increased the complexity of the sample. Therefore, orthogonal multidimensional separation was necessary. Offgel-IEF was used as the separation technique for the first dimension. Here peptides are separated according to the pI. However, the acquired samples could not be loaded to the nLC due to the high viscosity of the concentrated samples when using the standard protocol. In order to achieve compatibility of the Offgel-IEF to the nLC-MALDI-TOF/TOF-platform, the separation protocol of the Offgel-IEF was modified by omitting the glycerol, which was the cause of the viscous solution. The novel glycerol free protocol is advantageous over the conventional method because the samples could directly be picked-up and loaded onto the pre-column without resulting in an increase in back pressure or a subsequent pre-column clogging. The glycerol free protocol was then assessed using purple membrane and membrane fraction of C. glutamicum. The results obtained were comparable to those applied in published reports. Therefore, the absence of glycerol did not affect the separation efficiency of the Offgel-IEF. In addition the applicability of elastase and the glycerol free Offgel-IEF for quantitation of membrane proteins was assessed. Most of the unique peptides identified were in the acidic region and 85 % were focused only into one fraction and approximately 95 % in only two fractions. These results are in accordance with previously published results (Lengqvist et al., 2007). When compared with theoretical digests of the proteins identified in this study, it can be concluded that basic moiety (TMT) on the peptide backbone, did not affect the separation efficiency of the Offgel-IEF. In an applied study, changes in the protein content of yeast strain grown in two different media were relatively quantified. For example, prominent proteins, such as the hexose tranporter proteins responsible for transporting glucose accross the membrane, were successfully quantified. Last but not least, the nLC-MALDI-TOF/TOF platform also served as a basis for the development of a high-throughput method for the identification of protein phosphorylation. The establishment of such a method using MALDI has been challenging due to the lack of sensitive matrices, such as CHCA for non-modified peptides, which exhibit a homogenous crystallisation and thus yield stable signal intensity over a long period of time in an automated setup. The first step of this method was the establishment of a matrix/matrix mixture with better crystal morphology and higher analyte signal intensity than the matrix of choice, i.e. DHB. From MS and MS/MS measurements of standard phosphopeptides, a combination of FCCA and CHAC in a 3:1 ratio and 3 mM NH4H2PO4 facilitated high analyte signal intensities and good fragmentation behaviour. Combining a custom-packed biphasic column for the enrichment of phosphopeptides, the applicability of the matrix mixture was assessed in anautomated phosphopeptide analysis using standard phosphopeptides spiked to a 20-fold excess BSA digest. These analyses showed that this method is reproducibile and both flow throughs can be analysed. Applying the method to the analysis of 2 standard phosphoproteins, alpha/beta-casein, and a leukemia related protein, ENL, 13 phosphopeptides from both alpha/beta-Casein and 13 phosphopeptides with 6 phosphorylation sites from the ENL were identified. As a general conclusion, it can be stated that the nLC-MALDI-TOF/TOF method established here in various modifications for different analytical purposes is a robust platform for proteomic analyses.