Refine
Document Type
- Preprint (24)
- Article (6)
- Conference Proceeding (1)
- Working Paper (1)
Language
- English (32)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- Aortic arch replacement (1)
- Aortic dissection (1)
- Aortic valve sparing (1)
- Charge fluctuations (1)
- David technique (1)
- QGP (1)
- Relativistic heavy-ion collisions (1)
Institute
- Physik (31)
- Frankfurt Institute for Advanced Studies (FIAS) (1)
- Medizin (1)
The transverse mass mt distributions for deuterons and protons are measured in Pb+Pb reactions near midrapidity and in the range 0<mt–m<1.0 (1.5) GeV/c2 for minimum bias collisions at 158A GeV and for central collisions at 40 and 80 A GeV beam energies. The rapidity density dn/dy, inverse slope parameter T and mean transverse mass <mt> derived from mt distributions as well as the coalescence parameter B2 are studied as a function of the incident energy and the collision centrality. The deuteron mt spectra are significantly harder than those of protons, especially in central collisions. The coalescence factor B2 shows three systematic trends. First, it decreases strongly with increasing centrality reflecting an enlargement of the deuteron coalescence volume in central Pb+Pb collisions. Second, it increases with mt. Finally, B2 shows an increase with decreasing incident beam energy even within the SPS energy range. The results are discussed and compared to the predictions of models that include the collective expansion of the source created in Pb+Pb collisions.
Background: This single center study compares the different surgical techniques used in the treatment of acute aortic dissection type A (AADA) analyzing the influence of the extent of the surgical approach on outcome.
Methods: From 1988 to 2012, 407 patients were operated for AADA. The cohort was divided into subgroups according to the surgical approach. These groups were compared with the supracommissural replacement group (SCR; n = 141). Groups included aortic valve sparing techniques (AVS; n = 29), Composite replacement (COMP; n = 119), COMP with total arch replacement (COMP+TAR; n = 27) and SCR with TAR (n = 75).
Results: Compared to SCR alone, operation (p = 0.005), bypass-, cross-clamp and circulatory arrest times were longer in SCR + TAR (all p < 0.001). Moreover, operation, bypass and cross clamp times were longer in COMP+TAR (p = 0.003, p = 0.002 and p < 0.001 respectively). COMP alone and AVS required longer cross-clamp time, too (p < 0,001 and p = 0.002, respectively). Overall 30-day mortality was 21% with the observed lowest rate after AVS (14%, SCR 18%, COMP 25%) but differences in 30-day mortality were not statistically significant. The estimated 10-year survival was 42%, especially AVS demonstrated a good 10-year survival (69%). David technique was superior to Yacoub technique concerning incidence of redo interventions (p = 0.036). Risk factors for early mortality included age, circulatory arrest, general malperfusion, bypass and operation time. Circulatory arrest per se was revealed as risk factor for long-term survival.
Conclusions: Within our single center retrospective study concomitant aortic root repair or aortic arch replacement for AADA demonstrated acceptable early and long-term survival. Circulatory arrest, long bypass and operation times per se might be important risk factors for early mortality. AVS techniques can be performed safely and have good outcomes in acute aortic dissection repair.