Refine
Document Type
- Conference Proceeding (13)
- Article (4)
- diplomthesis (1)
- Doctoral Thesis (1)
Has Fulltext
- yes (19)
Is part of the Bibliography
- no (19)
Keywords
- Emittanz (1)
- Gabor lens (1)
- Gabor-Linse (1)
- Ionenoptik (1)
- Ionenstrahl (1)
- RFQ (1)
- RFQ-Beschleuniger (1)
- Raumladungskompensation (1)
- Raumladungslinse (1)
- Strahldiagnose (1)
Institute
- Physik (19)
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.
Since the last 20 years, modern heuristic algorithms and machine learning have been increasingly used for several purposes in accelerator technology and physics. Since computing power has become less and less of a limiting factor, these tools have become part of the physicist community's standard toolkit [1][2] [3] [4] [5]. This paper describes the construction of an algorithm that can be used to generate an optimised lattice design for transfer lines under the consideration of restrictions that usually limit design options in reality. The developed algorithm has been applied to the existing SIS18 to HADES transfer line in GSI.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.
This novel kind of neutron beam facility will provide 1 ns short neutron pulses with an approximately thermal energy distribution around 30 keV. The pulse repetition rate will be up to 250 kHz, the total proton number per pulse will be up to 6×1010 in the final stage, starting with a p – source current of 200 mA. A second target station will allow n – activation experiments by cw beam operation. An intense 2 MeV proton beam will drive a neutron source by the 7 Li (p,n) 7 Be reaction. The facility is under construction at the physics experimental hall of the J.W. Goethe – University. The 1m thick concrete tunnel was installed in 2009. In 2011 all rf amplifiers will be delivered and installed. Successful 200 mA proton source experiments in 2010 at a test stand will be followed by experiments on the 120 kV FRANZ terminal in 2011. The 250 kHz, 100 ns chopper in front of the rf linac is under construction, while the 2 MeV bunch compressor design was finished and the technical design of all components has started. The main accelerator cavity is under construction. First 2 MeV beam tests are expected for end of 2012.
Influence of space charge fluctuations on the low energy beam transport of high current ion beams
(2000)
For future high current ion accelerators like SNS, ESS or IFMIF the beam behaviour in low energy beam transport sections is dominated by space charge forces. Therefore space charge fluctuations (e. g. source noise) can drastically influence the beam transport properties of the low energy beam transport section. Losses of beam ions and emittance growth are the most severe problems. For electrostatic transport systems either a LEBT design has to be found which is insensitive to variations of the space charge or the origin of the fluctuations has to be eliminated. For space charge compensated transport as proposed for ESS and IFMIF the situation is different: No major influence on beam transport is expected for fluctuations below a cut-off frequency given by the production rate of the compensation particles. Above this frequency the fluctuations can not be compensated by particle production alone, but redistributions of the compensation particles helps to compensate the influence of the fluctuations. Above a second cut-off frequency given by the density and the temperature of the compensation particles their redistribution is too slow to reduce the influence of the space charge fluctuations. Transport simulations for the IFMIF injector including space charge fluctuations will be presented together with a determination of the cut-off frequencies. The results will be compared with measurements of the rise time of space charge compensation.
The determination of the beam emittance using conventional destructive methods suffers from two main disadvantages. The interaction between the ion beam and the measurement device produces a high amount of secondary particles. Those particles interact with the beam and can change the transport properties of the accelerator. Particularly in the low energy section of high current accelerators like proposed for IFMIF, heavy ion inertial fusion devices (HIDIF) and spallation sources (ESS, SNS) the power deposited on the emittance measurement device can lead to extensive heat on the detector itself and can destruct or at least dejust the device (slit or grit for example). CCD camera measurements of the incident light emitted from interaction of beam ions with residual gas are commonly used for determination of the beam emittance. Fast data acquisition and high time resolution are additional features of such a method. Therefore a matrix formalism is used to derive the emittance from the measured profile of the beam [1,2] which does not take space charge effects and emittance growth into account. A new method to derive the phase space distribution of the beam from a single CCD camera image using statistical numerical methods will be presented together with measurements. The results will be compared with measurements gained from a conventional Allison type (slit-slit) emittance measurement device.
Intense ion beams with small phase space occupation (high brilliance) are mandatory to keep beam losses low in high current injector accelerators like those planned for FAIR. The low energy beam transport from the ion source towards the linac has to keep the emittance growth low and has to support the optimization of the ion source tune. The Frankfurt Neutron Source Facility FRANZ is currently under construction. An intense beam of protons (2 MeV, 200 mA) will be used for neutron production using the Li7(p,n)Be7 reaction for studies of the astrophysical s-process. A collimation channel, which can be adjusted to allow the transport of beams with a certain beam emittance, is an ideal tool to optimize the ion source tune in terms of beam brightness. Therefore a collimation channel in the Low Energy Beam Transport section will be used. Through defined apertures and transversal phase space rotation using focusing solenoids the beam halo as well as unwanted H2+ and H3+ fractions will be cut. Theoretical studies which were carried out so far and a first design of the setup will be presented.
The ARMADILLO bunch compressor currently being designed at IAP is capable of reaching a longitudinal pulse compression ratio of 45 for proton beams of 150 mA at 2 MeV. It will provide one nanosecond proton pulses with a peak current of 7.7 A. The system guides nine linacμbunches deflected by a 5 MHz rf kicker and uses four dipole magnets - two homogeneous and two with field gradients - to merge them on the target. For longitudinal focusing and an energy variation of ±200 keV two multitrack rf cavities are included. ARMADILLO will be installed at the end of the Frankfurt Neutron Source FRANZ making use of the unique 250 kHz time structure. This contribution will provide an overview of the layout of the system as well as recent advances in component design and beam dynamics of the compressor.